Your search for ZSE20 returned 30 result(s)
There were no hits with the full part number, but there were 56 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
(F)-L/ISE20B-L Series How to Order p. 15 Specifications p. 16 Set Pressure Range and Rated Pressure Range p. 17 Analog Output p. 17 IO-Link: Process Data p. 17 Functions p. 17 Internal Circuits and Wiring Examples p. 19 Dimensions p. 20 Function Details p. 34 Made to Order p. 38 Safety Instructions Back cover 8 1 Output 3-Screen Display High-Precision Digital Pressure Switch RoHS ZSE20(F
-100.0100.0 kPa T 2 N NPN1 P PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L 2m -8No.PS-OMS0006CN-G / A ZS-46-A1 3X8L (2 ) B ZS-46-A2 3X8L (2 ) ZS-46-B + ZS-46-D ZS-46-3L 3 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch ZS-46-N7H 4mm ZS-46-C4L 6mm ZS-46-C6L 1/4 inch ZS-46-N7L -9No.PS-OMS0006CN-G LCD LCD
Suction Verification High Vacuum Suction Work 1 Work 2 Work n Max. A Formula for Obtaining the Set-Value P-1 P_1 or P_2 H_1 or H_2 H-1 P_1 (P_2) = A (A-B)/4 n_1 (n_2) = B + (A-B)/4 H_1 (H_2) = | (A-B)/2| n-1 Min.
(When replacing the piping adapter ZS-39-N, tighten it using the same method.) Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the Z/ISE20 body with a spanner.
1 Output RoHS 3-Screen Display High-Precision Digital Pressure Switch IP40 ZSE20(F)/ISE20 Series How to Order Rated pressure range ISE20 0.1 to 1 MPa M For positive pressure ISE20 M5 N For vacuum/ compound pressure ZSE20 N M M5 q w e r t y u q Rated pressure range e Unit specification w Output specification ZSE20 0 to 101 kPa ZSE20F 100 to 100 kPa Symbol Description N NPN open collector 1
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: Operation Manual, Calibration Certificate
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: Operation Manual, Calibration Certificate
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: ø1/4" One-touch Fitting, Straight Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: Operation Manual, Calibration Certificate
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N7H (ø1/4" One-touch Fitting, Straight Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: K (Operation Manual, Calibration Certificate)
Specifications Model ISE35 Rated pressure range 0 to 1 MPa Display/setting pressure range 0.1 to 1 MPa ZSE20 ISE20 Withstand pressure 1.5 MPa ZSE30 ISE30 Minimum display/setting unit 0.01 MPa Applicable fluid Air, Non-corrosive gas, Non-flammable gas ZSE40 ISE40 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Power supply voltage ZSE10 ISE10 Current consumption
ZP2-16UCL ZP (10, 13, 16) U ZP (10, 13, 16) C ZP (10, 13, 16) B ZP (10, 16) D ZPT2-A5, A6 ZPT2-B5, B6 B01, N01 T01 P. 72 P. 73 ZP (20, 25, 32) U ZP (20, 25, 32) C ZP (20, 25, 32) B ZP25D ZP2-B25J ZP2-B30J ZP2-25UCL ZP2-32UCL ZPT3-A6, A8 ZPT3-B5, B6, B8 B01, N01 T01 P. 72 P. 73 ZP (40, 50) U ZP (40, 50) C ZP (40, 50) B ZP40D ZPT4-A6, A8 ZPT4-B6, B8 B01, N01 T01 ZP2-40UCL ZP2-50UCL P. 72 P
K Hexagon width across flats 12 Hexagon width across flats 12 ZU ZL ZY ZQ ZF ZP ZCU AMJ Bellows Bellows A D E F N P A E F N P B B Y Y C C D Misc.
ZP2-16UCL ZP (10, 13, 16) U ZP (10, 13, 16) C ZP (10, 13, 16) B ZP (10, 16) D ZPT2-A5, A6 ZPT2-B5, B6 B01, N01 T01 P. 72 P. 73 ZP (20, 25, 32) U ZP (20, 25, 32) C ZP (20, 25, 32) B ZP25D ZP2-B25J ZP2-B30J ZP2-25UCL ZP2-32UCL ZPT3-A6, A8 ZPT3-B5, B6, B8 B01, N01 T01 P. 72 P. 73 ZP (40, 50) U ZP (40, 50) C ZP (40, 50) B ZP40D ZPT4-A6, A8 ZPT4-B6, B8 B01, N01 T01 ZP2-40UCL ZP2-50UCL P. 72 P