Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3A (Pressure Sensor, -100 to 100kPa, Accuracy ±1%
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: M (w/o Supply
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1A (Pressure Sensor, 0 to -101kPa, Accuracy ±1%
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2%
Main Body Shape: Unit, Additional Function: -, Ultimate Vacuum(kPa): -78, Air Consumption Flow Rate(l/min): 28, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C): 5:50~,
Main Body Shape: Unit, Additional Function: Filter, Ultimate Vacuum(kPa): -78, Air Consumption Flow Rate(l/min): 28, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C): 5
Main Body Shape: Unit, Additional Function: Filter, Ultimate Vacuum(kPa): -78, Air Consumption Flow Rate(l/min): 28, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C): 5
Main Body Shape: Unit, Additional Function: Filter, Ultimate Vacuum(kPa): -78, Air Consumption Flow Rate(l/min): 28, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C): 5
Main Body Shape: Unit, Additional Function: Filter, Ultimate Vacuum(kPa): -78, Air Consumption Flow Rate(l/min): 28, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C): 5
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±1% F.S., Air Pressure Supply
In the case of liquid: P Q = 1.9 x 106Av (9) G Q : Flow rate [l/min] Av : Flow coefficient [m2] P : Pressure difference [MPa] G : Relative density [water = 1] In the case of saturated aqueous vapor: Q = 8.3 x 106Av P(P2 + 0.1) (10) Q : Flow rate [m3/s] Av : Flow coefficient [m2] P : Pressure difference [Pa] P1 : Relative density [MPa]: P = P1 P2 P2 : Relative density [MPa] Front matter 4
Value is different from Kv and Cv factors for pneumatic purpose due to different test method. 3 3 Saturated steam flow rate Q0 [kg/h] (when Av = 1 x 106 [m2]) Water flow rate Q0 [L/min] (when Av = 1 x 106 [m2]) 2 Upstream pressure 2 P1 = 1 MPa P1 = 0.8 MPa 1 1 0.9 0.8 0.7 0.6 0.9 0.8 0.7 0.6 P1 = 0.6 MPa Example 2 P1 = 0.5 MPa P1 = 0.4 MPa 0.5 0.5 0.4 0.4 P1 = 0.3 MPa Example 1 0.3 0.3 P1
Tightening torque Caution M2: 0.16 Nm (SY3000) M3: 0.8 Nm (SY5000/7000) Manifold Parts No. Description Part no. SY3000 SY5000 Note No.
ISE When the values of P1 and P2 are the same or when P1>P2 within three digits, the hysteresis will be automatically three digits for the set value of P1. Window comparator mode: ZSE The hysteresis is two digits, so separate P1 from P2 by five digits or more and set them.
-9200-www.stevenengineering.com Approx. 600 140.2 P1 ZL Indicator light (Red) 31 51.4 Circuit diagram ZY EXH.
Values of pneumatic Kv are different from Cv because the testing method is different from each other. 3 3 Saturated aqueous vapor flow rate Q0 [kg/h] (when Av = 1 x 106 [m2]) Water flow rate Q0 [l /min] (When < when Av = 1 x 106 [m2]) 2 Upstream pressure P1 = 1MPa 2 P1 = 0.8MPa 1 0.9 0.8 0.7 0.6 0.5 1 0.9 0.8 0.7 0.6 0.5 P1 = 0.6MPa Ex. 2 P1 = 0.5MPa P1 = 0.4MPa 0.4 0.4 P1 = 0.3MPa Ex. 1
In the case of liquid: P Q = 1.9 x 106Av (9) G Q : Flow rate [l/min] Av : Flow coefficient [m2] P : Pressure difference [MPa] G : Relative density [water = 1] In the case of saturated aqueous vapor: Q = 8.3 x 106Av P(P2 + 0.1) (10) Q : Flow rate [m3/s] Av : Flow coefficient [m2] P : Pressure difference [Pa] P1 : Relative density [MPa]: P = P1 P2 P2 : Relative density [MPa] Front matter 4
P1+0.1 293 Q=600XC(P1+0.1) 273+t P2+0.1 If > b, a subsonic flow results. P1+0.1 P2+0.1 2 b P1+0.1 293 Q=600XC (P1+0.1) 1 1 b 273+t 103 Series SV EX500 Decentralized Serial Wiring Flow Characteristics of Solenoid Valve Q : Air flow rate [dm3/min(ANR)]. The dm3 (cubic decimeter) in the SI system may be expressed by L(liter). 1dm3=1L.