, D-C8 D-H7, D-H7W, D-H7F, D-H7BAL Auto switch 8.5 Approx.
D-X g Weight mm Height Model mm Width Auto switch mounting 20Three types of auto switches can be mounted.
Initial value Recommended value No Servomotor Rotation Direction can Pn000 0 0001 (+Counter motors side ) Tuning-less Function Related Switch Pn170 1401 1401 Electronic Gear Ratio (Numerator) *3 Pn20E 4 65536 Electronic Gear Ratio (Denominator) *3 Pn210 1 1250 750 375 1500 1000 500 1875 1250 625 LEFS25(L,R) LEFS32(L,R) LEFS40(L,R) Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8
Range (mm) No. of auto switches mounted Applicable auto switch Bore size (mm) 25 6 4 D-M5, D-M5W, D-M5T D-E7A, D-E80A Auto switch model 40 6 4 D-M5, M5W, M5T D-E7A, E80A 32 6 4 10 15 5 10 1 pc. 2 pcs.
,B6 D-C7,C8 D-C73C D-C80C D-G5 D-K5 D-G5NTL D-H7W D-H7F D-H7BAL D-B59W D-H7 D-H7C D-C73C D-C80C D-G5W, K59W D-G59F D-G5BAL Bore B 16 (24) 16 (24) 17 (25) 19.5 (28.5) 24 (36) 24 (36) 32.5 (46.5) 32.5 (46.5) B 20.5 (28. 5) 20.5 (28.5) 21.5 (29.5) 24 (33) 28.5 (40.5) 28.5 (40.5) B 17.5 (25.5) 17.5 (25.5) 18.5 (26.5) 21 (30) 25.5 (37.5) 25.5 (37.5) 34 (48) 34 (48) B 18 (26) 18 (26) 19 (27) 21.5
D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V 20 to 63 B A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5
Minimum Stroke For Auto Switch Mounting (mm) D-A7 D-A80 D-A73C D-A80C D-A9V D-A7H D-A80H D-F7 D-J79 D-F9W D-F7W D-J79W D-F7BAL D-F79F D-F9BAL D-F7WV D-F9WV D-F7BAVL D-F7V D-J79C D-M9V No. of auto switches mounted D-A9 D-M9 D-A79W 1 pc. 2 pcs. 5 5 5 10 10 15 15 15 15 20 20 20 10 10 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
For notes e and r, refer to the left. 4B/6B 870 M20 X l 500 AMF1000 e Even if its deodorization performance has not decreased, the replacement interval for the element is when the pressure drop reaches 0.1MPa or after 2 years of operation, whichever comes first. r When the element has reached its replacement interval, replace it immediately with a new element.
Port size 10 8 6 12 1/8" 1/4" 3/8" 5/32" 3/16" 5/16" 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 x 0.8 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32 UNF NPT 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure
D D Note) Be sure to use a flat washer for the A type mounting. b) B type mounting (when using the cylinder tube threads) E t E t Compatible mounting bolt dimensions Model A type mounting B type mounting C (mm) D: Bolt length (mm) Mounting bolt size E (mm) Mounting bolt size MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB28-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB28-D M4 x 0.7 35 + Stroke
] 500 L/min (PFMB7102) The accumulated flow has exceeded the accumulated flow range.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-14 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.
U S C E Padlock mounting position D C Padlock mounting position D SUP. SUP A B A B IN OUT IN OUT 2 1 3 EXH. EXH.
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: Without auto switch,