SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20BF-V-N01-WDK"

Load impedance Maximum load impedance at power supply voltage of 12 V: 300 at power supply voltage of 24 V: 600 Minimum load impedance: 50 Input type Non-voltage input: 0.4 V or less Input mode Select from Auto-shift or Auto-shift zero.

B -15No.PS-OMU0005CN-C (a)(a) (b) (ZS-46-B) +(ZS-46-D) 90 -16No.PS-OMU0005CN-C (-M5) 1/6~1/4 1~1.5Nm (ZS-46-N) -01-N01 23 3~5 Nm -C4L-C6L 1/61/4 1~1.5Nm -17No.PS-OMU0005CN-C -18No.PS-OMU0005CN-C () TU0425( 42.5) -19No.PS-OMU0005CN-C FG -20No.PS-OMU0005CN-C Z/ISE20B(F)-S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max.28 V80 mA 1 V -X () -S

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.

Units specification Pressure range Default setting ISE20B: 0.050 MPa/ZSE20B: 5.0 kPa/ ZSE20BF: 5.0 kPa Hysteresis ISE20B MPa "Nil" or M ZSE20B(F) kPa Delay time 0.00 sec.

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover), Operation

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover), Operation Manual: K (Operation Manual, Calibration Certificate)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover), Operation Manual: K (Operation Manual, Calibration Certificate)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover), Operation Manual: K (Operation Manual, Calibration Certificate)

-N01-B12 ZPX100-T01-B12 ZPX125-B01-B10 ZPX125-N01-B10 ZPX125-T01-B10 ZPX125-B01-B12 ZPX125-N01-B12 ZPX125-T01-B12 ZPA-X1-B01-B8 ZPA-X1-N01-B8 ZPA-X1-T01-B8 ZPA-X1-B01-B10 ZPA-X1-N01-B10 ZPA-X1-T01-B10 ZPA-X1-B01-B8 ZPA-X1-N01-B8 ZPA-X1-T01-B8 ZPA-X1-B01-B10 ZPA-X1-N01-B10 ZPA-X1-T01-B10 ZPA-X2-B01-B10 ZPA-X2-N01-B10 ZPA-X2-T01-B10 ZPA-X2-B01-B12 ZPA-X2-N01-B12 ZPA-X2-T01-B12 ZPA-X2-B01-B10

-N01-B12 ZPX100-T01-B12 ZPX125-B01-B10 ZPX125-N01-B10 ZPX125-T01-B10 ZPX125-B01-B12 ZPX125-N01-B12 ZPX125-T01-B12 ZPA-X1-B01-B8 ZPA-X1-N01-B8 ZPA-X1-T01-B8 ZPA-X1-B01-B10 ZPA-X1-N01-B10 ZPA-X1-T01-B10 ZPA-X1-B01-B8 ZPA-X1-N01-B8 ZPA-X1-T01-B8 ZPA-X1-B01-B10 ZPA-X1-N01-B10 ZPA-X1-T01-B10 ZPA-X2-B01-B10 ZPA-X2-N01-B10 ZPA-X2-T01-B10 ZPA-X2-B01-B12 ZPA-X2-N01-B12 ZPA-X2-T01-B12 ZPA-X2-B01-B10