Code Material Viton (Standard) Polyurethane Buna-N Ethylene propylene No code UE BN EP Relieving Relieving Code Self Relieving (Standard) Non relieving 1 0 Main valve seat material Material Ports Material Vespel (Standard) PEEK Code Pressure gauge unit 4) Body material Code Brass 300 SS series 316 SS Material Code S No code PK B C S Ports Code Unit psig/bar MPa B V C V No code MPA 4P 4PN
(ASME B40.1 Grade B or better) psig/bar 4) (No code) Accuracy Cleanliness No oil ASME B40.1 level IV No oil Brass Polycarbonate Brass Phosphor bronze B Case Window Socket Bourdon tube Material MPa MPA 1.14 (29) 2.28 (58) 2.1 (53.5) 2.12 (54) NPT 1/4 0.42 (10.5) inch (mm) 3) Part number of pressure gauge itself.
R C R C (44) G1/2 E A H 2-P Port size B (S) E G1/2 2-M Thread depth N D A H B 2-P Port size 2-M Thread depth N D L L K K N.O.
B) Under the above conditions, adjust shim so that the space between the workpiece and the clamping block is about 0 mm. Theoretically there is no clamping force for holding a workpiece under this condition. C) In order to generate clamping force from the state described in step B, insert additional shim.
distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1
Ambient temp. 500 Heating capacity [W] Heating capacity [W] 400 40 40 400 32 32 300 300 25 25 5 5 200 200 100 100 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR010-A-20-) 9.5.4 HRR010-W-20400 400 Facility water temp.
Signal contents 1-2 Unused 3 Terminal A of resistance temperature detector 4 Terminal B of resistance temperature detector 5 Terminal B of resistance temperature detector 1 2. Communication connector D-sub 9 pin (socket) Holding screw: M2.6 E 6 Contact a for output cutoff alarm (open when alarm occurs) 7 Common for output cutoff alarm 9 15 10 11 12 13 14 Pin no.
Conditions: Supply pressure 0.7MPa Set pressure 0.2MPa Flow rate 0 l/min (ANR) Conditions: Back pressure 0.5MPa Conditions: Supply pressure 0.5MPa IR2000-02 IR2000-02 IR2000-02 0.204 0.5 0.2 Set pressure MPa Set pressure MPa Set pressure P2 MPa 0.4 0.202 Setting point 0.15 0.3 0.200 0.1 0.2 0.198 0.05 0.1 0.196 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8 0.7 0.9 1.0 0 100 200 300 400 0 100 200 300 400
0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
l (mm) l 300 200 300 MGTL80 P = 0.5MPa m 200 MGTM80 100 P = 0.5MPa Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 75st 50st 25st Larger than 50st 30 20 50 40 25, 50st 10 30 5 4 3 2 20 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5MPa 100 P = 0.5MPa Larger than
Weight g 65 65 25 15 15 B side traveling parallelism to A side Refer to Graph 1.
11 M6 x 1 depth 11 45 50.5 53 62 45 51.5 53 62 10 8.5 9 11.5 15.5 17.5 18.5 23 32.5 37 38.5 43 2.5 0 0 6 5 5.5 7 8 36 40 45 53 6 7 8 11 54 68 86 104 26 42 54 64 5 to 300 5 to 300 5 to 300 5 to 300 Rc, NPT, 1/8 Rc, NPT, 1/8 M8 x 1.25 depth 13 M8 x 1.25 depth 11 Rc, NPT, 1/8 M10 x 1.5 depth 15 M10 x 1.5 depth 14.5 KA H2 K MM MM1 NA NB NC ND NE NG NH NH1 NI NJ NS NY P S ZZ ZZ1 NF Model 10 12
LXPB2SB-B LXPB5SA-B LXPB2BC-B LXPB5BC-B LXPB2BD-B LXPB5BD-B LXPB2SA-B 5 phase to 200 2 phase to 200 5 phase to 100 2 phase to 30 5 phase to 30 2 phase to 80 5 phase to 80 2 phase to 100 Sanyo Denki Co., Ltd. 5 phase to 200 2 phase to 200 5 phase to 100 2 phase to 30 5 phase to 30 2 phase to 80 5 phase to 80 2 phase to 100 LXSH5SB LXSH2SB LXSH5SA LXSH2SA LXSH5BC LXSH2BC LXSH5BD LXSH2BD LXSH5SB-B
Maintenance check Model Connect(Flange) 2B/3B 8B C 2B/3B/4B 500 A 300 B 300 D 1300 E 1430 F 1520 G 20 H 720 M16 X l 400 Anchor bolt Caution M20 X l 500 AMD800 AMD900 400 550 560 745 300 300 1320 1380 1480 1610 1585 1740 24 24 q The replacement interval for the element for models AMD150 to AMD850 is when the pressure drop reaches 0.1MPa or after 2 years of operation, whichever comes first.
LXPB2SB-B LXPB5SA-B LXPB2BC-B LXPB5BC-B LXPB2BD-B LXPB5BD-B LXPB2SA-B 5 phase to 200 2 phase to 200 5 phase to 100 2 phase to 30 5 phase to 30 2 phase to 80 5 phase to 80 2 phase to 100 Sanyo Denki Co., Ltd. 5 phase to 200 2 phase to 200 5 phase to 100 2 phase to 30 5 phase to 30 2 phase to 80 5 phase to 80 2 phase to 100 LXSH5SB LXSH2SB LXSH5SA LXSH2SA LXSH5BC LXSH2BC LXSH5BD LXSH2BD LXSH5SB-B
SOL. location A B A B A B A B () A B () () 0 1 2 3 4 5 6 Double Double Single SI unit A side B side 3 position A B A B B A B A B A VQC Double Double Single SI unit A side B side 3 position Stations 1 2 3 4 5 SQ The places of asterisk are not used. 3 position uses two stations for wiring.
Note 4) Values for the low wattage (0.5 W) specifications. 2 position double (Double solenoid) (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Metal seal Rubber seal 3 position closed center 4 position dual 3 port valve (B) 3 position pressure center (A) 4 (B) 2 (A) 4 (B) 2 4 2 5 3 1 1 (P) 5 (R1) 3 (R2) N.O.
Static moment M2 = m g (L1 + B) 103 m x g = 1 9.8 (50 + 48) 103 Review M2. Since M1 and M3 are not generated, review is unnecessary. = 0.96 [Nm] 2 = M2/M2 max = 0.96/4 = 0.24 M Guide shaft mounting surface L1 B We = 5 x 103m g U = 5 x 103 1 9.8 300 = 14.7 [N] Me3 = 1/3 We(L2 + A) 103 3.
Note2) A (set) side energization : A light (orange) illuminates, B-(reset) side energization : B light (green) illuminates.