SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20CF-Y-A2L"

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 120 lb

ZSE20C 0 to 101 kPa ZSE20CF 100 to 100 kPa Symbol Description R NPN open collector 2 outputs + Analog voltage output*1 S NPN open collector 2 outputs + Analog current output*1 T PNP open collector 2 outputs + Analog voltage output*1 V PNP open collector 2 outputs + Analog current output*1 X NPN open collector 2 outputs + Copy function Y PNP open collector 2 outputs + Copy function Symbol

ZSE20C 0.0~-101.0 kPa K ZSE20CF -100.0~100.0 kPa T ISE20CH -0.100~2.000 MPa 24 X NPN2 A1 A Y PNP2 A3 C R NPN2+1 B T PNP2+1 E S NPN2+1 D + V PNP2+1 1: F + 4 2 M SI3 1 P psi2 2 3 kPaMpa (2m ) W 2 R1/4 C01 Rc1/8 N02 NPT1/4 A2 URJ1/4 L F02 G1/4 B2 TSJ1/4 2 2 () L() A A1 ZS-46-A1 C A3 ZS-46-E B ZS-46-B E ZS-35-B D ZS-46-D + F ZS-35-E -9No.PS-OMU0008CN-D / A ZS-46-A1

Selectable option for manifold (Refer to i on pages 11 and 12, and y on page 13.)

-5No.PS-OMM0002CN-F SUS630SUS304 () * (14 ) FG (49 N () () TSJSwagelok(Swagelok URJ Swagelok(VCR)/GroundGround Swagelok,VCRSwagelok Company -6No.PS-OMM0002CN-F * 6 33 () () 10m DC(-)() * ( ) () CE -7No.PS-OMM0002CN-F 0~50(5) SUS630() SUS304() ( ) * 10~15 15 /1% 1941 LCD * -8No.PS-OMM0002CN-F ISE80 02 N 3 ISE80 -0.11MPa ZSE80 0-101KPa ZSE80F -100100KPa ISE80H -0.12MPa Y

() M8(3 ) * 6 33 () () 10m DC(-)() ( ) -6No.PS-OMM0006CN-E * ( ) () CE CE -550 (5 ) * ON , 1015 10 /1 2351 LCD -7No.PS-OMM0006CN-E * -8No.PS-OMM0006CN-E (M8(3 )11 ) 01 X M ISE40A 2 K ISE40A -0.11.000 MPa ZSE40A 0.0-101.3 kPa ZSE40AF -100.0100 kPa 1 01 R1/8 (M5) A A N01 NPT1/8 (M5) W1 Rc1/8 B B WF1 G1/81 D D M5 M5X0.8 () E C4 4 C6 6 F + 1IS0228-1 P10/1 X NPN2() Y

-2No.PS-OMS0006CN-G / *3) 1 1.5 3) 1 1 -3No.PS-OMS0006CN-G () () () () -4No.PS-OMS0006CN-G () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMS0006CN-G * FG (35 N () ,() *() 6 33 () () 30m DC(-)() * -6No.PS-OMS0006CN-G ( ) () CE/UKCA -5~50(5 ) * , 1015 10 1% 2053 LCD * -7No.PS-OMS0006CN-G N M5 ISE20 3 ISE20 -0.1001.000 MPa Y ZSE20 0.0-101.0 kPa K ZSE20F

1.5 3) 3) 1 1 () [] -3No.PS-OML0002CN-G () () () () -4No.PS-OML0002CN-G () * UL UL1310 2 UL1585 2 30[Vrms] 42.4[V ]2 UL (100 10 ) JIS B 8392-1 11.1.21.6.2:2003 () -5No.PS-OML0002CN-G * / / ,FG (35N ) () () * () 6 33 () () 10 m DC(-)() () * -6No.PS-OML0002CN-G ( ) () CE 050(5), * ON , 1015 10 /1 2146 LCD * -7No.PS-OML0002CN-G 01 N ISE30A 3 ISE30A -0.11 MPa Y

Current pressure value (Main display) Output mode Hysteresis mode Item (Sub display (left)) Set value or peak/bottom value (Sub display (right)) Reversed output Normal output [F 0] Units selection function ISE20C: 0.500 MPa/ZSE20C: -50.5 kPa/ ZSE20CF: 50.0 kPa/ISE20CH: 1.000 MPa Default setting Units specification Pressure range Pressure setting Sub display In measurement mode, the display

Bracket C Units specification Pressure range Default setting ISE20C: 0.050 MPa/ZSE20C: 5.1 kPa/ ZSE20CF: 5.0 kPa/ISE20CH: 0.100 MPa Hysteresis ISE20C(H) MPa Self tapping screws: Nominal size 3 x 8L "Nil" or M Self tapping screws: Nominal size 3 x 10L ZSE20C(F) kPa Delay time 0.00 sec.

ZSE20C is vacuum rated, while the ZSE20CF is rated for both vacuum and a low positive pressure range.  Each model in the ZSE20 family offers a 3-screen, 3-color display.  The main screen shows the curent measured value in red or green, while two sub-screens can display the setting label and its numeric value in orange. 

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported)