There were no hits with the full part number, but there were 56 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
() Blue DC () When used as an IO-Link device Brown L + L + Black C/Q Main circuit C/Q IO-Link master Gray NC White NC Blue L L 19 3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20 Series Dimensions ZSE20(F) ISE20 ZSE20C(F)/ISE20C(H) ZSE20B(F)/ISE20B ZSE20B(F)-L/ISE20B-L ZSE20A(F)/ISE20A ZSE20(F)/ISE20 Function Details Made to Order Piping specification M5 For 20 25
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
ON-OFF () 1 L/min ,10 11 12 1 L/min SI SI ON-OFF ON 0 ripple -15No.PF-OMO0004CN-E AB.
ZSE20CF ISE20C ISE20CH () () () () 3 MPa,kPa,kgf/cm 2,bar,psi,InHg, mmHg MPa,kPa,kgf/cm 2,bar,psi LCD 3 (X2) 1)/ 2) 1)4 7 2)4 (1 11 7 ) ON OUT1OUT2 4 0,10,50,100,500,1000,5000 ms IP65 AC250 V 1 2 M(DC50 V ) -550 -1060 () 3585RH() UL/CSA(E216656)CE(EMC RoHS ) 2 m 1(0 ms) 2 3MPa/kPa 490% 5 02(L) N02(L) F02(L) C01(L) A2(L) B2(L) R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 SUS630SUS304
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Before Use Digital Pressure Switch ZSE20C(F)-L/ISE20C(H)-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.
Refer to L dimensions Enter a number from the DIN rail dimension table below. d L 8 (10) D (24) (35) 5.5 A L Rail mounting hole pitch: 12.5 0 98 24.8 5 160.5 40.6 7 185.5 46.9 1 110.5 28 6 173 43.8 8 198 50.1 2 123 31.1 9 210.5 53.3 3 135.5 34.3 4 148 37.4 No.
(For type 20 manifold) SYJ5 10 2 1 3 5 L M5 Body ported 10 SYJ5 4 2 5 3 L CE-compliant Base mounted Nil Q CE-compliant Note) AC-type models that are CE-compliant have DIN terminals only.