SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20C-V-N02L"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: w/o Lead Wire, Bracket: Bracket C, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 78 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 117 lb

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. VACUUM SWITCH, ZSE30, ZSE30A. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 117.00000 lb. N63.

Load impedance Maximum load impedance at power supply voltage of 12 V: 300 at power supply voltage of 24 V: 600 Minimum load impedance: 50 Input type Non-voltage input: 0.4 V or less Input mode Select from Auto-shift or Auto-shift zero.

DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -21No.PS-OMU0008CN-D ZSE20C(F)/ISE20C(H)-S/-R () NPN 2 DC(+) Max.28 V80 mA 1 V R15 V OUT1 1 k S420 mA OUT2 12 V 300 24 V 600 DC(-) 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -22No.PS-OMU0008CN-D -V/-T () PNP 2 DC(+) Max.80 mA 1 V T15 V OUT1 1 k V420 mA OUT2

1.5 V or less (Load current 80 mA) Delay time 1 1.5 ms or less, Variable at 0 to 60 s/0.01 s step Hysteresis Hysteresis mode Variable from 0 2 Window comparator mode Short circuit protection Provided -92No.PS-OMX0002-A ZSE20C ZSE20CF ISE20C ISE20CH Product No.

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.

) ZS-33-JS () ZS-33-M () (3.02 ) ZS-33-MS () (3.03 ) ZS-33-R DIN 1 2 3 4 5 DIN F02(G/14)DIN -12No.PF-OMO0004CN-E (OUT) (IN) 1 2 2 INOUT DIN 1 2: LCD LED (UP) (SET) SET (DOWN) UP DOWN 3 ON/OFF (UP) 3 ON/OFF (DOWN) LED (OUT1)/ (SET) OUT1OUT2 OUT1ON OUT2ON 3 -13No.PF-OMO0004CN-E F.S. () 15 V F.S.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] 15 V 15 V 420 mA ON OFF ()

Bracket C MPa ISE20C(H) ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa "Nil" or M Hysteresis Self tapping screws: Nominal size 3 x 8L kPa ZSE20C(F) Self tapping screws: Nominal size 3 x 10L Safety Instructions Bracket A ISE20C(H) Delay time 1.5 ms or less psi P ZSE20C(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended