Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: G (Grommet w/0.3m Lead Wire), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure Supply, P Port: M (w/o Supply Adapter
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: Grommet w/0.3m Lead Wire, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port: w/o Supply Adapter, for Manifold, Vacuum
ISE When the values of P1 and P2 are the same or when P1>P2 within three digits, the hysteresis will be automatically three digits for the set value of P1. Window comparator mode: ZSE The hysteresis is two digits, so separate P1 from P2 by five digits or more and set them.
Z M1: Pitch moment Y X M2: Roll moment Static moment calculation by mounting type [Horizontal mounting] [Vertical mounting] [Ceiling mounting] [Wall mounting] M2 M1 A M2 M3 M3 M2 M1 A Y x y Z x z Y x y m x g X X Z y z m x g X M1 m x g Y m x g Table 2.
P A1 B1 1(P) port Pressure gauge option 4(A) port (P controlled type, A port regulation) M1 00 N0 No pressure gauge 2(B) port (P controlled type, B port regulation) Pressure gauge with MPa display Note 2) Pressure gauge with psi display Mounting screw Base gasket Connector gasket SY50M-M1(Without pressure gauge) SY50M-00/N0(With pressure gauge) SY70M-M1(Without pressure gauge) SY70M-00/N0
/D1/L1/M1 Series Battery-less Absolute (Step Motor 24 VDC) How to Order p. 172 Specifications p. 173 Dimensions p. 175 Options p. 177 Actuator Cable p. 178 JXC51/61/E1/91/P1/D1/L1/M1 Series Precautions Relating to Differences in Controller Versions p. 179 Specific Product Precautions p. 181 CE/UL-compliance List p. 182 10 11 Battery-less Absolute Encoder Type Slider Type Ball
3.2 4.2 13.4 M1 M2 L1 L2 M1 8 KQ2U08-10 18.5 45 13.7 21 25.6 17.7 18 10 KQ2U10-12 20.9 49 16.1 22 40 28.4 27 12 KQ2U12-16 26.5 66.5 23 25 57.4 45.4 100 Applicable tubing D2 Different Diameter Double Union Y: KQ2UD Applicable tubing O.D.
(Nm) ML2B/M1 (Pitch moment) ML2B/M2 (Roll moment) ML2B/M3 (Yaw moment) Pitch moment M1/M1e 10 20 40 Roll moment M2 1.2 2.4 4.8 Yaw moment M3/M3e 3.0 6.0 12 MI W S 40 Model 20 30 YES 20 5 4 3 10 ML2B25 ML2B32 ML2B40 CEP1 If speed or load changes, stopping time may vary and positioning accuracy may be compromised.
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 +0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P : Pressure drop (P1 P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures Multiply
(Copper-free) VH VHS IN P1 Flow Rate and Effective Area OUT IN P2 VR1211F Model Metric size 6 3.2 4 Applicable tubing O.D. If air is only supplied only to either P1 or P2 it, does not flow to the OUT side.
3.2 4.2 13.4 M1 M2 L1 L2 M1 8 KQ2U08-10 18.5 45 13.7 21 25.6 17.7 18 10 KQ2U10-12 20.9 49 16.1 22 40 28.4 27 12 KQ2U12-16 26.5 66.5 23 25 57.4 45.4 100 Applicable tubing D2 Different Diameter Double Union Y: KQ2UD Applicable tubing O.D.
(Copper-free) VH VHS IN P1 Flow Rate and Effective Area OUT IN P2 VR1211F Model Metric size 6 3.2 4 Applicable tubing O.D. If air is only supplied only to either P1 or P2 it, does not flow to the OUT side.
When P1 is blinking, use UP & DOWN key to reconfirm each and individual present value. When the input, value is blinking, press READ once to shift the operation back to P1. 48 11-2 Program Setting Input desired cylinder positions. 11-2-1 Input Method Turn the controller switching mode to PROGRAM. Note: Step 0 for every program is END. Program no 1 will start blinking.
M1 M1 D Pad side Pad side Pad side ZP2V-A01ZP2V-AN1ZP2V-A5ZP2V-A8ZP2V-AG1Vacuum generator side D Vacuum generator side M2 M2 L3 L2 H1 Vacuum generator side L2 L33 H1 M2 H1 (L4) (L4) No.0.8 No.0.8 (L4) No.0.8 H2 H2 L1 L1 L1 H2 M1 M1 M1 Pad side Pad side Pad side ZP2V-B01ZP2V-BN1ZP2V-BG1ZP2V-B5ZP2V-B61 The place at the vacuum generator side where the tool is applied. 2 The place at the pad
M1 M1 D Pad side Pad side Pad side ZP2V-A01ZP2V-AN1ZP2V-A5ZP2V-A8ZP2V-AG1Vacuum generator side D Vacuum generator side M2 M2 L3 L2 H1 Vacuum generator side L2 L33 H1 M2 H1 (L4) (L4) No.0.8 No.0.8 (L4) No.0.8 H2 H2 L1 L1 L1 H2 M1 M1 M1 Pad side Pad side Pad side ZP2V-B01ZP2V-BN1ZP2V-BG1ZP2V-B5ZP2V-B61 The place at the vacuum generator side where the tool is applied. 2 The place at the pad
UPDOWN PRG STEP P1 " 1000.0 " " " 1 READ " " P1 " UP DOWN P1 P2 P3 P4 P5 P6 P7 P8 48 11-2 11-2-1 PROGRAM STEP 0 End PRG 1 UPDOWN No.
ARBY3000-05--2 ARBY3000-06--2 ARBY3000-M1--2 ARBY5000-00--2 ARBY5000-M1--2 (For mounting odd number stations) (For mounting even number stations) + + + + + Note) ARBY is not CE-compliant.
(mm) a b (1) (1) Weight (g) D1 D2 L1 L2 P Q M1 M2 Part No.
P1+0.1 293 Q=600XC(P1+0.1) 273+t P2+0.1 If > b, a subsonic flow results. P1+0.1 P2+0.1 2 b P1+0.1 293 Q=600XC (P1+0.1) 1 1 b 273+t 103 Series SV EX500 Decentralized Serial Wiring Flow Characteristics of Solenoid Valve Q : Air flow rate [dm3/min(ANR)]. The dm3 (cubic decimeter) in the SI system may be expressed by L(liter). 1dm3=1L.