W: 800 [W] w Derive the heat generation amount from the power supply output.
Auto switch rails on both side faces (with 2 pcs.) 1500 Made to Order Specifications Click here for details 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 40 1500 Symbol Specifications -XB9 -XB13 -XB22 Low speed cylinder (15 to 50 mm/s) Note) Intermediate stroke is available in 1 mm increments.
VS4040-S-03 VS4040-S-04 DXT131-15P-06 DXT131-15P-10 DXT132-15-2P-12 DXT132-15-2P-14 XT021-9 DXT132-16 M6 x 25 with washer M8 x 35 3 8 1 2 3 4 VP450 Aluminum alloy Sub-plate !0 1 1 VP470 1 1 4 1 2 VP450 VP470 VP450 VP470 in part numbers are the same symbol for the thread type in How to Order. Gasket !1 Hexagon socket head screw VT3112-00G !2 Thread for mounting valve.
Stainless Steel Cylinder Se ries CG5-S 20, 25, 32, 40, 50, 63, 80, 100 How to Order X165US TN CG5 L N 25 S R 100 Without Auto Switch X165US TN CDG5 L N 25 S 100 G5BAL R With Auto Switch Inch rod thread (Only available with "TN" port option. Currently only available on the 20 to 63mm bore sizes.)
Example using a 20[mm] Lead Actuator with target travel speed of 500[mm/sec] Rotations per second Travel distance per second Travel distance per rotation Rotation Speed (rpm) = {Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) The rotation speed must be a value between 0 and the allowable actuator speed. The actuator will not operate if set to 0.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com V (mm/s) = Auto switch operating range (mm) Load operating time (ms) x 1000 Current to operate load (OFF condition) > Leakage current If the condition given in the above formula is not met, it will not reset correctly
mm 176 mm HECR012-W2 HRCR010-A2 Air-cooled Air-cooled Water-cooled 200 W, 400 W, 510 W 800 W, 1 kW 800 W, 1.2 kW Mountable in a 19-inch rack Space can be saved by mounting multiple pieces of equipment together in a single rack.
R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) The combination of K, L and M is not possible because an auto drain can only be attached to a single option. *2 The maximum operating pressure is 1.6 MPa. *3 Voltage symbol 20 (200 VAC) is the terminal block connection as standard. The Option S cannot be chosen.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
01(R) Note 1) Option Note 2) When two or more symbols are specified, indicate them alphabetically. (2) 01 [Rc 1/8] 02 [Rc 1/4] 02 [Rc 1/4] 03 [Rc 3/8] VQZ200 VQZ200-S(2) VQZ300 VQZ300-S(2) Note) Symbol R indicates an external pilot.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.03 s or less 0.03 s or less 0.05 s or less 0.05 s or less Response time Hysteresis 3% F .S. IR Repeatability 3% F .S. VEX Sensitivity 0.5% F .S.
OUT Standard specification Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x101 Pa) (V, M) Non-leak (106 Pa m3/s or less) (V, M) IN N.O.
Valve model Type of actuation Port size 1 4/2 (P A/B) Flow characteristics Note 2) Note 3) Effective area mm2 4/2 5/3 (A/B EA/EB) Weight (g) Pilot port size Cv C [dm3/ (s bar)] b Cv C [dm3/ (s bar)] b Grommet Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center 48
Rc NPT G Function 0 1 2 3 position closed center 3 position exhaust center 2 position Flow Characteristics VH200 VH300 VH400 Effective area S = 55 mm2 Effective area S = 7.5 mm2 Effective area S = 20 mm2 Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa Supply pressure MPa 1.0 1.0 1.0 1.0 1.0 1.0 Valve
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Functions Error function Display calibration function Take the following corrective solutions when error occurs.
and up: Stroke length tolerance Standard Stroke Table Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Symbol 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350
TEST DATA MONITOR No.0 1 No. 0 50.00mm 250mm/s ALARM JOG SETTING DATA SET 40 SET 1 No. 0 40.00mm 100mm/s 250100mm/s 1 No. 0 40.00mm 250mm/s MENU 100 SET TEST DATA MONITOR No.0 1 No. 0 40.00mm 250mm/s No.1 1 No. 0 40.00mm 250mm/s ALARM JOG SETTING No.
None With light/Surge voltage suppressor (Except type G) With surge voltage suppressor (Type G only) VX2 Option Option S VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Accessory Function plate (D seal, with thread): DXT060-32-4A Electrical entry G E T D VX3
4/RJ08 4 4 12 10 Impact mass m [kg] Impact mass m [kg] Impact mass m [kg] RJ1007L 3 3 8 RJ0806L RJ0604 2 6 2 4 RJ0806H RJ1007H 1 1 RJ0805 RJ1006 2 0 0 0 0 500 1000 1500 2000 0 500 1000 1500 2000 0 200 400 600 800 1000 Collision speed [mm/s] Collision speed [mm/s] Collision speed [mm/s] Graph !6/RJ14 Graph !8/RJ27 Graph !