mounting Bottom mounting Application Example Assembly lines, inspection lines etc. with turning operations Front mounting Side mounting Series Variations Bearing type Bore size (mm) Standard stroke (mm) Model Slide bearing MGTM 63 80 25, 50, 75, 100, 125, 150, 175, 200 Ball bushing bearing MGTL 100 8-24-2 3 Cylinder with Turntable Series MGT 63, 80 100 How to Order MX MTS M 63 50 11 Y59A S S A93
Lead wire length (m) Load voltage Indicator light Special function Wiring (Output) Electrical entry Type Applicable load Auto switch model 0.5 (Nil) 3 (L) 5 (Z) DC AC A90 IC circuit No 100 V or less 5 V, 12 V Reed switch Relay, PLC 2-wire 24 V Grommet A93 Yes 100 V 12 V M9N 3-wire (NPN) IC circuit Solid state switch 5 V, 12 V Relay, PLC M9P Grommet 3-wire (PNP) 24 V Yes M9B 2-wire
Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) Y59BL 5 m Z (Example) F9NWZ Since there are other applicable auto switches than listed, refer to page 8-15-44 for details.
Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) Y59BL 5 mZ (Example) F9NWZ Refer to page 8-12-24 for details on other applicable auto switches than listed above.
Load voltage Internal voltage drop (illuminated load current load when ON) range AC DC 24V or less 50mA Relay D-A90 AC DC 48V or less 40mA Not provided PLC D-A90V IC circuit AC DC 100V or less 20mA D-A93 2.4V or less (up to 20mA) 3V or less DC24V 5 to 40mA D-A93 Provided Relay (up to 40mA) D-A93V PLC D-A93V 2.7V or less AC100V 5 to 20mA 2.7V or less D-A96 D-A96V DC4 to 8V 20mA 0.8V or less
Applicable model: D-A93 4. Mount a switch at the center of the operating range.
Standard stroke 12 16 20 25 How to Order . 1 5, 10, 15, 20, 25, 30 5, 10, 15, 20 25, 30, 35, 40, 45, 50 Note 1) Single Rod Double Rod Return/Extend Single Rod Accessories . 5 Long stroke 12 16 20 Double Acting Single Acting Double Acting 35, 40, 45, 50, 75, 100 75, 100, 125, 150 175, 200 75, 100, 125, 150 175, 200, 250, 300 Construction . 6 25 Dimensions . 7 & 8 Reed switch D-A90, A90V D-A93
B Reverse the mounting direction A Reed switch D-A90(V), D-A93(V), D-A96(A) mm Auto switch mounting Switch operating range Stroke (mm) 20 45 25 51 31 Type 25 50.5 30.5 30 59 39 10 35 15 40.5 20.5 Caution A B A B A B MXP10 Tool for auto switch mounting MXP12 5 Use the screwdriver with grip diameter 5 to 6 mm when set screw (attached to auto switch) is set.
24V With Grommet Diagnosis indication (2-Color indicaiton) 12V F9NWV F9NW 3-wire (NPN) F9PWV F9PW 3-wire (PNP) F9BWV F9BW 2-wire PLC: Programable logic controller Lead wire length 0.5m " " (Example)A93 3 m " L " A93L Refer to page 177 to 179 for additional information on auto switches.
Load voltage Indicator light Lead wire length (m) AC DC Auto switch model Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 5(Z) 0.5(Nil) 3(L) Perpendicular In-line Reed switch Solid state switch IC circuit 3-wire (NPN equivalent) A96 A96 5 V Grommet Yes Relay, PLC 2-wire A93V A93 100 V 24 V 12 V M9NV M9N 3-wire (NPN) IC circuit 5 V, 12 V M9PV
Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) Y59BL 5 mZ (Example) F9NWZ Refer to page 8-12-24 for details on other applicable auto switches than listed above.
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes, from
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 32MM CY1S DOUBLE-ACTING, ACTUATOR, CY1S GUIDED CYLINDER, LD, 32MM CY1S DOUBLE-ACTING, 9.47987 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 32MM CY1S DOUBLE-ACTING, ACTUATOR, CY1S GUIDED CYLINDER, LD, 32MM CY1S DOUBLE-ACTING
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM CY1S SLIDE BEARING, ACTUATOR, CY1S GUIDED CYLINDER, MM, 40MM CY1S SLIDE BEARING, SeriesDescriptionModelActionNoteVol. no. (for std model)CY1Magnetic rodless cylinderCY1SSlide bearing--888
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Variation: D (2-step Control, Single Acting/Bellows Seal, O-ring Seal), Flange Size: 40, Indicator, Actuator Port Direction: w/o Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: 5 to 60°C, w/o Heater, Auto Switch: A93 (A93--Reed, DC Volt, AC Volt, LED, Horizontal), Lead Wire: L (3m), Number of Switches, Mounting Position: A (2 pcs, Valve Open/Closed)