SOL.A 3A () (+) Station 3 SOL.B 3B () (+) SOL.A 4A () (+) Station 4 SOL.B 4B () (+) SOL.A 5A () (+) 2.

B 8B () (+) Station 8 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL. A 9A () (+) SOL. B 9B () (+) Station 9 SOL. A 10A () (+) SOL. B 10B () (+) Station 10 Note) When using the negative COM. specification for VQC1000/2000, use valves for negative COM. (+) () COM. Positive COM.

SOL.A 3A SOL.B 3B Station 3 SOL.A 4A SOL.B 4B Station 4 SOL.A 5A 10A COM 10B SOL.B 5B Station 5 SOL.A 6A SOL.B 6B Station 6 SOL.A 7A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B 7B Station 7 Double wiring (connected to SOL. A and SOL.

flange 4B 2B 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 2 3 4 Port size (Nominal size B) 3 4 2 11 2 1 1 1 2 1 1 flange 0.38 0.55 0.9 1.4 2.1 4.2 10.5 50 52 72 87 Weight (kg) JIS Symbol Note) Max. flow is at 0.7 MPa.

Series AFF How to Order Bowl Assembly AFF 4B CA Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Body size Thread type (3) 2B 4B 8B 11B 22B 37B 75B Nil Rc F G N NPT Accessory (Option) A With drain cock (1) Note 3) Corresponds to attachment symbols C, D, and J.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SOL.B 1B () (+) 1 station 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL.A 2A () (+) VQZ SOL.B 2B () (+) 2 stations 1.

with M5 thread Flow direction: Right to left With element service indicator Size 1/8 1/4 3/8 1/2 3/4 1 1 1/2 2 01 02 03 04 06 10 14 20 2B, 150 4B, 250 8B, 350 11B, 450 22B, 550 37B, 650 75B, 850 Rc NPT G 1/8 1/4 3/8 1/2 3/4 1 1 1/2 Nil J M R T Nil B C D Option Accessory Size Bore size RT T R JR JRT MR J MRT JT MT M 03 06 04 01 02 20 14 Size 10 2B, 150 4B, 250 8B, 350 11B, 450 22B, 550 37B

Polarity SOL.A 1A ( ) ( + ) SOL.B 1B ( ) ( + ) 1 station 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL.A 2A ( ) ( + ) SOL.B 2B ( ) ( + ) 2 stations SOL.A 3A ( ) ( + ) SOL.B 3B ( ) ( + ) 3 stations SOL.A 4A ( ) ( + ) SOL.B 4B ( ) ( + ) 4 stations SOL.A 5A ( ) ( + ) 10A COM SOL.B 5B ( ) ( + ) 5 stations

B 8B () (+) Station 8 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL. A 9A () (+) SOL. B 9B () (+) Station 9 SOL. A 10A () (+) Note) There is no polarity. This device can also be used as a negative common. SOL.

Polarity SOL.A 1A ( ) ( + ) SOL.B 1B ( ) ( + ) 1 station 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL.A 2A ( ) ( + ) SOL.B 2B ( ) ( + ) 2 stations SOL.A 3A ( ) ( + ) SOL.B 3B ( ) ( + ) 3 stations SOL.A 4A ( ) ( + ) SOL.B 4B ( ) ( + ) 4 stations SOL.A 5A ( ) ( + ) 10A COM SOL.B 5B ( ) ( + ) 5 stations

A 9A () (+) 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL. B 9B () (+) Station 9 SOL. A 10A () (+) Note) There is no polarity. This device can also be used as a negative common. SOL.

Checker ISA3 Series Dimensions ISA3-mmm-mmmB-L1 (With control unit) L1 (23) 57 30 58.5 41.6 46.2 1.6 3.5 12 11 66 H 5.5 40.4 29 24 16 64.4 (Max. 67.4) 24 3.1 33 52.5 30 Supply port ISA3-C: Rc1/4 ISA3-F: G1/4 1 Detection port ISA3-C: One-touch fitting ISA3-F: G1/8 2 38 13 L2 (49) ISA3-mmm-mmmB-R1m ISA3-mmm-mmmB-R2m 29.3 L1 46.2 41.6 58.5 30 30 52.5 Supply port ISA3-C: Rc1/4 ISA3-F: G1/4 1

Function number Function name Default setting Page F 0 (Unit) Unit selection [ PA] kPa Page 49 ISA3-F: [ 20] ISA3-G: [ 50] ISA3-H: [ 50] Switch point ISA3-F: [ 3] ISA3-G: [ 20] ISA3-H: [ 20] F 1 (oUt1) OUT1 setting Page 50 Hysteresis Display colour [ SoG] Green when ON, Orange when OFF out2: [ Ewin] Output mode OUT port side pressure detection Window comparator mode Reversed output 2ot:

() (0.1 mm0.09 mm0 mm) 1.5 F42.5 GH64 200 kPa 90% -ISA3-F ISA3-G ISA3-H 1 m 1 m 1 m [sec] [sec] [sec] [mm] [mm] [mm] [mm] 3 m 3 m 3 m [sec] [sec] [sec] [mm] [mm] [mm] [mm] 5 m 5 m 5 m [sec] [sec] [sec] [mm] [mm] [mm] [mm] [mm] [mm] -19No.PS-OMT0001CN-E 2 () [()][] 1.5 F42.51 m3 m5 m GH641 m3 m5 m 200 kPa ISA3-F ISA3-G 1 m3 m5 m 1 m3 m5 m [mm] [mm] 9 0 10010 ISA3-H 1 m3 m5 m [mm

-F () () ISA3-G () () ISA3-H ON OFF () () ON() OFF() -44No.PS-OMR0001CN-J 4 (1)(100 kPa200 kPa) (2) () (1) (2) 1 () (3) -45No.PS-OMR0001CN-J 4 2 [F 0] [F] 2 2 [][] 2 F 0(Unit) [ PA] kPa 47 ISA3-F[ 20] ISA3-G[ 50] ISA3-H[ 50] F 1(oUt1) OUT1 48 ISA3-F[ 3] ISA3-G[ 20] ISA3-H[ 20] [ SoG] ON OFF F 2(oUt2) () [ ---] 50 F 6( FSt) [ 0.0] 0.0 51 F10( SUb) [ LEvEL] 52

COM (+) () (+) () SOL.A 1A Station 1 (+) () SOL.B 1B (+) () SOL.A 2A Station 2 (+) () SOL.B 2B (+) () SOL.A 3A Station 3 (+) () SOL.B 3B (+) () SOL.A 4A M2.5 Station 4 (+) () SOL.B 4B (+) () SOL.A 5A Cover 1st row 3rd row 2nd row -Step 2. Wiring The diagram on the left shows the terminal block wiring schematic. All stations are provided with double solenoid wiring.

Station 4 SOL.B 4B SZ Cover SOL.A 5A Station 5 SOL.B 5B SOL.A VF 6A Station 6 SOL.B 6B SOL.A 7A VP4 Station 7 SOL.B 7B SOL.A As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station for 10 stations or less, regardless of valve and option types.

IDF1E 0.75 Rc3/8 IDF2E 1.5 IDF3E 2.2 IDF4E 3.7 Rc1/2 IDF6E 5.5 Rc3/4 IDF8E 7.5 IDF11E 11 IDF15E1 15 Rc1 IDF22E 22 R1 IDF37E 37 R1 1/2 IDF55E 40C 0.7 MPa 55 R2 IDF75E 75 35C 0.7 MPa Model Rated inlet condition Applicable air compressor [kW] Port size IDF100F 100 R2 IDF125F 125 65 (2 1/2B) Flange IDF150F 150 80 (3B) Flange IDF190D 190 IDF240D 240 100 (4B) Flange IDFlE 40C 0.7 MPa IDF370D 35C

COM (+) () (+) () SOL.A 1A Station 1 (+) () SOL.B 1B (+) () SOL.A 2A Station 2 (+) () SOL.B 2B (+) () SOL.A 3A Station 3 (+) () SOL.B 3B (+) () SOL.A 4A M2.5 Station 4 (+) () SOL.B 4B (+) () SOL.A 5A Cover 1st row 3rd row 2nd row -Step 2. Wiring The diagram on the left shows the terminal block wiring schematic. All stations are provided with double solenoid wiring.