SMC Corporation of America
Elite Part Number Search
Search Results "XLA-50-M9NB"

VAC, 50/60 Hz XLA 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz U XL XL 5 24 VDC 6 12 VDC S type: Not available for AC.

VAC, 50/60 Hz XLA 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz U XL XL 5 24 VDC 6 12 VDC S type: Not available for AC.

, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) 420, 440, 480 VAC (50 Hz) 420 to 520 VAC (60 Hz) 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 380, 400, 415 VAC (50 Hz) 380 to 400, 400 to 415, 415 to 440 VAC (60 Hz) 440, 460 VAC (50 Hz) 440 to 460, 460 to 500 VAC (60 Hz) Outlet voltage Symbol 500 1 500 VA 100 VAC (50 Hz) 100, 110 VAC (60 Hz) 1000 2 1 kVA Singlephase 2000 2 kVA 3 4 9 200 VAC (50 Hz

Indicator: 6 High Vacuum Angle Valve Series XLA, XLAV Dimensions (mm) 1in = 25.4mm (b) XLA/Air operated type C D E C E E Fn (KF flange) Fd (K flange) (a) (c) Heater (optional) H B G A A (mm) H 40 G 17 26 41 52 70 83 Fd Fn 30 40 55 75 87 114 D 1 1 2 2 3 3 C 38 48 66 79 100 117 E Note 1) B 103 113 158 170 196 235 A 40 50 65 70 88 90 Model XLA-16 XLA-25 XLA-40 XLA-50 XLA-63 XLA-80 12 11 11

Indicator: 6 High Vacuum Angle Valve Series XLA, XLAV Dimensions (mm) 1in = 25.4mm (b) XLA/Air operated type C D E C E E Fn (KF flange) Fd (K flange) (a) (c) Heater (optional) H B G A A (mm) H 40 G 17 26 41 52 70 83 Fd Fn 30 40 55 75 87 114 D 1 1 2 2 3 3 C 38 48 66 79 100 117 E Note 1) B 103 113 158 170 196 235 A 40 50 65 70 88 90 Model XLA-16 XLA-25 XLA-40 XLA-50 XLA-63 XLA-80 12 11 11

0.28 5 XLA-25-2 50 121 0.47 14 B XLA-40-2 65 171 1.1 45 XLA-50-2 70 185 1.8 80 XLA-63-2 88 212 3.1 160 A XLA-80-2 90 257 5.1 200 *1 The same for all series Minimal outgassing Low outgassing makes it possible to use a lower capacity pump and also shorten exhaust time.

Flange Size: 16, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: B (1pc, Valve Open)

Flange Size: 40, Flange Type: KF(NW), Port Direction: G (w/Indicator, Rear Flange Surface), Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: B (1pc, Valve Open)

Flange Size: 50, Flange Type: KF(NW), Port Direction: G (w/Indicator, Rear Flange Surface), Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: B (1pc, Valve Open)

Flange Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: B (1pc, Valve Open)

Flange Size: 25, Flange Type: KF(NW), Port Direction: A (w/Indicator, Flange Side), Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: B (1pc, Valve Open)

Flange Size: 16, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 1pc, Valve Open, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -

Flange Size: 40, Flange Type: KF(NW), Port Direction: w/Indicator, Rear Flange Surface, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 1pc, Valve Open, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -

Flange Size: 50, Flange Type: KF(NW), Port Direction: w/Indicator, Rear Flange Surface, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 1pc, Valve Open, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -

Flange Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 1pc, Valve Open, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -

Flange Size: 25, Flange Type: KF(NW), Port Direction: w/Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 1pc, Valve Open, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -

-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.