SMC Corporation of America
Elite Part Number Search
Search Results "CDG3DN50-250-M9BAZS-C"

Snap ring Type C 8 for axis Type C 10 for axis Type C 10 for axis Type C 14 for axis m 1.5 1.25 1.25 1.75 t 0.9 1.15 1.15 1.15 Part no.

CD-MU02 CD-MU03 CD-MU04 CD-MU05 (mm) 25 C shape for axis8 C shape for axis10 33(10) 32 32(5) 40 36(5) 50 38(0) 63 Size C shape for axis10 L(d) 49(0) C shape for axis14 If the cylinders must be operated with the mounting pitch less than indicated above, they must be shielded with steel plates or magnetic shield plates (Part No.: MU-S025). Contact SMC for details.

COM C COM C is receiving data: Lights up COM C is having no data to receive: Goes off COM D COM D is receiving data: Lights up COM D is having no data to receive: Goes off : It is lit when input unit is connected and communicating normally. 19 18 Display/ Switch Setting (continued) Switch setting Make sure that switch setting is performed with power supply turned off.

All data given in a technical specification sheet is based on 25[C]. The temperature range is dependent on the product series. Normally SMC products are rated from 0 to 50[C] or 0 to 60[C]. The failure predict function allows the user to anticipate possible maintenance requirements. How does it work?

RLQ MLU View A-A' ML1C DStandard Stroke B AF AP E A AA AB AC AD AE BP BZ C D F G GC Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 32 35 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 28 135 118 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 19 104 75 37 40 50 29 160 140 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5

RLQ MLU View A-A' ML1C DStandard Stroke BP BZ C D E F G GC A AA AB AC AD AE AF AP B Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 135 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 118 28 35 32 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 104 19 75 160 50 140 29 40 37 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5

, 300, 350, 400, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350

With timer Grommet 3 wire(NPN) IC 5V, 12V G59F With diagnostic output (2 color) 4 wire(NPN) Latch with dianostic output (2 color) H7LF *Lead wire length 0.5m (Example) B80C 5m Z (Example) B80CZ 3m Z (Example) B80CL N (Example) B80CN * : Manufactured upon receipt of order Stroke Long stroke (mm) Standard stroke (mm) Model Bearing Bore size (mm) 20 25 32 40 50 75, 100, 125, 150, 200 250

Both directions Lock direction MXW MXP Stroke Bearing Standard stroke (mm) Long stroke (mm) Bore size (mm) MG Model MGP 20 75, 100, 125, 150, 200 250, 300, 350, 400 MLGCM Slide bearing 25 350, 400, 450, 500 MGQ 75, 100, 125, 150, 32 350, 400, 450, 500, 600 MLGCL Ball bushing bearing 200, 250, 300 40 350, 400, 450, 500, 600, 700, 800 MGG * Middle strokes and short strokes other than shown

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Leakage test result a t e l u g c Stainless steel linear guide & low particulate generation vacuum grease e i 2 t n r a e CX p r a 0.0 10 0 20 10 w 10-10 0 5 10 t i o o n L DTime [min] Operation cycles -X e e a a l l k k a t e l u w w g a a c 2 e i o

Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.

Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.

GC GA XAH7 depth XL 2-Rc P PB A + Stroke E B + Stroke FA FB C + Stroke PA + Stroke GB Q G J K IE S XAH7 depth XL (mm) MLGPM, MLGPL common dimensions Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB GC H HA IA IB IC ID IE 14 11 100 44 16 12 44 54 10 120 M6 34 52 14 4 14 40 25, 50, 75 100, 125, 150, 175 200, 250, 300, 350 12 13 107 44 20 16 47 64 148 M8 35 64 19 50 11 7 14 115 49 20

Colors indication Color Black Clear Blue White Symbol B C BU W Color Yellow Red Green Orange Symbol Y R G YR Colors other than Black are made to order only.

Vacuum Area Diameter (Vacuum pressure: 84 kPa) after Vacuum Suction by Vacuum Pad (mm) Flat U Flat with ribs C Bellows B Deep D Large size H Type Large size bellows HB Material Size Part no.

D E F G H J K L Anchor bolt 406.4 609 609 609 962 962 962 1216 1216 361 510 510 510 824 824 824 1019 1019 440 650 650 650 1080 1080 1080 1300 1300 1268 1258 1978 2278 1550 2160 2770 2558 3288 1000 945 1340 1340 1100 1550 1650 1700 1700 550 645 740 740 750 750 750 850 850 6 9 9 9 12 12 12 16 16 460 665 693 693 1162 1162 1162 1416 1416 19 19 19 19 19 19 19 27 27 80 M16 x l 250 M16 x l 250 M16

ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Standard pressure: 100 kPa Standard pressure: 100 kPa Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.4 0.6 Standard pressure Standard pressure 0.5 mm 0.25 mm Detection distance (mm) Detection distance (mm) 0.5 0.3 0.4 0.2 0.3 0.15 mm 0.15 mm 0.2 0.1 0.1 0.03 mm 0.01 mm 0 0 50 0 250 200 150 100 250

250 250 Lead wire length D-B31 3 m (L) 268 268 268 5 m (Z) 462 462 462 Contacts protection resistance () () Reed switch Neon bulb Current limiting resistance Lead wire length In case of the grommet type (J type), the lead wire length is 0.5 m.

Converter size Cylinder bore size (mm) Cylinder piston speed (mm/s) Step (4) Select the size of valve unit 310 or more 32 CCT40 200 or more 40 Using data (C), as a reference, select the size of a valve unit by determining whether it meets the desired cylinder operating speed.

Faster Average speed [mm/s] Measuring conditions Supply pressure: 0.55 MPa 0 50 100 150 125-250 160-300 Bore size-Stroke 200-300 250-450 320-530 Speed adjustment rotary switch set value 0 5 9 Mounting: Vertical downward Load: no-load Operating direction: Upward *1 The average speed value is the stroke divided by the full stroke time.