Single rod CQ2 7-6-108 10 to 300 Double acting 125, 140 160, 180 200 Double rod CQ2W 7-6-115 10 to 300 Long Stroke 32, 40, 50 63, 80, 100 Single rod CQ2 Double acting 7-6-121 125 to 300 Anti-lateral Load Single rod CQ2S 32, 40, 50 63, 80, 100 Double acting 32 to 40/5 to 100 50 to 100/10 to 100 7-6-132 With End Lock 20, 25, 32 50, 63, 80 100 Single rod CBQ2 Double acting 20 to 63/10 to 100
Rated voltage For DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted type Electrical entry 24 VDC, 12 VDC, 6 VDC, 5 VDC, 3 VDC Grommet L plug connector M plug connector G: 300 mm lead wire L: 300 mm lead wire M: 300 mm lead wire MN: Without lead wire Light/Surge voltage suppressor Nil S Z R U Without light/surge voltage suppressor With surge voltage suppressor With light/surge
Recommended shim thickness) Arm length L: 6 in 0.04 0.02 0.06 500 Clamping force (lbf) 400 0.7 MPa 300 0.5 MPa 0.3 MPa 200 100 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Shim thickness (in) 186 Model Selection 2 Slim-line power clamp cylinder mounting 63 Arm length L: 200 mm 4000 Clamping force (N) 3000 CK1 CLK2 C(L)KQ MK2T/MK2/MK CKZ2N CKZT CLKZ1R CK/M(D)UKA 2000 1000 0 0 1 2 3 4 5 6 7 8 9 Shim
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
Selection Graph (1) Selection Graph of Pad Diameter by Lift Force Horizontal (Reference value) 125 -40kPa -45kPa -50kPa -55kPa -60kPa -65kPa -70kPa -75kPa -80kPa -85kPa 100 Pad diameter (mm) 80 63 50 40 10 30 50 70 100 200 300 Lifting force (N) Selection Graph (2) Selection Graph of Pad Diameter by Lift Force Vertical (Reference value) 125 -40kPa -45kPa -50kPa -55kPa -60kPa -65kPa -70kPa
Remote Type Water resistant construction conforming to IP65 Series PF2A Series PF2A For Air Flow rate measurement range (l /min) For Air For Water For High Temperature Fluid (Water 90C) 0.5 to 4 2 to 16 5 to 40 0.5 to 4 2 to 16 5 to 40 10 to 100 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 600 to 12000 Integrated Type Series PF2W Series PF2W For Water Application
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
250, 300, 350, 400 MGCM Slide bearing Data 350, 400, 450, 500 350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 40 200, 250, 300 Ball bushing bearing 700, 800 MGCL 350, 400, 450, 500, 600, 50 700, 800, 900, 1000 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
300 400 Outlet air flow rate (L/min (ANR)) 0 200 400 600 800 1000 1200 Outlet air flow rate (L/min (ANR)) 0 500 1000 1500 2000 Outlet air flow rate (L/min (ANR)) Pressure Characteristics Pressure Characteristics Pressure Characteristics Inlet pressure: 0.7 MPa Outlet pressure: 1.0 MPa Flow rate: 20 L/min (ANR) Inlet pressure: 0.7 MPa Outlet pressure: 1.0 MPa Flow rate: 20 L/min (ANR) Inlet
300 300 200 200 Lower limit 100 100 Lower limit 0 0 10 20 30 40 0 10 20 30 40 0 Transfer speed [m/min] Transfer speed [m/min] RS2H63-30 The graphs indicate the values at normal temperature. (20 to 25C) = 0.2 = 0.1 1,000 900 800 700 600 500 400 300 200 100 0 1,000 900 800 700 600 500 400 300 200 100 0 Mass of transferred object m [kg] Mass of transferred object m [kg] 63 Operating range
, 250, 300 71.5 177 27 16 52 57 M14 x 1.5 5 14 136 24 100, 125, 150, 175, 200, 250, 300, 400, 500 85.5 200, 300, 500 193 32 20 64 71 M18 x 1.5 7 18 144 22.5 98.5 200, 300, 500 194 32 20 77 84 M18 x 1.5 7 18 145 21 P M N O T X Z L Q Bore size (mm) 32 40 50 63 41 34 5.5 M6 x 1 Rc(PT) 1/8 57.5 30 14 56 41 40 5.5 M6 x 1 Rc(PT) 1/8 64.5 30 14 62 49 50 6.6 M8 x 1.25 Rc(PT) 1/4 76.5 35 19 61.5
, 250, 300 100, 125, 150, 175, 200, 250, 300, 400, 500 32 131 90 27 16 45 49.5 64 M14 X 1.5 14 4.5 14 40 177 136 27 16 52 57 71.5 M14 X 1.5 24 5 14 50 63 200, 300, 500 193 144 32 20 64 71 85.5 M18 X 1.5 22.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 X 1.5 21 7 18 P T* X M N O Q Z L Bore size (mm) 32 40 50 63 Rc(PT) 1/8 57.5 41 34 5.5 M6 X 1 56 30 14 Rc(PT) 1/8 64.5 41 40 5.5 M6 X 1
Tube bore size B, #2(#2+#3) 40 125, 150, 175, 200, 250, 300 55 14 14 3.8-9 Series CXT Auto Switch Specifications Refer to p.5.3-2 for details on auto switch.
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
LAT3LAT3MLAT3F600 350 700 Min. travel time [ms] Min. travel time [ms] Min. travel time [ms] Load weight1000g Load weight1000g Load weight1000g 300 600 [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g 50 100 100g 0g 0g 0g 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 0 10 20 30 40 50 Total travel distance [mm] Total travel
Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 100 Up to 300 Up to 400 More than 400 Up to 100 Up to 300 Up to 400 More than 400 Up to 100 Up to 300 Up to 400 More than 400 Up to 100 Up to 300 Up to 400 More than 400 Up to 100 Up to 300 Up to 400 More than 400 Max. speed (mm/s) 6 (7) (8) (9) 10 15 Selection graph 20 (10) (11) (12) (13) (14) (15) (17) (16) 25 32 The maximum