[mm] [mm] Size CRB2 CRBU2 X Y X Y 10 3 to 14 1 to 14 1 to 14 1 to 14 15 4 to 18 1.5 to 18 1.5 to 18 1.5 to 18 20 4.5 to 20 1.5 to 20 1.5 to 20 1.5 to 20 30 5 to 22 2 to 22 2 to 22 2 to 22 40 18 to 30 18 to 30 18 to 30 18 to 30 Size CRB2 CRBU2 X Y X Y 10 3 to 14 1 to 14 1 to 14 1 to 14 15 4 to 18 1.5 to 18 1.5 to 18 1.5 to 18 20 4.5 to 20 1.5 to 20 1.5 to 20 1.5 to 20 30 5 to 22 2 to 22 2
Refer to page 6-12-20 regarding stopping accuracy. 3. In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible.
The load factor for each direction can be obtained as follows. x = 0/400 = 0 y = 50/250 = 0.2 z = 200/1500 = 0.13 5. x + y + z = 0.33 1 2000 1000 2000 800 1500 1500 Lz 600 L1 [mm] L3 [mm] L2 [mm] 1000 1000 400 Ly 500 500 200 Lx 0 0 0 0 10 20 30 40 50 60 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] 44 Model Selection LEF Series Step Motor (Servo/24
Provide an intermediate support for a cylinder with a long stroke. If the cylinder has a long stroke, provide an intermediate support to prevent the rod from sagging and the tube from bending, as well as to prevent damage to the rod due to vibrations or external loads. 16 Series CUJ Actuator Precautions 2 Be sure to read before handling. Mounting Lubrication Caution Caution 1.
With end lock (20) MXS20R With buffer (20) MXS20F 2-M6 X 1 thread 13 deep Operating port 2-Rc(PT)1/8 J 15.5 15 20 58 25 44.5 30.5 0.5 45.5 Dimensions not indicated are the same as basic type.
Furthermore, it cannot be used as an emergency cutoff valve.
For models with an element service indicator, as the element becomes more clogged, the indicator will display an increasing level of red. Be sure to replace the element before the level of red reaches the top of the indicator. Load (F) 30 These safety instructions are intended to prevent hazardous situations and/or equipment damage.
The actuator utilizes an ultra compact design by incorporating the cylintler as paft of the guide boily. As the stroke length increases, so does the hearing length. This enhances the cylinder's load capacity. Conventionally designed guided cylinders have a set beaing length resulling in dramatic decreases in side load capacity as stroke lengths increase.
40 80 70 60 50 40 30 30 20 Point of application L mm 80 60 40 120 100 Point of application L mm 4 Escapements Series MIW/MIS 12, 20 How to Order Finger options Nil: Basic type (Standard type) 1: Tapped on upper and lower faces 2: Tapped on all faces (5 surfaces including end surface) Stroke 12 20 12 20 12mm 20mm MIW only accommodates a stroke of the same length as the cylinder diameter.
Beware that earth leakage from the equipment around the switch such as pump and stray current caused by ground fault should not flow into the fluid to be measured. 1. Take precautions when using the switch for an inter lock circuit.
Since terminal numbers are not indicated on the flat cable, use the triangle mark as a reference for wiring. 1-3-13 14 Series SZ3000 Manifold Electrical Wiring Type 60PG Flat Ribbon Cable Type (20 pins) Without Power Supply Terminal With Power Supply Terminal Positive common Negative common Common 20 20 20 Positive pin (Common) Positive pin 19 19 19 SOL.B 18 18 Negative pin Negative pin
These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion. Pressure Setting 2. Do not use in an environment where a strong magnetic field is present. Caution The influence of the external magnetic filed may cause the switch to malfunction. 1.
These switches are not rated as explosion proof. Never use in the presence of an explosive gas as this may cause a serious explosion. Pressure Setting 2. Do not use in an environment where a strong magnetic field is present. Caution The influence of the external magnetic filed may cause the switch to malfunction. 1.
If the application does not satisfy the safety requirements, add an external circuit for safety reasons as required. 12 - (2) Output Signals Signal Pin No. Name Function Servo alarm output signal ALM+ ALM3 4 Turns OFF when an error is detected. /BK+ (/SO1+) /BK(/SO1) Controls the lock. The lock is released when the signal turns ON.
To operate a relay as a load, use the relay shown in the table below or the equivalent, in order to extend the life of the switch. qWhen handling the product, do not drop an object on it, gouge it, or apply an excessive impact on it. wDo not operate it in an area in which a large amount of magnetism is present.
For details, refer to pages 3-7-19 and 3-7-20.
Accessory None (Standard) With bracket (Except IDG1) Nil B Note) When symbol B is indicated, a bracket assembly with a part number shown in the table below is included as an accessory.
Note 2) Operate an interface regulator only by applying pressure from the P port of the base, except when using it as a reverse pressure valve. When using it as a reverse pressure valve, P port regulation is not allowed to use. Note 3) When using a perfect spacer, assemble a valve, a spacer regulator and a perfect spacer in this order to use it.
Within the reciprocating movement of the actuator, if only the movement in one direction must be controlled, connect an airhydro unit to the cylinder piping port of the control direction as shown in Fig. (1).