Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Hardness and deterioration of connected tubes e. Air leakage 192

: Push locking slotted style R port P/E port Pilot valve exhaust is centralized to main valve.

6For PROFIBUS DP K e For EtherNet/IPTM, PROFINET, EtherCAT, Ethernet POWERLINK K w and K e are used in combination with each other. K !4For PROFIBUS DP Terminating resistor Plug (Male) K tFor CC-Link K oFor DeviceNetTM Socket (Female) K uFor CC-Link K !2For DeviceNetTM Connects to the communication port of the communication unit connected at the end K !3 K !8 K !

Unit No. : Refer to the "Unit address order" of (A) Master unit setting (page 22) or (A) Slave unit setting (page 38) for IO mapping position. -52No.EX-OMV0017 (e).

RLQ MLU View A-A' ML1C DStandard Stroke B AF AP E A AA AB AC AD AE BP BZ C D F G GC Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 32 35 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 28 135 118 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 19 104 75 37 40 50 29 160 140 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5

RLQ MLU View A-A' ML1C DStandard Stroke BP BZ C D E F G GC A AA AB AC AD AE AF AP B Bore size (mm) 20 25 32 40 Stroke range (mm) -X 11 depth 8 26.5 73.5 6.8 75, 100, 125, 150, 200 M6 x 1 depth 12 13 94 16.5 70 135 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 50 118 28 35 32 12 14 depth 10 31.5 86.5 8.6 M8 x 1.25 depth 16 16 104 19 75 160 50 140 29 40 37 16 2075, 100, 125, 150, 200, 250, 300 14 depth 10 31.5

Cylinder port is located at U side of body. 3(R) EXH port L n Dimensions Formula L1 = 11n + 15.5, L2 = 11n + 28 n: Station (Maximum 16 stations) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 37.5 50 75 85.5 L1 L2 (L3) (L4) 26.5 39 62.5 73 48.5 61 87.5 98 59.5 72 100 110.5 70.5 83 112.5 123 81.5 94 125 135.5 92.5 105 125 135.5 103.5 116 137.5 148 114.5 127 150 160.5 125.5 138 162.5 173 136.5 149

VZ (A) 2 (A) 2 VS 3 (R) 1 (P) 3 (R) 1 (P) r e w q r e w q N.O. N.O. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Component Parts Material Description Notes No.

Determination of kinetic energy of load (E) E > Es E Es Bore size determination Tentative determination of L type W V 2 E = () 2 1000 Note 2) E > Es Determination of pressure (P) when making intermediate stop P > Ps P Ps Consider made-to-order products, depending on an operating condition. Tentative determination of L type (For intermediate stops, refer to page 1515.)

M10 x 1.25 M10 x 1.5 M12 x 1.25 M12 x 1.5 M12 x 1.75 M14 x 1.5 M16 x 1.5 M16 x 2 M18 x 1.5 H 5 5 6 6 6 7 7 7 8 10 10 11 B C 15 15 19.6 19.6 19.6 21.9 21.9 21.9 25.4 27.7 27.7 31.2 JC20-8-100 JC20-8-125 JC32-10-100 JC30-10-125 JC25-10-150 JC40-12-125 JC40-12-150 JC40-12-175 JC40-14-150 JC50-16-150 JC63-16-200 JC63-18-150 DA00207 DA00169 DA00141 DA00142 DA00140 DA00145 DA00146 DA00143 DA00148

) x PC F=-q x PA+r x PB+(w-e) x PC F=q x PA q, w and e are piston areas.