Search Results "CV3KL50-50-1"

Minimum Stroke for Auto Switch Mounting [mm] Auto switch model Number of auto switches Bore size 12 (10 x 2) 16 (12 x 2) 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) D-M9V 1 5 2 5 D-M9 1 5 Note 1) 5 2 10 Note 1) 10 D-M9W 1 5 Note 2) 2 10 Note 2) 10 D-M9WV D-M9AV 1 5 Note 2) 2 10 D-M9A 1 5 Note 2) 2 10 Note 2) Note 1) Confirm that it is possible

Tightening torque Nm 28 to 30 36 to 38 48 to 50 48 to 50 Tightening torque Nm 7 to 9 12 to 14 22 to 24 28 to 30 Thread Rc 3/4 Rc 1 Rc 1, 1/2 Rc 2 Thread Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 Supply voltage > Internal voltage drop of switch Minimum operating voltage of load 2. Apply a wrench only to the metal part of the piping when installing the flow switch onto the system piping.

for 1/4" (Inch size) N3: With One-touch fitting for 5/32" N7: With One-touch fitting for 1/4" N9: With One-touch fitting for 5/16" SX 000-50-3AP PG PH SX 000-50-4AFor 45(N) (Flat ribbon cable) SX 000-50-5ASX 000-50-6AT T1 For 45 (Terminal block) SX 000-50-7A1-6-110 111 Base Mounted Series SX3000/5000 How to Increase Manifold Bases (1) Loosen bolt (a) fixing the manifold base until it begins

X 1.5 47 50 65 31 15 145 115 M14 X 1.5 17 59 35 16 90 14 36 43 29 32 25 to 1000 Lube Non-lube Air-hydro 1/2 M30 X 1.5 50 47 75 15 31 161 128 M14 X .5 36 90 43 14 16 32 17 59 35 36 28 to 1000 3/4 M36 X 1.5 56 53 80 36 18.5 17 182 144 M16 X 1.5 20 40 90 59 43 14 39 36 40 32 to 1200 3/4 M40 X 1.5 60 63 41 90 115 18.5 204 162 M18 X 1.5 20 17 23 45 70 48 39 44 50 40 to 1200 3/4 1 Lube Non-lube

70 40 160 37 M8 165 85 12 9 125 110 176 160 16 18 107 50 75 150 115 82.5 45 194 42 M10 200 95 12 11 135 115 210 190 19 23 142 Bore size (mm) W WH W V U T S Z R Y Q X O P 20 25 32 40 50 30 23 36 40 86 12 26 140 12 80 21 30 M6 x 1 M5 x 0.8 30 25 44 47 98 13 31 153 12 80 21 37 M6 x 1 M5 x 0.8 25 28.5 50 53 112 16 38 161 12 82 21 37 M6 x 1 Rc 1/8 20 33 60 63 132 20 47 188 12 92 25 44 M8 x 1.25

, 75, 100, 125, 150 Relief type Vacuum suction type 1/8 25, 50, 75,100, 125, 150, 200 1/4 Not available 25, 50, 75, 100, 125, 150, 200, 250, 300 Non-lube Double acting, single rod Available Available 25, 50, 75, 100, 125, 150 1/8 25,50,75,100,125,150,200 1/4 25,50,75,100,125,150,200,250,300 Specifications Suction flow rate of vacuum suction type (Reference values) Bore size (mm) Item 20/25

(Including nut, screw, (spacer)) Applicable bore size (mm) 12 BQ-1 BQ-1 Cylinder series 40 BQ-2 BMU1-025 80 BQ-2 32 BQ-2 BMU1-025 50 BQ-2 BMU1-025 100 BQ-2 25 BQ-1 BMU1-025 140 BQ-2 160 BQ-2 125 BQ-2 BQ-1 20 63 BQ-2 BMU1-025 16 BQ-1 CDQ2 MDU RSDQ MK, MK2 CE1 CXT BQ-1 BQ-2 BQ-1 BQ-2 BQ-2 BQ-2 [Mounting screws set made of stainless steel] The set of stainless steel mounting screws (with nuts

and table moved to the end of the stroke W Horizontal load 100% Horizontal load 50% 200 100 Amount of deflection m 50 Load point distance Figure 1.

Ordering example) ZX1051-K15LOECN 1 pc. VJ10-20-4A-6 2 pcs. ZS-10-5A-50 1 pc. (For 110 VAC) 3A 36 VJ10 6 Ejector System/Recommended Model (The models below will have shorter deliveries.)

HRX-OM-W038 Contents Contents Chapter 1 Safety Instructions . 1-1 1.1 Before using the product . 1-1 1.2 Reading the Manual . 1-1 1.3 Hazards . 1-2 1.3.1 Level of hazards . 1-2 1.3.2 Definition of Serious injury and Minor injury . 1-2 1.3.3 Types of hazard labels . 1-3 1.3.4 Locations of Hazard Labels . 1-4 1.4 Other Labels . 1-5 1.4.1 Product Label . 1-5 1.5 Safety Measures . 1-5 1.5.1 Safety

Body through-hole 1. Body tapped Stroke (mm) Model Reed switch D-A9, D-A9V 10 20 30 50 75 100 MXF8 8 Solid state switch D-M9, D-M9V MXF12 12 2-color indication solid state switch D-F9W, D-F9WV MXF16 16 MXF20 20 8-6-1 2 Low Profile Slide Table Series MXF 8, 12, 16, 20 How to Order MXF 12 50 M9N S Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.

25 (1B) 40 (1 1/2B) 50 (2B) 25 (1B) 20 (3/4B) 570 7 500 20 115 37 400 267.4 230 510 915 1250 100 150 25 (1B) 40 (1 1/2B) 50 (2B) 25 (1B) 20 (3/4B) 570 7 750 20 130 50 400 267.4 230 510 1175 1510 100 150 25 (1B) 40 (1 1/2B) 50 (2B) 25 (1B) 20 (3/4B) 570 7 1000 20 150 64 400 267.4 230 510 1440 1775 100 150 40 (1 1/2B) 50 (2B) 65 (2 1/2B) 40 (1 1/2B) 25 (1B) 620 9 500 20 150 54 445 318.5 240

1/2 305 206 206 180 4 x 13 4 x 13 50 50 Drain port 1/4 100 200 100 400 674 200 696 (mm) A 481 520 444 477 B 394 429.8 394 429.8 C 3/8 1/2 3/8 1/2 D Note) 469 493 Booster regulator model The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.

{mm} L2=50 {mm} L2 {B L3 Item Load factors n Note (1) Max. movable load W B L2 Examine W.

For 4 Axes Step Axis Movement mode Speed Position Acceleration Deceleration Positioning/ Pushing Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 100 200.00 1000 1000 0 6.0 12.0 0.5 Axis 2 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 0 Axis 3 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 4 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 1 INC 500 250.00 1000 1000 1 0 0 20.0

thread depth 12 (N 1) x H G NN-M6 x 1 thread depth 12 Bottom through-hole 5.1 HH Bottom through-hole 5.1 GG H 7 depth 5.5 6H9 +0.030 0 F E 6H9 +0.030 depth 5.5 0 (mm) Model G F E Z NN N L K J HH H GG MXW16-125 99 157 110 345 1 5 64 43 141 45 31.5 MXW16-150 124 176 136 395 1 5 89 68 166 50 24 MXW16-175 151.5 202 163 445 2 6 114 93 191 45 45 39 MXW16-200 174 226 186 495 2 6 139 118 216 50

Straight type 49 1 V100 Cable length 1 500 mm 300 mm 2 3 4 7 1000 mm DIN Terminal Type 2000 mm 5000 mm 5 D V115 Light/surge voltage suppressor Rated voltage Nil Without light/surge voltage suppressor S Z With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) 5 24 VDC 6 12 VDC 50 60 1 100 VAC Hz 50 60 2 200 VAC Hz DOZ is not available.

8 1/8 1/8 1/4 WA 31 31 31 36 Y 20 20 20 23 Z 8 8 8 10 LD 4 4 4 4 LT LS 25 28 28 30 Bore size 40 47 47 54 13 17 17 22 26 32 32 41 26 26 26 31 41 45 45 50 5 6 6 8 8 8 8 10 21 25 25 27 149 153 155 191 The bracket is shipped together.

The position ranges should be set as follows: Position 1 Position 2. Part No. Range Resolution LAT3-10 0 to 10 Refer to the 0.03 LAT3-20 0 to 20 Area Range table on the LAT3-30 0 to 30 right. LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated.

D-X 100 Lateral load F (N) 2080 10 Data 63 50 Operating pressure 0.5 MPa Operating pressure 0.4 MPa 40 32 25 Graph (1) 1000 20 1 10 100 300 Stroke + Eccentric distance (mm) Cushion Needle Adjustment 100 100 Load weight kg Caution 80 63 50 1.