Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
(Mounting thread) Note) If the fitting attached to the port interferes with the auto switch, please use the extension fitting assembly supplied with the air gripper. 4 x AA thread depth AB (Mounting thread) Prepared hole diameter AC through (Mounting hole) Note) AD depth AE AF depth AG S H When open AS When closed AR When closed AT M T D P B R N G Q F E C A 2 x AH thread depth AJ (Mounting
MB MC KA MA C N K N S + Stroke H B ZZ + Stroke Stroke range Bore size (mm) I J K M B D C E KA GA GB H 40 50 63 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 10 14 14 45 55 68 21 26 32 36 46 53 34.5 40 46.5 40 45 50 46 55 66 59 71 82 23.5 28 34.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) MM XA XL Y ZZ MA MB MC N P S 40 50 63 M6 x 1.0 M8 x 1.25 M8 x 1.25 12 16 16 6 6 6 9.5 12.5
Bit 3 of SW2 SW1 Station Address Bit 3 of SW2 SW1 Station Address OFF 0 Disabled ON 0 50H OFF 1 41H ON 1 51H OFF 2 42H ON 2 52H OFF 3 43H ON 3 53H OFF 4 44H ON 4 54H OFF 5 45H ON 5 55H OFF 6 46H ON 6 56H OFF 7 47H ON 7 57H OFF 8 48H ON 8 58H OFF 9 49H ON 9 59H OFF A 4AH ON A 5AH OFF B 4BH ON B 5BH OFF C 4CH ON C 5CH OFF D 4DH ON D 5DH OFF E 4EH ON E 5EH OFF F 4FH ON F 5FH Turn the power
(3) 5A 10A R134a(HFC) AC100V/200V g 2805 2905 35010 Rc3/4 Rc1 10mm 1 2 kg 44 47 71 kW 7.5 11 15 1ANR 2065% 2 3 30mA 4() IDU Series 6-1 6 2 IDX-OM-W023 6 6-2 GWP (GWP) Regulation (EU) No 517/2014 IPCC AR4) R134a 1,430 1,430 R404A 3,922 3,920 R407C 1,774 1,770 R410A 2,088 2,090 (1) (2) IDU Series 6-2 GWP 6 3 IDX-OM-W023 6 6-3 A B E D Q Guige Guige G C Guige Guige [
Note 2) 1 (P) 3 (R) Note 3) 1.13-4 Series VQD1000 Construction JIS Symbol (A) 4 (B) 2 Part name Component Parts Note Material No. q w e r t y u i o !0 Solenoid coil assembly Sub-plate Body Spool valve Poppet Guide ring Return spring Manual override Gasket Round head screw VQD1000-S-M5(Base mounted only) Aluminum ZDC 1 (P) 3 (R) q u e !
e-t Tr' '],i(\tnralr.s Lightweight and Compact Built-in Auto Drain Port Sizes 1/4" 2" NEW PRODUCT GUIDE Ambient Dryer Series AMG Allows'Point of Use" installation wherever moisture needs to be removed from air supply. 99p/o of all Moisturc Can Be Removed Wide Range of Port Sizes Moisture can be removed at the air inlet or the Port sizes of 114 2 are available to meet air end of fie air line
Series: LEKFS, Size: 32, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 450
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 45 95 150 170 250 350 450 770 960 Surface: Munsell N-5.5, Inner surface: Non coated Safety valve (1 pc.) R 1/2 R 3/4 R 11/4 R 2 R 1 Accessory (2) Rc 1/2 Valve for drainage (1 pc.) Pressure gauge (1 pc.)
Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 450
Series: LEKFS, Size: 40, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 450, Motor Option: B (with Lock), Seal Band Stopper: N [Roller Type Seal Band Stopper [Grease Free]], Actuator Cable Type, Length: R5 (5), Controller: C9F (EtherNet/IPâ„¢ with STO Sub-Function
e-t Tr' '],i(\tnralr.s Lightweight and Compact Built-in Auto Drain Port Sizes 1/4" 2" NEW PRODUCT GUIDE Ambient Dryer Series AMG Allows'Point of Use" installation wherever moisture needs to be removed from air supply. 99p/o of all Moisturc Can Be Removed Wide Range of Port Sizes Moisture can be removed at the air inlet or the Port sizes of 114 2 are available to meet air end of fie air line
MC NFB Servomotor HC-PQ Power supply Single phase 200VAC (Type A) or Single phase 100VAC (Type A1) C P U L1 U V V W Servo amp SM L2 W MR-CA E or MR-CA1 The length of the cable between the controller and servo amp is 2m or less.
One-touch fitting 6 One-touch fitting 8 One-touch fitting Rc(PT)1/4 8 One-touch fitting 10 One-touch fitting Applicable series Type of actuation SY3000 2 position single (A) 4 (B) 2 1 SY5000 5 (EA) 3 (EB) 1 (P) 2 position double (A) 4 (B) 2 2 SY7000 5 (EA) 3 (EB) 1 (P) 3 position closed center (A) 4 (B) 2 3 Manual override 5 (EA) 3 (EB) 1 (P) 3 position exhaust center Nil: Non-locking push type E:
Station Address S1 S2 00H to 02H: Disabled 0 0 to 2 (Do not use these addresses.) 03H (Factory setting) 0 3 04H 0 4 EFH E F F0H to FFH: Disabled F 0 to F (Do not use these addresses.) (2) Settings of the DIP Switch S3 The following table shows the settings of the DIP switch (S3). Switch No.
Series: LEKFS, Size: 32, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 450
Dust-tight, Jet-proof Enclosure: Enclosure: Optional IP65 rating Optional IP65 rating Cylinder operation speed Cylinder bore size mm Valve width mm Cv Rubber seal (Metal seal) Cylinder speed mm/s Individual wiring style