(100) (2)2mm 2 D (3) 40 50mm ()100mm 100 -33No.JXC-OMT0001CN-C 5.
Rated coil voltage DC 5 24 VDC V V V V 6 12 VDC V V V V + G Grommet (Lead wire length: 300 mm) V V V V D Type D (DIN terminal/With connector) V V V V Y Type Y (DIN terminal/With connector)*2 V V V V DO Type D (DIN terminal/Without connector) V V V V YO Type Y (DIN terminal/Without connector) V V V V + y e Electrical entry u f Light/ surge voltage suppressor Nil None V V V V Z With light/surge
D-M9V, D-M9WV D-M9A D-M9AV A B W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable
Electrical entry TT is approved for Class I, II, III, Division 1, Groups A, B, C, D, E, F, G. Electrical entry L and LL is approved for Class I, Division 1, Groups A, B, C, D. 4.
cable O.D. 6 to 8 (D, DL) Pilot port B (Air operated) L (Terminal with indicator light: DL) M (Conduit terminal: T) K (DIN terminal: D) I (Grommet: G) J (Conduit: C) 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H I J K L M Model VNB5-32F VNB6-40F VNB7-50F 1 8 1 4 1 4 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 244 259.5
Fig.1-3 shows the location of the communication port. 14 1 Contact input / output signal connector D sub 25 female pin (socket) type 25 13 1 6 Serial communication connector D sub 9 female pin (socket) type 9 5 Fig.1-3 Communication port HRS400-A-46 1.3 Communication port 1-5 DOC1003626 Chapter 1 Read before using 1.4 Touch panel flow Press the [Comm.
/PL / OSSD SIL 2 2 2 3 3 3 3 3 SIL CL 2 2 2 3 3 3 3 3 * 2 2 4 3 4 ** 4 3 Cat. 3 PL d d d e d e e d *:Cat. 3 EN13849-2 2 N.O. **:Cat. 18 No.EX##-OMY0006CN 3.3.8. SI 0 SI 0 A SI 1. 2.I/O 3.SI 4. 5. 10 0 I/O 0 "0"= SI 72 72 SI 72 SI SI 16 SI SI SI SI 0 16 19 No.EX##-OMY0006CN SI SI SI 16 SI SI 20 D 3.3.9. GSDMLFDCML 3.4.
Size ASF Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Max.
(Cable length) Product image Both straight Both angle Number of functional poles M12: 4 pins Key type M12: D-coded 1 2 1 (Yellow) : TD+ 2 (White) : RD+ 3 (Orange) : TD 4 (Blue) : RD Pin assignment 3 4 Plug, D-coded (Viewed from the plug) Fixed cable length 0.5 m, 1 m, 2 m, 3 m, 5 m, 10 m Wiring Cable O.D. 6.5 mm Conductor nominal cross section 0.34 mm2/AWG22 Wire O.D.
side traveling parallelism to B side C side w LEKFS25 0.04 0.02 LEKFS32 0.04 0.02 LEKFS40 0.04 0.02 D side * Traveling parallelism does not include the mounting surface accuracy.
Weight g Model d T D1 H D2 D3 L1 L4 L2 L3 Min. Max.
H A 30 ZPNA-M22 34.6 Bolts Dimensions (mm) A 11 d M3 x 0.5 12 7 M4 x 0.7 B 5.5 L 8 8 10 15 8.5 M5 x 0.8 13-11-82
Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 5 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3
Dimensions Metric size Inch size Model d Weight g D1 D2 L1 L2 L3 Model d Weight g D1 D2 L1 L2 L3 Max. Min. M1 Max. Min.
Controller (VYU5-D) External appearance of exclusive controller RUN1 STOP START SEL. SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.
Protrusion of Auto switch Lead wire type In-line entry Perpendicular entry Illustration MHZ Auto switch Hysteresis L L Auto switch operating position (ON) Finger position MHF Auto switch operating position (OFF) MHL D-M9 D-F9W D-M9V D-F9WV Model MHR Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close 4.5 4.5 4.5
Protrusion of Auto switch Lead wire type In-line entry Perpendicular entry Illustration MHZ Auto switch Hysteresis L L Auto switch operating position (ON) Finger position MHF Auto switch operating position (OFF) MHL D-M9 D-F9W D-M9V D-F9WV Model MHR Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close 4.5 4.5 4.5
YX Edition B Edition D The HRR010 (air-cooled type, water-cooled type) has been added. Number of pages has been increased from 36 to 44. YV Edition C Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.