SMC Corporation of America
Elite Part Number Search
Search Results "CDLG1BN40-550-P"

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(m)

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: M9B, Lead Wire Length(m): 0.5, The number

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: NPT, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 250, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches

/cycle (Standard) Operating time Power source 100, 200 VAC Hz, Other 4 W IN: Rc , OUT: Rc 550 g 50 60 Power consumption 3 8 1 2 Port size 3 8 Weight If the operating cycle is twice in a minute (op. time 2 sec. x 2) operating time is 4 sec. each minute.

Manhole Air inlet Inspection hole Air inlet socket Drain Drain Anchor bolt mounting hole Anchor bolt mounting hole Model Air connection Socket Flange A B C D E F G H J K L Anchor bolt 406.4 609 609 609 962 962 962 1216 1216 361 510 510 510 824 824 824 1019 1019 440 650 650 650 1080 1080 1080 1300 1300 1268 1258 1978 2278 1550 2160 2770 2558 3288 1000 945 1340 1340 1100 1550 1650 1700 1700 550