Your search for ZSE20 returned 30 result(s)
There were no hits with the full part number, but there were 56 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
p. 15 Air General fluids For vacuum pressure For compound pressure For positive pressure For vacuum pressure For compound pressure For positive pressure (1 MPa) For positive pressure (2 MPa) ZSE20B(-L) ZSE20BF(-L) ISE20B ZSE20C ZSE20CF ISE20C ISE20C IO-Link compatible/ L type 2 MPa 1 MPa 1 MPa 1 MPa IO-Link compatible/ L type 100 kPa 100 kPa 100 kPa IO-Link compatible/ L type 0 0 0 0 100
If the leakage volume is 30 L/min (ANR), the vacuum pressure of the S type is 20 kPa : l @ l ., and for the L type it is 33 kPa :' l @' l .'. If the leakage volume is 5 L/min (ANR), the vacuum pressure of the S type is 80 kPa ; l = l B, and for the L type it is 47 kPa ;' l =' l B'.
If the leakage volume is 30 L/min (ANR), the vacuum pressure of the S type is 20 kPa : l @ l ., and for the L type it is 33 kPa :' l @' l .'. If the leakage volume is 5 L/min (ANR), the vacuum pressure of the S type is 80 kPa ; l = l B, and for the L type it is 47 kPa ;' l =' l B'.
-N01-B12 ZPX100-T01-B12 ZPX125-B01-B10 ZPX125-N01-B10 ZPX125-T01-B10 ZPX125-B01-B12 ZPX125-N01-B12 ZPX125-T01-B12 ZPA-X1-B01-B8 ZPA-X1-N01-B8 ZPA-X1-T01-B8 ZPA-X1-B01-B10 ZPA-X1-N01-B10 ZPA-X1-T01-B10 ZPA-X1-B01-B8 ZPA-X1-N01-B8 ZPA-X1-T01-B8 ZPA-X1-B01-B10 ZPA-X1-N01-B10 ZPA-X1-T01-B10 ZPA-X2-B01-B10 ZPA-X2-N01-B10 ZPA-X2-T01-B10 ZPA-X2-B01-B12 ZPA-X2-N01-B12 ZPA-X2-T01-B12 ZPA-X2-B01-B10
Before Use Digital Pressure Switch ZSE20B(F)-L/ISE20B-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.
SUS304NBR POMSUS304NBRC3604 24 g 34 g 36 g 30 g 30 g +39 g 0.15 mm 2(AWG26) 1.0 mm (5 ) 3.5 -78No.PS-OMU0005CN-C M5 7 3.5 01/N01 A 01 R1/8 10 N01 NPT1/8 12 C4LC6L 4 A B C4L 17.5 8.2 C6L 18.3 10.4 -79No.PS-OMU0005CN-C A B -80No.PS-OMU0005CN-C 0.5~7 + 0.5~7 -81No.PS-OMU0005CN-C 2 (n ) <> <> 31n +3.5(n -1) 31n +3.5(n -1) -82No.PS-OMU0005CN-C Revision history A [2018 7 ] B [2020
Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: Operation
This is a legacy product, and replaced byZSE20B-Y-M-N01-WK, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, 0.32447 lb
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)