SMC Corporation of America
Elite Part Number Search
Search Results "55-JSXFAE-06N-B"

L E T U B E OD 6 A P P L I C A B L E T U B E OD 6 Courtesy of Steven Engineering, Inc. !

SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.

Proper Auto Switch Mounting Position D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BAL D-F7BAVL/F79F Auto switch model D-A79W D-F7NTL D-A7 D-A80 D-M9 D-M9V D-F9W D-F9WV D-A9 D-A9V D-F9BAL Bore size (mm) A B A B A B A B A B A B A B 12 40.5 4 41 4.5 38 2 46 9.5 39.5 3 43.5 7 42.5 6 20 47 13 47.5 13.5 44.5 10.5 52.5 18.5 46 12 50 16 49 15 32 55 17 5.5 17.5 52.5 14.5 60.5 22.5

A B A B A B A B A B A B 12 40.5 4 41 4.5 38 2 46 9.5 39.5 3 43.5 7 42.5 6 20 47 13 47.5 13.5 44.5 10.5 52.5 18.5 46 12 50 16 49 15 32 55 17 5.5 17.5 52.5 14.5 60.5 22.5 54 16 58 20 57 19 40 79 39 79.5 39.5 76.5 36.5 84.5 44.5 78 38 82 42 81 41 50 82 44 82.5 44.5 79.5 41.5 87.5 49.5 81 43 85 47 84 46 63 85.5 41.5 86 42 83 39 91 47 84.5 40.5 88.5 44.5 87.5 43.5 Operating Range Auto switch model

High Suction Vacuum Work 1 Work 2 Work n Max.A ON point OFF point Min.B Not adsorption Work 1 Work 2 Work n Atmosphere A B 4 A B 4 = A ON point Max.A: Maximum pressure value when workpiece is vacuumed. Min.B: Maximum pressure value when workpiece is not vacuumed.

A 35.5 44.5 52.5 76.5 79.5 83 A 37 46 54 78 81 84.5 B 5.5 12 16 38 43 40.5 A 41 50 58 82 85 88.5 B 9.5 16 20 42 47 44.5 A 38 47 55 79 82 85.5 B 6.5 13 17 39 44 41.5 B 7 13.5 17.5 39.5 44.5 42 A 43.5 52.5 60.5 84.5 87.5 91 B 12 18.5 22.5 44.5 49.5 47 B 4.5 10.5 14.5 36.5 41.5 39 CE1 CE1 12 20 32 40 50 63 CE2 ML2B Note) Adjust the auto switch after confirming the operating conditions in the

CRQ2X MSQX MRQ Auto Switch Working Principle [Pressure is applied from the B port.] The auto switch B is turned ON by the magnet B in the state that the pressure is applied from the B port and the piston B moves to the left side. At this time, the auto switch A turns OFF . Magnet B Piston B A port B port Auto switch B Auto switch A [Pressure is applied from the A port.]

J M N 10-/21-AR20-B 10-/21-AR25-B 10-/21-AR30-B 10-/21-AR40-B 10-/21-AR40-06-B 10-/21-AR50-B 10-/21-AR60-B 2 Note 2) 1/8, 1/4 28.5 1/8 20.5 40 11 67.4 44 26.5 65.5 M28 x 1 30 28.5 34 43.9 5.4 15.4 55 2.3 24.7 28.5 14 6 1/4, 3/8 0 27.5 1/8 21.3 53 9.8 71.9 44 28 64.5 M32 x 1.5 30 27.5 34 43.9 5.4 15.4 55 2.3 25.7 32.5 16 6 1/4, 3/8 3.5 29.4 1/8 24.8 53 10.5 85.6 44 30.7 66.4 M38 x 1.5 41

center 3 position exhaust center 3 position closed center 3 position pressure center (1) 3 position exhaust center 3 position closed center (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) Note 1) Except VQZ1000 and metal seal.

20 0.19 b 0.3 37 30 0.39 b 0.48 19 40 0.79 b 0.8 1.3 1 Compared with existing products (AFFmC, AMmC, and AMDmC series) 2 Compared with existing products (AMFmC series) 50 1.25 b 1.3 4 60 1.50 b 2.0 25 Color-identifiable elements This eliminates the accumulation of condensate.

43 10 31 19 15 36.5 24.5 D-A90V 5 25.5 26.5 13.5 14.5 A B A B A B A B C D Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.

Related Products DDimensions B + Stroke A + Stroke (mm) A 55 to 100 mm strokes B 55 to 100 mm strokes Bore size (mm) 32 40 50 63 80 100 65 67 76 80 89 95 73.5 75.5 87 91 100 107 Dimensions other than the above are the same as the standard double acting single rod type.

Flat Finger Type [3] 4-MM thread depth L Attachment mounting thread K J A A D G B D B K J F C S W O Unit: mm Weight g F G Open Closed 2 2.5 3 4 J K MM L B C D Model A W 5.4 7.4 4.45 5.8 7.45 8.9 M2.5 x 0.45 M3 x 0.5 M4 x 0.7 M5 x 0.8 5 6 8 10 55 115 235 420 5.2 8.3 10.5 13.1 10.9 14.1 17.9 21.8 2.45 3.05 3.95 4.9 6 8 10 12 5 8 10 12 +2.2 0 2H9 2.5H9 3H9 4H9 1.4 1.4 1.6 2 0 -0.2 0 -0.2 0 -

Applicable cylinder MY3A16, MY3B16 MY3A25, MY3B25 MY3A40, MY3B40 MY3A63, MY3B63 A B A B A B A B MY-S16 MY-S25 MY-S32 MY-S40 63.6 Data 091 130 182 Guide for Using Side Support For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight.

U A B B A D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U SMC SMC Approx. U B A B A Approx. U D-A73C D-A80C D-J79C D-A7*C,D-A80C Approx. U Approx. U D-A7*C,D-A80C A B A B Approx.

View B-B 50 HRZ HRZD Accessory: Y-strainer mounting view HRW * Mount it by yourself on the circulating fluid return port.

C D Side support B MY-SB 2 x J A B C D A 61 70 87 B 75 84 105 C D E F G H J Part no.

dimension) 20.4 [518] 1.97 [50] 24.3 [617] View A-A View B-B 1.97 [50] Accessory: Y-strainer mounting view Mount it by yourself on the circulating uid return port.

B Contact output signal 3 selected alarm Sets the alarm selected for the contact output signal 3. ---(AL.01)6 1: Default when CO02 is set to PRO1 or PRO2. 4: Default when CO23 is set to A.SEL. 2: Default when CO15 is set to SW-A or SW-B. 5: Default when CO26 is set to A.SEL. 3: Default when CO19 is set to SW-A or SW-B. 6: Default when CO29 is set to A.SEL.

(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C. (B contact).