SMC Corporation of America
Elite Part Number Search
Search Results "ZM051AH-A5LZ-E14L-X111"

Nozzle Diameter: ø0.5, Body Style: 1 (Single Unit w/Valve + Standard Silencer), Vacuum Port Location: A (Side Entry), Standard Supply Pressure: H (0.5 MPa), Thread Type: Rc, Supply/Release Valve: A (Supply Valve), Solenoid Valve Rated Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override

Nozzle Diameter: ø0.5, Body Style: Single Unit w/Valve + Standard Silencer, Vacuum Port Location: Side Entry, Standard Supply Pressure: 0.5 MPa, Thread Type: Rc, Supply/Release Valve: Supply Valve, Solenoid Valve Rated Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Style

This is a legacy product, and replaced byZM101HT-K5L-E14L, VACUUM GENERATOR,HIGH PRESS/DC, VACUUM SERIES, ZM VACUUM SYSTEM, CD, ZM NOZZLE SIZE 1.0, .94600 lb, ModelStandard Supply PressureMax. Vacuum PressureMax. Suction FlowAir ConsumptionNZM10?H5Kgf/cm2 / 75PSI?630mmHg3646

Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E55 (1 Output w/o Analog Output, 200° Setting, PNP Output), Vacuum Switch Electrical Entry: C (Connector Lead Wire Length 0.6m), Release Flow Rate Adjusting Needle: L (With Lock Nut), Made to Order: X111

), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E14 (1 Output w/o Analog Output, 3 Rotation), Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Nozzle Diameter: ø1.0, Body Style: Single Unit w/Valve + Standard Silencer, Vacuum Port Location: Side/Bottom Entry, Standard Supply Pressure: 0.5 MPa, Thread Type: Rc, Supply/Release Valve: Supply Valve, Solenoid Valve Rated Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: Non-locking Push

Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E55 (1 Output w/o Analog Output, 200° Setting, PNP Output), Vacuum Switch Electrical Entry: C (Connector Lead Wire Length 0.6m), Release Flow Rate Adjusting Needle: L (With Lock Nut), Made to Order: X111

Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E55 (1 Output w/o Analog Output, 200° Setting, PNP Output), Vacuum Switch Electrical Entry: C (Connector Lead Wire Length 0.6m), Release Flow Rate Adjusting Needle: L (With Lock Nut), Made to Order: X111

, Solenoid Valve Rated Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: B (Locking Slotted Type), Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

, Solenoid Valve Rated Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Light/Surge Voltage Suppressor: Z (w/Light/Surge Voltage Suppressor), Manual Override: B (Locking Slotted Type), Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Valve: Without Valve, Solenoid Valve Rated Voltage: W/out Valve/Air Operated, Electrical Entry: W/out Valve/Air Operated, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style, Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire), Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style, Vacuum Switch Model: E55 (1 Output w/o Analog Output, 200° Setting, PNP Output), Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Supply/Release Valve), Solenoid Valve Rated Voltage: W/out Valve/Air Operated, Electrical Entry: W/out Valve/Air Operated, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style, Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

Valve: Without Valve, Solenoid Valve Rated Voltage: W/out Valve/Air Operated, Electrical Entry: W/out Valve/Air Operated, Light/Surge Voltage Suppressor: None, Manual Override: Non-locking Push Style, Vacuum Switch Model: Without switch, Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111

: 5 (24VDC), Electrical Entry: G (Grommet Type w/0.3m Lead Wire), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Manual Override: Non-locking Push Style, Vacuum Switch Model: E14 (1 Output w/o Analog Output, 3 Rotation), Vacuum Switch Electrical Entry: Grommet Type, Lead Wire (ZSE1: 0.6m, ZSM1: 0.5m), Release Flow Rate Adjusting Needle: Without Lock Nut, Made to Order: X111