Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 750, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Series: LEKFS, Size: 32, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 450
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 45 95 150 170 250 350 450 770 960 Surface: Munsell N-5.5, Inner surface: Non coated Safety valve (1 pc.) R 1/2 R 3/4 R 11/4 R 2 R 1 Accessory (2) Rc 1/2 Valve for drainage (1 pc.) Pressure gauge (1 pc.)
Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 450
Series: LEKFS, Size: 40, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 450, Motor Option: B (with Lock), Seal Band Stopper: N [Roller Type Seal Band Stopper [Grease Free]], Actuator Cable Type, Length: R5 (5), Controller: C9F (EtherNet/IPâ„¢ with STO Sub-Function
e-t Tr' '],i(\tnralr.s Lightweight and Compact Built-in Auto Drain Port Sizes 1/4" 2" NEW PRODUCT GUIDE Ambient Dryer Series AMG Allows'Point of Use" installation wherever moisture needs to be removed from air supply. 99p/o of all Moisturc Can Be Removed Wide Range of Port Sizes Moisture can be removed at the air inlet or the Port sizes of 114 2 are available to meet air end of fie air line
MC NFB Servomotor HC-PQ Power supply Single phase 200VAC (Type A) or Single phase 100VAC (Type A1) C P U L1 U V V W Servo amp SM L2 W MR-CA E or MR-CA1 The length of the cable between the controller and servo amp is 2m or less.
One-touch fitting 6 One-touch fitting 8 One-touch fitting Rc(PT)1/4 8 One-touch fitting 10 One-touch fitting Applicable series Type of actuation SY3000 2 position single (A) 4 (B) 2 1 SY5000 5 (EA) 3 (EB) 1 (P) 2 position double (A) 4 (B) 2 2 SY7000 5 (EA) 3 (EB) 1 (P) 3 position closed center (A) 4 (B) 2 3 Manual override 5 (EA) 3 (EB) 1 (P) 3 position exhaust center Nil: Non-locking push type E:
Station Address S1 S2 00H to 02H: Disabled 0 0 to 2 (Do not use these addresses.) 03H (Factory setting) 0 3 04H 0 4 EFH E F F0H to FFH: Disabled F 0 to F (Do not use these addresses.) (2) Settings of the DIP Switch S3 The following table shows the settings of the DIP switch (S3). Switch No.
Series: LEKFS, Size: 32, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 450
Series: LEKFS, Size: 32, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 450
Dust-tight, Jet-proof Enclosure: Enclosure: Optional IP65 rating Optional IP65 rating Cylinder operation speed Cylinder bore size mm Valve width mm Cv Rubber seal (Metal seal) Cylinder speed mm/s Individual wiring style
Magnet: D (Built-in), Mounting: D (Double Clevis), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification