The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 117 lb

e r t y u i o q Rated pressure range w Output specification u Option 2 * Note that the optional parts that can be used vary depending on the piping direction.

DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -21No.PS-OMU0008CN-D ZSE20C(F)/ISE20C(H)-S/-R () NPN 2 DC(+) Max.28 V80 mA 1 V R15 V OUT1 1 k S420 mA OUT2 12 V 300 24 V 600 DC(-) 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -22No.PS-OMU0008CN-D -V/-T () PNP 2 DC(+) Max.80 mA 1 V T15 V OUT1 1 k V420 mA OUT2

N (2 m) (2 m) + () 2 R S () () T V () () -11No.PF-OMO0004CN-E / ZS-33-D 2m ZS-33-F ZS-33-J () ZS-33-JS () ZS-33-M () (3.02 ) ZS-33-MS () (3.03 ) ZS-33-R DIN 1 2 3 4 5 DIN F02(G/14)DIN -12No.PF-OMO0004CN-E (OUT) (IN) 1 2 2 INOUT DIN 1 2: LCD LED (UP) (SET) SET (DOWN) UP DOWN 3 ON/OFF (UP) 3 ON/OFF (DOWN) LED (OUT1)/ (SET) OUT1OUT2 OUT1ON OUT2ON

-7No.PS-OMM0002CN-F 0~50(5) SUS630() SUS304() ( ) * 10~15 15 /1% 1941 LCD * -8No.PS-OMM0002CN-F ISE80 02 N 3 ISE80 -0.11MPa ZSE80 0-101KPa ZSE80F -100100KPa ISE80H -0.12MPa Y K + T + 2 02 R1/4 N02 NPT1/4 F02* G1/4 G01 Rc1/8 A2 URJ1/4 B2 TSJ1/4 A (ZS-24-A/ZS-35-A) B *(ZS-24-D) C D + F02 ISO228-1 1 *1 L M SI*2 P (psi)*1 1 2 ISE80H: MPa MPa kpa N NPN1 P PNP1 A NPN2 B PNP2 R

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

This is a legacy product, and replaced byISE20C-X-N02L-W, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DB, ISE40/50/60 1/4 NPT VERSION, .44092 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay

Current pressure value (Main display) Output mode Hysteresis mode Item (Sub display (left)) Set value or peak/bottom value (Sub display (right)) Reversed output Normal output [F 0] Units selection function ISE20C: 0.500 MPa/ZSE20C: -50.5 kPa/ ZSE20CF: 50.0 kPa/ISE20CH: 1.000 MPa Default setting Units specification Pressure range Pressure setting Sub display In measurement mode, the display

Bracket C Units specification Pressure range Default setting ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa Hysteresis ISE20C(H) MPa Self tapping screws: Nominal size 3 x 8L "Nil" or M Self tapping screws: Nominal size 3 x 10L ZSE20C(F) kPa Delay time 0.00 sec.

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation