) P T 0.079 in (2mm) o.T. 0 059 in (1 smm) T T 0 138 in (3 Smm) .75 PSIG (5 Kgf/cm2) F .
) P T 0.079 in (2mm) o.T. 0 059 in (1 smm) T T 0 138 in (3 Smm) .75 PSIG (5 Kgf/cm2) F .
7 20 20 L (mm) Model G M W H S Z J V K L MXP16-20 18 40 65 58 20 102 93 82 40 36 MXP16-30 28 56 75 70 30 128 119 108 50 42 8-8-20 20 Precision Air Slide Table Series MXP Dimensions: MXP16 with Shock Absorber 2-M5 x 0.8, depth 8 Z 3 V K 6.5 MX Max. 15 11 M MTS Stroke: S MY MXP16-20B CY Width across flats 12 A MG M8 x 1 H Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco
SET-ON 10 Start readiness signal CN2 24V DC + COM 1 COM 11 NO. 0 Indicates operation in progress when ON. ON when program is being executed and when returning to the home position. 2 BUSY 11 Operating signal NO. 1 12 NO. 2 3 <1> When this signal is OFF, an alarm is being generated for the actuator/controller.
LD LH LS LT LX LZ MM N NA NB NC 20 to 800 18 13 26 10 16 12 8 41 5 8 30 5 7 25 121 5.5 40 55 M8 x 1.25 13 26 19 15 15.5 25 to 800 22 17 32 12 16 12 8 46 6 8 32 5.5 7 28 121 5.5 40 55 M10 x 1.25 13 28 19 15 19.5 32 to 800 24 22 38 16 19 12 8 53 8 9 40 7.5 7 30 133 6 45 60 M14 x 1.5 13 36 19 15 21 40 to 800 24 24 41 18 21 14 11 54 10 11 48 7.5 9 35 158 6 55 75 M16 x 1.5 19 44 24 21 21 (mm)
Changeable range output 5 V (10 V) 20 mA At the time of shipment 1 V (0 V) 4 mA Grease-free 10% 100% 105% Display 0% Application example Analog Functions Adjustment point: 75 L/min , 100 L/min output pp. 27, 28 When 5 V output is required from the flow switch at 75 L/min, use a sensor that outputs 1 to 5 V at 1 to 100 L/min. 5 V Change Output operation Key-lock function Forced output function
Bushing CDQ2B only A set of Nos.11, 12 and 13 from the table above 180 9 CQ2WB180-PS Magnet Nickel plated 200 10 Rolled steel CQ2WB200-PS Rod end nut Mounting 1in = 25.4mm Mounting/Through hole type mounting bolts are available. How to order: Add "Bolt" in front of the bolts to be used.
11 Series ZX Suction Filter Unit: ZX1-F Specifications ZX1-F Vacuum to 0.5 MPa 5 to 50C 30 m PVF 35 g Unit no.
Servo amp lifier Driver (Note 7) (Note 7) CN1 CN1 (Note 2) 24VDC RA1 (Note 4, 9) 2 OPC 9 ALM Trouble (Note 6) 1 DICOM Travel completion 10 MEND RA2 13 DOCOM (Note 9, 11) (Note 13) Ready EM1 SON MD0 8 4 3 (Note 3, 5) Forced stop 11 RD RA3 Servo-on Electromagnetic brake interlock 12 MBR RA4 Automatic/manual selection DOG (Note 9, 10, 12) 25 Proximity dog 10m max. Point table No.
Bore size Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches Lead wire length (m) Load voltage Auto switch model no.
, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125
3 3.125 1/2 1 1/2 3 1/2 7 5/8 4 5/8 11 3/8 12 3 2 1/4-12 3 1/2 3.75 1/2 1 1/2 3 1/2 7 5/8 4 5/8 11 3/8 14 2 1/2 1 7/8-12 3 3.125 1/2 1 1/2 3 13/16 8 7/8 5 1/2 12 7/8 14 3 2 1/4-12 3 1/2 3.75 1/2 1 1/2 3 13/16 8 7/8 5 1/2 12 7/8 14 3 1/2 2 1/2-12 3 1/2 4.25 1/2 1 1/2 3 13/16 8 7/8 5 1/2 12 7/8 F G J K L MR 3/4 2 1 1/2 9/16 1 1/2 1 3/16 3/4 2 1/4 2 11/16 2 1/8 1 5/8 3/4 2 1/4 2 11/16 2 1/4
7/8-12 3 3.125 1/2 1 1/2 3 1/2 7 5/8 4 5/8 11 3/8 12 3 2 1/4-12 3 1/2 3.75 1/2 1 1/2 3 1/2 7 5/8 4 5/8 11 3/8 14 2 1/2 1 7/8-12 3 3.125 1/2 1 1/2 3 13/16 8 7/8 5 1/2 12 7/8 14 3 2 1/4-12 3 1/2 3.75 1/2 1 1/2 3 13/16 8 7/8 5 1/2 12 7/8 14 3 1/2 2 1/2-12 3 1/2 4.25 1/2 1 1/2 3 13/16 8 7/8 5 1/2 12 7/8 F G J K L MR 3/4 2 1 1/2 9/16 1 1/2 1 3/16 3/4 2 1/4 2 11/16 2 1/8 1 5/8 3/4 2 1/4 2 11/16
(Tightening torque: 0.15 Nm) 11) For products with a switch, mount the switch assembly. (Be careful not to drop the O-ring.
241 181 377 283 0.7 35 26 79 59 141 105 220 165 343 251 563 422 879 659 0.6 30 22 68 50 121 90 188 141 294 215 482 362 754 565 0.5 25 19 57 42 101 75 157 118 245 179 402 302 628 471 8 5, 10, 15, 20, 25, 30 OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN 50 37 113 84 201 150 314 235 490 358 804 603 1,256 942 8 12, 16 25, 50, 75, 100 25, 50, 75, 100, 125, 150, 175, 200 12 20, 25, 32, 40 16
12 13 7 8 9 10 11 7 8 9 10 1112 13 14 15 Distance from cylinder shaft center L0 (cm) Distance from cylinder shaft center L0 (cm) Distance from cylinder shaft center L0 (cm) 100 REBR32 REBR25 10 REBR15 1 0.1 100 200 300 400 600 500 Maximum speed U (mm/s) 62 Series REBR Model Selection 3 Design Parameters 2 Maximum Load Weight when Loaded Directly
IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Series ZFB Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Metric size 3/16" 20 22 20 22 30 30 75 40 100 62 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 1/4" 1/4" Inch size (2) 3/8" 1/2" Specifications Fluid Air/Nitrogen Negative pressure 0.5MPa 0 to 60C (Non-freezing) 30m 0.15MPa Nylon/Soft Nylon/Polyurethane
Pin description 1 DC (+) 2 Analog output Accumulated pulse output wiring examples 3 DC () 4 OUT1 4-I thread with depth J 40 Max. 30V 80 mA or less OUT1 Black Load H 0V Blue 50 msec PF2A7H--28 29(-M) A B C D E F G H I J Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc 1, NPT 1, G 1 36 M5 x 0.8 8 OUT1 80 mA Load Black 65 180 45 104 79 65 Rc 11/2, NPT 11/2, G 11/2 Rc 2, NPT 2, G
11 10 Since this is a guideline including hysteresis, not meant to be guaranteed.
Refer to p.4.0-11 "Applicable Fluid Check List".