ISE20C ISE20CH () () () () 3 MPa,kPa,kgf/cm 2,bar,psi,InHg, mmHg MPa,kPa,kgf/cm 2,bar,psi LCD 3 (X2) 1)/ 2) 1)4 7 2)4 (1 11 7 ) ON OUT1OUT2 4 0,10,50,100,500,1000,5000 ms IP65 AC250 V 1 2 M(DC50 V ) -550 -1060 () 3585RH() UL/CSA(E216656)CE(EMC RoHS ) 2 m 1(0 ms) 2 3MPa/kPa 490% 5 02(L) N02(L) F02(L) C01(L) A2(L) B2(L) R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 SUS630SUS304 ()

p. 15 Air General fluids For vacuum pressure For compound pressure For positive pressure For vacuum pressure For compound pressure For positive pressure (1 MPa) For positive pressure (2 MPa) ZSE20B(-L) ZSE20BF(-L) ISE20B ZSE20C ZSE20CF ISE20C ISE20C IO-Link compatible/ L type 2 MPa 1 MPa 1 MPa 1 MPa IO-Link compatible/ L type 100 kPa 100 kPa 100 kPa IO-Link compatible/ L type 0 0 0 0 100

Option -L Port combination: Individual PV Common PS = Common PD Port layout No. 19 Circuit example Single unit: ZK2HlR KlllA-l-L Manifold: ZZK2lA-A2l-L PV PV EXH EXH Common PS Common PS Common PD Common PS Common PV Common PS Common PV Common PD (= Common PD) (= Common PD) Individual PV Individual EXH (including PE) High-noise reduction High-noise reduction silencer exhaust silencer exhaust

Before Use Digital Pressure Switch ZSE20C(F)-L/ISE20C(H)-L Mounting and Installation Outline of Settings [Measurement mode] Function Selection Mode Installation Mounting Mount the optional bracket and panel mount adapter to the pressure switch.

VCRSwagelok Company -6No.PS-OMM0002CN-F * 6 33 () () 10m DC(-)() * ( ) () CE -7No.PS-OMM0002CN-F 0~50(5) SUS630() SUS304() ( ) * 10~15 15 /1% 1941 LCD * -8No.PS-OMM0002CN-F ISE80 02 N 3 ISE80 -0.11MPa ZSE80 0-101KPa ZSE80F -100100KPa ISE80H -0.12MPa Y K + T + 2 02 R1/4 N02 NPT1/4 F02* G1/4 G01 Rc1/8 A2 URJ1/4 B2 TSJ1/4 A (ZS-24-A/ZS-35-A) B *(ZS-24-D) C D + F02 ISO228-1 1 *1 L

min 550 L/min 10100 L/min 20200 L/min 50500 L/min / 12 0.510.5 L/min 2.552.5 L/min 5105 L/min 10210 L/min 25525 L/min / 0.1 L/min 0.5 L/min 1.0 L/min 2.0 L/min 5.0 L/min / 09 L / 1 L 3 4 -50 kPa0.5 MPa -50 kPa0.75 MPa 1.0 MPa NPN PNP 3 () 3 80 mA DC30 V(NPN ) NPN1 V (80 mA ) PNP1.5 V (80 mA ) 1 s 1F.S. 2F.S. 5F.S. 0 3 (3 digits) 50 ms 0.1 L/pulse 0.5 L/pulse 1 L/pulse 2

M45 L 2 ZS-24-B B M45 L, 2 ZS-24-D D M35 L,M45 L 2 ZS-35-C (01,N01) ZS-35-D (W1,WF1,M5,C4,C6) ZS-35-F +(01,N01) ZS-35-G +(W1,WF1,M5,C4,C6) -10No.PS-OMM0006CN-E M8(3 ) 01 N M L ISE40A 1/ 2 ISE40A -0.11.000 MPa Y ZSE40A 0.0-101.3 kPa K + T + 1 01 R1/8(M5) N01 NPT1/8(M5) A A D D N NPN1 M8 P PNP1 /M8 1 L M SI2 M8 P (psi)1 1 2kPaMPa 1 ZS-24-A A M35 L,M45 L, 2 ZS-24-D D M35

2 ) A(ZS-38-A1) M35 L B(ZS-38-A2) A M35 L M35 L B M35 L -14No.PS-OML0002CN-G C(ZS-38-A3) M35 L C M35 L A/B/C4 -15No.PS-OML0002CN-G M38 L(2) (ZS-27-C) +(ZS-27-D) M3X8L ( ) (ZS-27-C/D) 90 2 -16No.PS-OML0002CN-G 1. 2. 1)0.1 mm 2)0.1 mm 3)+0.15 mm -0.2 mm -17No.PS-OML0002CN-G ,FG () () DC(+) 5 OUT1 4 OUT2 3 (FUNC) 2 DC(-) 1 -18No.PS-OML0002CN-G Z/ISE30A(F)--DC(+) OUT -N NPN 1 Max

OFF Hysteresis ON-OFF / "()" () () 25[]ON-OFF -10No.PS-OMH0005CN-D NPN () () ON ON 0 PSE530 ( ) 20 () ON-OFF "digit" () 0 () SI ONOFF () 1 (=CH2CH3CH4)2 (=CH1)2 () 2 CH1CH4 ON -11No.PS-OMH0005CN-D ON () (n1L~n1H n2L~n2H) ON (20 ) Hysteresis "" 20 ON () (P1LP1H P2LP2H) ON (20 ) () 5%R.D.(5%) (0~1MPa 0.001MPa 1/1000) "()" () "" () ripple -12No.PS-OMH0005CN-D M38 L(

After [A2L] is displayed and measurement starts, when the pressure change is detected, a set value will appear automatically. (When OUT2 setting is not necessary, press the and buttons simultaneously for 1 second or more to return to measurement mode). Initial Setting Troubleshooting Warning Auto-preset is being set Error Indication Initial setting is required for each channel.

Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMS0006CN-G * FG (35 N () ,() *() 6 33 () () 30m DC(-)() * -6No.PS-OMS0006CN-G ( ) () CE/UKCA -5~50(5 ) * , 1015 10 1% 2053 LCD * -7No.PS-OMS0006CN-G N M5 ISE20 3 ISE20 -0.1001.000 MPa Y ZSE20 0.0-101.0 kPa K ZSE20F -100.0100.0 kPa T 2 N NPN1 P PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L

Current pressure value (Main display) Output mode Hysteresis mode Item (Sub display (left)) Set value or peak/bottom value (Sub display (right)) Reversed output Normal output [F 0] Units selection function ISE20C: 0.500 MPa/ZSE20C: -50.5 kPa/ ZSE20CF: 50.0 kPa/ISE20CH: 1.000 MPa Default setting Units specification Pressure range Pressure setting Sub display In measurement mode, the display

ZSE20C is vacuum rated, while the ZSE20CF is rated for both vacuum and a low positive pressure range.  Each model in the ZSE20 family offers a 3-screen, 3-color display.  The main screen shows the curent measured value in red or green, while two sub-screens can display the setting label and its numeric value in orange. 

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -