e r t y u i o q Rated pressure range w Output specification u Option 2 * Note that the optional parts that can be used vary depending on the piping direction.
ZSE20C 0.0~-101.0 kPa K ZSE20CF -100.0~100.0 kPa T ISE20CH -0.100~2.000 MPa 24 X NPN2 A1 A Y PNP2 A3 C R NPN2+1 B T PNP2+1 E S NPN2+1 D + V PNP2+1 1: F + 4 2 M SI3 1 P psi2 2 3 kPaMpa (2m ) W 2 R1/4 C01 Rc1/8 N02 NPT1/4 A2 URJ1/4 L F02 G1/4 B2 TSJ1/4 2 2 () L() A A1 ZS-46-A1 C A3 ZS-46-E B ZS-46-B E ZS-35-B D ZS-46-D + F ZS-35-E -9No.PS-OMU0008CN-D / A ZS-46-A1
w AC-A w t y AC-B t q q q IN OUT IN OUT IN OUT r y y e u e r t u r i u Drain Drain Drain Component Parts No.
40 Pilot EXH 177.5 14 (3(R) port) 2 x 5.5 Mounting hole 2 x 1/4 (: Thread type) 1 3 Manual override 23 9 19 3(R) port 1(P) port Conduit terminal VFN212N-lTll-02l-l-l Grommet VFN212N-lGll-02l-l-l Surge voltage suppressor (With "S") 137 41.7 300 19 23 Indicator light (With "Z") 74(Without "Z": 64) 64(Without "Z": 54) Grommet terminal VFN212N-lEll-02l-l-l Lead wire O.D. 3.5 at max.
seal Mini Y seal Pilot valve assembly Double check spacer AXT510-13 VQ7060-13-2 VQ7080-13-1 VQ7080-13-3 37 x 1.6 NBR NBR NBR NBR NBR NBR NBR MYN-8 MYN-16 MYN-14 VQZ110QVV72-FPG 21 Series VQ7-8 Manifold Series VV72 How to Order Manifolds VV72 6 04D 03R Stations Air release valve coil rating 1 station 1 None 100VAC 50Hz/60Hz 200VAC 50Hz/60Hz 24VDC 12VDC Other ... ...
y e q w y e q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VQ7-6-FG-DVQ7-6-FG-D-R o o t r u t r u w y e q w y e q FHG FJG FIG FHG FJG FIG VQ7-6-DVQ7-6-D-R o o t r u t r u w y e q w y e q VQ7-6-FPG-Do t r u w y e q i Replacement Parts (For valve) FHG FJG FIG FHG
y e q w y e q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VQ7-6-FG-DVQ7-6-FG-D-R o o t r u t r u w y e q w y e q FHG FJG FIG FHG FJG FIG VQ7-6-DVQ7-6-D-R o o t r u t r u w y e q w y e q VQ7-6-FPG-Do t r u w y e q i Replacement Parts (For valve) FHG FJG FIG FHG
Low power consumption 1.8 W DC Available in 2 or 3 position, single or double solenoid pilot configuration. Long service life Rubber seal: 30 million cycles or more Metal seal: 50 million cycles or more Subject to SMCs own test data using clean and dry air.
e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR30l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR30l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 800 Precision Regulator IR1000-A/2000-A/3000-A Series Dimensions Basic type (Knob): IR10l0-01l-A 10.5 42 ARJ 1.6 Bracket AR425 to 935 Mounting hole for hexagon
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
This is a legacy product, and replaced byISE20C-Y-M-02L-W, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .50472 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20C-Y-02L-W, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .22639 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)