Plate cylinder with lock series MLU is ideal for maintaining supply pressure to prevent dropping of the load when residual pressure is released. Drop prevention is possible at any point of stroke. Lock positions can be changed to accommodate the position of the external stopper and the thickness of the clamped work piece. Release-plate cylinder with lock, Bore sizes: 25, 32, 40, 50, Slim
For the standard CQS series long stroke type cylinder, the symbol “C” (with rubber bumper) is required in the part number.
Similarly, it is also required for CQS*S series cylinders (anti-lateral load type).
However, the rubber bumper (option “C”) cannot be selected for CQSK series cylinder (non-rotating rod type).
Rated Pressure Range: -0.1 to 1 MPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Piping: ø1/4" One-touch Fitting, Elbow Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Piping: ø6 One-touch Fitting, Elbow Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Piping: ø1/4" One-touch Fitting, Staight Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: URJ1/4, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: URJ1/4, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Model: -100 to 100kPa, Piping: ø1/4" One-touch Fitting, Elbow Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Model: 0 to -101kPa, Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Model: 0 to -101kPa, Piping: R 1/8, w/M5 Female, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Model: 0 to -101kPa, Piping: ø4, ø5/32" One-touch Fitting, Elbow Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Model: 0 to -101kPa, Piping: ø1/4" One-touch Fitting, Elbow Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Model: -100 to 100kPa, Piping: ø4, ø5/32" One-touch Fitting, Straight Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -
Model: -100 to 100kPa, Piping: ø4, ø5/32" One-touch Fitting, Elbow Type, Output: PNP Open Collector 2 Outputs, Display Unit: w/Unit Display Switching Function, Lead Wire: None, Bracket/Panel Mount Adapter: Panel Mount Adapter, Operating Manual/Certificate: -, Made to Order: -