Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure
Main Body Shape: Unit, Additional Function: -, Ultimate Vacuum(kPa): -74, Air Consumption Flow Rate(l/min): 12, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø4, Application: Individual Item, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port
state (AMH) Element initial state (AMH) 0.12 P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa 0.12 P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa Pressure drop (MPa) Pressure drop (MPa) 0.10 0.10 0.08 0.08 0.06 0.06 0.04 0.04 P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa 0.02 0.02 0 0 0 1200 900 600 300 Inlet air flow rate (L/min [ANR]) 0 800 600 400 200 Inlet air flow rate
state (AMH) Element saturated state (AFM, AFD) Element initial state (AFM, AFD) P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa 0.12 0.12 P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa Pressure drop (MPa) Pressure drop (MPa) 0.10 0.10 0.08 0.08 0.06 0.06 0.04 0.04 P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa 0.02 0.02 100 200 300 400 0 400 800 1200 1600 0 Inlet air flow rate
= 1.0 MPa P1 = 0.3 MPa P1 = 0.7 MPa P1 = 0.5 MPa P1 = 0.1 MPa P1 = 0.5 MPa P1 = 0.3 MPa 0.08 0.08 P1 = 0.7 MPa Pressure drop [MPa] Pressure drop [MPa] P1 = 1.0 MPa 0.06 0.06 P1 = 0.1 MPa 0.04 0.04 0.02 0.02 0 0 0 500 1500 1000 Flow rate [L/min (ANR)] 0 2000 1000 4000 3000 Flow rate [L/min (ANR)] AF40-D Rc1/2 AF40-06-D Rc3/4 0.1 0.1 P1 = 0.7 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa P1 =
P1 = 0.7 MPa P1 = 0.7 MPa 0.08 0.08 P1 = 0.5 MPa P1 = 0.3 MPa Pressure drop (MPa) Pressure drop (MPa) P1 = 0.1 MPa P1 = 0.5 MPa P1 = 0.1 MPa 0.06 0.06 P1 = 0.3 MPa Maintenance 0.04 0.04 F.R.L. Warning 0.02 0.02 AV 1.
Area: (800) 258-9200-www.stevenengineering.com P1 = 0.8MPa 1 0.9 0.8 0.7 0.6 0.5 1 0.9 0.8 0.7 0.6 0.5 P1 = 0.6MPa Ex. 2 P1 = 0.5MPa P1 = 0.4MPa 0.4 0.4 P1 = 0.3MPa Ex. 1 0.3 0.3 P1 = 0.2MPa 0.2 0.2 P1 = 0.1MPa 0.1 0.1 0.001 0.04 0.03 0.02 0.01 0.004 0.003 0.002 0.1 Pressure difference P [MPa] Graph (2) Flow characteristics line Example 1) Obtain the pressure difference when water 15 [l/
55 72.5 77.5 93 98 98 L1 28 41.5 55 55 72.5 77.5 93 98 98 L1 41.5 55 55 72.5 77.5 93 L2 43 57 57 75 80 96 L1 41.5 55 55 72.5 77.5 93 L2 57 74 74 95 102 124 L1 41.5 55 55 72.5 77.5 93 L2 61 76 76 99 104 124 AC10B AC20B AC25B AC30B AC40B AC40B-06 AC50B AC55B AC60B SV TV S V T L3 57 74 74 95 102 Attachment Model L1 41.5 55 55 72.5 77.5 L2 43 57 57 75 80 L1 41.5 55 55 72.5
P1 = 0.7 MPa P1 = 0.7 MPa 0.08 0.08 P1 = 0.5 MPa P1 = 0.3 MPa Pressure drop (MPa) Pressure drop (MPa) P1 = 0.1 MPa P1 = 0.5 MPa P1 = 0.1 MPa 0.06 0.06 P1 = 0.3 MPa Maintenance 0.04 0.04 F.R.L. Warning 0.02 0.02 AV 1.
P1 = 0.7MPa 0.08 0.08 P1 = 0.7MPa P1 = 0.5MPa P1 = 0.3MPa Pressure drop MPa Pressure drop MPa P1 = 0.1MPa P1 = 0.5MPa 0.06 0.06 P1 = 0.1MPa P1 = 0.3MPa 0.04 0.04 Maintenance Warning 1.
IFW550 0.10 P1 = 0.6 MPa P1 = 0.5 MPa P1 = 0.4 MPa P1 = 0.3 MPa 0.08 Pressure drop (MPa) P1 = 0.2 MPa 0.06 P1 = 0.1 MPa Component Parts 0.04 No. Description Material Description Material No.
(P1+0.1013) l/min(ANR) Calculation by effective area Q=109.6S(P1+0.1013) l/min(ANR) gP(P2+0.1013)l/min(ANR) Saturated Steam How to Read the Graph In the sonic flow region: For a flow of 15kg/h Orifice 4.5 valve(VX2m3mS)...P1 0.15MPa Orifice 3 valve(VX2m2mS)...P1 0.37MPa Orifice 2 valve(VX211mS)...P1 0.82MPa Heat content will differ somewhat depending upon the pressure P1, in the case
Enter the P1 pressure value. Fully open the stop valve and press the SET button. P1 Press the SET button. P1 2. Enter the P2 pressure value.
] 0.03 0.02 0.02 P1=0.3 MPa P1=0.5 MPa P1=0.5 MPa P1=0.3 MPa P1=0.7 MPa P1=0.7 MPa 0.01 0.01 0 0 0 0 50 100 50 100 150 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM30-A AFD30-A P1=0.5 MPa 0.04 P1=0.7 MPa P1=0.3 MPa 0.04 P1=0.5 MPa P1=0.3 MPa 0.03 Pressure drop [MPa] Pressure drop [MPa] P1=0.7 MPa 0.03 0.02 0.02 P1=0.5 MPa P1=0.3 MPa P1=0.5 MPa P1=0.3 MPa 0.01 0.01 P1=0.7 MPa P1=
Clausings factor 8 Exhaust Time (Low/Medium Vacuum) K The time (t) required to exhaust a chamber at low vacuum with volume V (L), from pressure P1 to P2, using a pump with pumping speed S (L/sec) is t=2.3(V/S)log(P1/P2). In high vacuum, this is subject to the ultimate pressure limit imposed by outgassing and leakage as characterized above.