SMC Corporation of America
Elite Part Number Search
Search Results "CNA2D63TN-50-D"

] [mm] 1) 30 50 100 150 200 250 300 30 50 100 150 200 250 300 350 400 30 50 100 150 200 250 300 350 400 450 500 (kg) 0.580.62 0.73 0.87 0.98 1.09 1.20 1.181.25 1.42 1.68 1.86 2.03 2.21 2.382.56 2.09 2.20 2.49 2.77 3.17 3.46 3.74 4.03 4.32 4.60 4.89 LEY 16 D LEY 25 D LEY 32 D [mm] 1) 30 50 100 150 200 250 300 30 50 100 150 200 250 300 350 400 30 50 100 150 200 250 300 350 400 450 500 (kg)

R A: 0.19 A P: 0.13 VP VG Grommet (G) Body Ported Base Mounted VZ300 VP S070 M5 x 0.8 0.66 2 3 (A R) VQ L plug connector (L) VKF (Standard) VQZ 100 VAC 50/60 Hz With surge voltage suppressor (G) (L) (M) (D) With light/ surge voltage suppressor (L) (M) (D) VZ500 200 VAC 50/60 Hz 24 VDC VZ VS 2.5 2 3 (A R) (Option) N. C. N. O.

, 75, 100, 125, 150, 200 201 to 350 301 to 400 301 to 450 301 to 800 D-C7/C8 D-B5/B6 D-H7 D-G5NTL 1500 10 mm 15 mm 25, 50, 75, 100, 125, 150, 200, 250, 300 D-B59W 15 mm 20 mm Note 1) Intermediate strokes other than the above are produced upon receipt of order.

D. Holding Force O. D. Holding Force MHKL2-12D MHKL2-12D 20 25 Pressure 0.6MPa Pressure 0.6MPa 20 Holding force N Holding force N 15 0.5MPa 0.5MPa 15 0.4MPa 10 0.4MPa 10 0.3MPa F F 0.3MPa 5 5 0.2MPa 1N = 0.2248 lbf = 0.102 kgf 1MPa = 145 psi = 10.2 kgf/cm2 0.2MPa 0 0 50 50 10 20 30 40 10 20 30 40 Holding point L mm Holding point L mm O. D. Holding MHKL2 series I. D.

/60Hz 200V AC 50/60Hz 110V AC 50/60Hz 220V AC 50/60Hz 24V DC 12V DC 240V AC 50/60Hz Other 1 2 3 100V AC 50/60Hz 200V AC 50/60Hz 110V AC 50/60Hz 220V AC 50/60Hz 24V DC 12V DC 240V AC 50/60Hz Other 1 2 3 Electrical entry 4 4 Option Grommet Conduit Conduit terminal DIN connector DIN connector with indicator light G C T(1) D DL 5 6 5 6 7 7 Electrical entry/Indicator light and surge voltage suppressor

side D D D D D D SS5V1-16S3AD-06B-C61 set (manifold part no.)

D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V Applicable auto switches D-P3DWA Bore size (mm) 50 to 80 50 to 80 Surfaces with auto switch mounting slot Surfaces with auto switch mounting slot Auto switch mounting surfaces q Insert the mounting bracket into the mating groove of the cylinder tube. w Check the detecting position of the auto switch and fix the auto switch firmly with the hexagon socket

P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 10-4-7 8 Series CQ2Y Dimensions/63 to

D40 20.5 23.5 28.5 M14 x 1.5 50 26 28.5 33.5 M18 x 1.5 -X (mm) Without auto switch With auto switch A B A B 20U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75

Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 NBA088S NBA106S BGS1 -032S BAF -04S BAF -05S BAF -06S BAF -08S BAF -10S D-G5BA Includes stainless steel mounting screws.

BMY3-016 Auto switch model Tightening torque D-M9l(V) D-M9lW(V) 0.10 to 0.15 210 Solid State Auto Switch Direct Mounting Type D-M9N(V)/D-M9P(V)/D-M9B(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.

Note 1) Note 2) Maximum available stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm) Model Long stroke (mm) 1 pc. 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 D-C7, C8 D-B5, B6 D-H7 D-G5N 15mm 10mm 1500 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 20mm 15mm 10mm D-B59W D-H7LF Note 1) Intermediate strokes other than the above are produced upon receipt

For 3 Axes Step Axis Movement mode Speed Position Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 Axis 2 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 0 Axis 3 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 Axis 1 INC

LXFH5 SB 1 S F9N Stroke Auto switch types Wiring/Output type Lead wire length (m) Contact Model Symbol Without auto switch Nil F9N F9P F9G F9H F9GL F9HL F9B F9NL F9PL F9BL Home position switch D-F9N D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL N.O.

Insert D at the end of the manifold part number.

20 100V CE1 PLC D-C73C 5 to 40 24V DC AC DC CE2 D-C80C IC circuit, Relay, PLC 50 24Vor less D-B53,A33 5 to 50 24V DC PLC ML2B 5 to 50 24V DC D-B54 D-A34 D-A44 5 to 25 100V AC ML1C 5 to 12.5 200V AC AC DC 50 Relay, PLC 24Vor less REA D-B64 25 100V AC 12.5 200V AC REC 5 to 40 2 color** D-B59W 24V DC RHC * Use contact protection box when using "D-C7" or "D-C8" type in the following conditions

D-M9mA D-M9mAV A B 12 5 2.5 16 5.5 3 20 6 6 25 6 7.5 32 8 8 40 11 9 50 11.5 11 63 13.5 13.5 80 16.5 18 100 19.5 21 Auto switch model Auto switch model D-M9mV Bore size Bore size U 12 19.5 16 21 20 23 25 24.5 32 28.5 40 31.5 50 36.5 63 43 80 52.5 100 59 Minimum Stroke for Auto Switch Mounting Operating Range [mm] [mm] Number of auto switches D-M9mV D-M9mWV D-M9mAV D-M9m D-M9mW D-M9mA 1 5

2, 4, 6, ) 10 15 60 60 + 45 (n 2) D-C73C D-C80C DH7C 10 15 65 (n 2) 2 15 + 50 ( ) 65 + 50 (n 2) (n = 2, 4, 6, ) (n 2) 2 15 + 50 ( ) D-B5/B64 D-G5NTL 10 15 75 (n = 2, 4, 6, ) 75 + 55 (n 2) (n 2) 2 20 + 50 ( ) D-B59W 15 20 75 (n = 2, 4, 6, ) D-A3 D-A44 D-G39 D-K39 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside