One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.
= Inlet pressure) (P2 = Outlet pressure) Inlet pressure P1 (MPa) R A Flow rate (/min (ANR)) P A Inlet pressure: 0.3 MPa Outlet pressure (MPa) Set point Set point Outlet pressure (MPa) Inlet pressure P1 (MPa) Outlet pressure (MPa) Set point Set point R A Flow rate (/min (ANR)) P A Inlet pressure P1 (MPa) 14-9-14 5 Electro-pneumatic Proportional Valve Series VEF/VEP Construction Flow type
When the work piece comes close to the detection nozzle, the back pressure P2 increases until it is larger than P1 (P2 > P1). Then the switch output turns on to notify that the pressure is below the detection gap.
OFF OFF OFF OFF P1 n1 P2 P1 n2 n1 (Standard: Factory setting) (Reversed) (Standard: Factory setting) (Reversed) Press the SET button to set the mode and proceed to the output type setting. 16-2-6 7 Series ZSE30/ISE30 High Precision, 2-color Display Digital Pressure Switch Pressure setting Auto preset setting Manual setting Press the SET button in the measuring mode to display the set value
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area [mm] P: Pressure drop rate (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
Port size Enclosure C4 C6 C8 C0 F0 F1 F2 F3 P1 P2 P3 L0 L1 L2 T1 T3 M1 M2 M3 Nil W Dust-protected Dust-tight, Water-jet-proof (IP65) With 4 One-touch fitting With 6 One-touch fitting With 8 One-touch fitting Without One-touch fitting (With clip) Without lead wire F kit for 2 to 12 stations/Double wiring F kit for 13 to 24 stations/Double wiring F kit for 2 to 24 stations/Single wiring P/J
P1 12 C L4 M2 9.7 2 The release button of 6 One-touch fitting is oval as shown above. The button can be rotated freely. L1 L21 L3 M1 d2 M3 Q1 D22 2 x F VAC.
Nil Without restrictor With restrictor S Digital flow switch ON/OFF valve Nil Without digital flow switch NPN open collector 1 output + Analog output (1 to 5 V) PNP open collector 1 output + Analog output (1 to 5 V) NPN open collector 2 outputs PNP open collector 2 outputs NPN open collector 1 output + Analog output (4 to 20 mA) PNP open collector 1 output + Analog output (4 to 20 mA) P1
Port size Enclosure C4 C6 C8 C0 F0 F1 F2 F3 P1 P2 P3 L0 L1 L2 T1 T3 M1 M2 M3 Nil W Dust-protected Dust-tight, Water-jet-proof (IP65) With 4 One-touch fitting With 6 One-touch fitting With 8 One-touch fitting Without One-touch fitting (With clip) Without lead wire F kit for 2 to 12 stations/Double wiring F kit for 13 to 24 stations/Double wiring F kit for 2 to 24 stations/Single wiring P/J
Flow characteristics: C Max. operating frequency To CYL port SUP side pressure (P1) Note) Based on JIS B 8375-1981 (Supply pressure: 0.5 MPa) Dimensions Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Single unit Manifold 21.5 (5) 18 29 10.5 2n-C4, C6 C4: One-touch
O F , < F , Q r '=r, @ r,> r, Pressure Raies (P1 =Primary Pressure) (P2=Secondary Pressure) NVEP3l2O-2 NVEP314O-'r -04 Primary Pressure P1 = 45 PSIG (3 KSI/cmr) E t2 I { t r S F g t o o E 28 (r. a ( 1 ) E a E a NVEHtl4O-1 E t ^ *t 6 S (0.15) (0.s) t . 5 ( 0 1 ) F 5 (0.05) NVEE NVEP CONSTRUCTION DETAIL Flow Raie'lvpo: VEF212O (2 Pdts) NVEF:112O (3 Porb) Pressuro llrp: NVEP3I2O (3 Porb) l
How to Calculate Flow (At an air temperature 20C) 1P1+0.1013<1.89(P2+0.1013) Q=226S P(P2+0.1013) Piping 2P1+0.10131.89(P2+0.1013) 1Completely flush (air blow) pipes before plumbing to remove dust. 2Clamping torgue: Q=113S(P1+0.1013) Q:Flow rate under standard conditions [ /min (ANR)] P1:Upstream pressure (MPa) P2:Downstream pressure(MPa) P:Pressure differential(P1-P2)(MPa) S:Effective area
(P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor Q P P1 P2 S Cv 9
Normal primary pressure Drop of primary pressure Increase of primary pressure Pressure P1 P2 Time Switch output 1, 2 ON OFF The correction value is not stored on the EEPROM. When auto shift is used: When the primary pressure changes, set the auto shift function to Lo.
The pressure set by a compact regulator valve or an electro-pneumatic regulator is supplied to the P1 (external pilot) port of the VEX, which controls the large amount of pressure.
When the pressure is released to P1 (external pilot), the A (output) port side air is exhausted from the R (exhaust) port.
Fixed orifice and variable throttle are available as a throttle for adjusting the pressure increase. (1, 1.5, 2) Output Pressure (P2) vs Time Graph Output P2 P1 P2 reaches half of P1, and then the main valve of the soft start-up valve turns on.
P1 Parts assembly Parts assembly Degrease/Wash Degrease/Wash P2 P2 Pure water (16M-cm) wash Assembly Time Time Assembly Inspection Circuit diagram Inspection Interior purge P2 P1 2 1 2 1 Interior purge Package SRH Clean booth Class 100 Package 856 Clean Regulator SRH Series ARJ How to Order AR425 to 935 ARX 02 SRH 3 0 0 0 AMR Gauge port orientation ARM Body size 3 4 1/4 3/8 Nil: Standard
Normal primary pressure Drop of primary pressure Increase of primary pressure Pressure P1 P2 Time Switch output 1, 2 ON OFF The correction value is not stored on the EEPROM. When auto shift is used: When the primary pressure changes, set the auto shift function to Lo.
Normal primary pressure Drop of primary pressure Increase of primary pressure Pressure P1 P2 Time Switch output 1, 2 ON OFF Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com The correction value is not stored on the EEPROM.