KP Series (with resin thread) 1) Winding of sealant tape Wrap the pipe tape 2 to 3 times around the threads, leaving 1.5 to 2 thread ridges exposed at the end of the threads. 2) Tightening After tightening by hand, tighten an additional 2 to 3 turns using a tightening tool. 2.
The purpose of an air cushion is not to reduce the speed of a piston as it nears the stroke end.
Here is an example showing these relationships.
The date and time of an alarm are displayed if the alarm is touched on the Alarm history screen. A subcode is displayed when an alarm with a subcode is touched twice.
The date and time of an alarm are displayed if the alarm is touched on the Alarm history screen. A subcode is displayed when an alarm with a subcode is touched twice.
Never use in an atmosphere of explosive gases. 6. Do not use in an environment where there is excessive impact shock. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.
Touching an emitter when it is electrified may result in electric shock or other accidents. 4. Do not disassemble or modify this product. Otherwise, an electrical shock, damage and/or a fire may occur.
Never use in an atmosphere of explosive gases. 1. Perform the following maintenance periodically in order to prevent possible danger due to unexpected auto switch malfunction. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 1) Securely tighten switch mounting screws.
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
Never use in an atmosphere of explosive gases. 1. Perform the following maintenance periodically in order to prevent possible danger due to unexpected auto switch malfunction. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2.
It is deduced from the calculation of the pressure changes inside an air tank when discharging the compressed air in a choked flow, from an equipment attached to the air tank.
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.
However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount the switch in a locations where there is no vibration greater than 98 m/s2 or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
Select the proper size of cable according to an actual condition.
IDF-S1966 115 VAC Option symbol R With an earth leakage breaker The air dryer is equipped with an earth leakage breaker, reducing the electrical wiring required during installation.
, making it possible to hold a cylinder intermediate stopping position for an extended time.
Note 2) On the AMC220, an R 1/4 fittinng can be attached by removing the drain cock. (It be comes the drain piping type.
Conforming to ISO 16030-2001, the chamfered dimensions shown in the First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with a wrench. A reference value for the tightening torque is 1 to 1.5 Nm. Note) Excessive tightening may damage the thread portion or deform the gasket and cause air leakage. table below are recommended.