Mounting: Foot, Bore Size: 40mm, Thread: Rc, Full Stroke: 200mm, First Stroke: 50mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Mounting: L (Foot), Bore Size: 40mm, Thread: Rc, Full Stroke: 300mm, First Stroke: 200mm
Supply pressure: 0.3 to 1.0 MPa Set pressure: 0.2 MPa Flow rate: 0 L/min (ANR) Supply pressure: 0.5 MPa IR1000-01 IR1000-01 IR1000-01 Back pressure: 0.5 MPa 0.5 0.204 0.2 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) Set pressure (MPa) 0.4 0.202 0.15 Set point 0.3 0.200 0.1 0.2 0.198 0.05 0.1 0.196 0 40 20 80 60 100 140 120 0 50 100 200 250 150 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8
Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p
Refer to p.0-39 through 0-46 for Safety Instructions and common precautions. 0.3 0.5 0.7 90 IN 27 45 63 5.2 12 CU 113 OUT 34 57 79 168 IN 50 84 117 6.2 16 CQS 201 OUT 60 101 141 Snap Ring Installation/Removal Caution 256 IN 77 128 179 CQ2 8.2 20 314 OUT 94 157 220 401 IN 120 200 281 MU 10.2 25 q For installation and removal, use an appropriate pair of pliers (tool for installing a C type
g 2 m: Approx. 200 g 3 m: Approx. 280 g 5 m: Approx. 440 g 10 m: Approx. 840 g 0.5 m: Approx. 80 g 1 m: Approx. 120 g 2 m: Approx. 205 g 3 m: Approx. 285 g 5 m: Approx. 450 g 10 m: Approx. 865 g Weight *1 Can also be connected to an M12 5-pin socket A-coded connector 223-1 A Communication Cable/Connector M12 Example of Connection PLC EX260 EX123/124/126 EX500 EX600 EX245 EX250 EX120/121/
MK-F020 MK-F025 MK-F032 MK-F040 MK-F050 MK-F063 Bore size (mm) 20 25 32 40 50 63 Accessory With boss in head side 2 3 5 7 13 25 With arm 100 100 200 200 350 350 13 32 Centering location ring Set pin Bolt for cylinder body Rear flange type (including mounting bolt) 133 153 166 198 345 531 Calculation: (Example) MKG20-10RFN Standard calculation: MKB20-10R 250 g 6 g 133 g 2 g 100 g 491
10 10 10 MGF40 Data MGF40 10 5 4 3 5 4 3 2 2 5 5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 200 mm l = 300 mm Graph (3) Graph (4) v = 150 mm/s or less v = 200 mm/s or less Graph (7) Graph (8) 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 MGF100 10 MGF100 MGF100
Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM30-A AFD30-A P1=0.5 MPa 0.04 P1=0.7 MPa P1=0.3 MPa 0.04 P1=0.5 MPa P1=0.3 MPa 0.03 Pressure drop [MPa] Pressure drop [MPa] P1=0.7 MPa 0.03 0.02 0.02 P1=0.5 MPa P1=0.3 MPa P1=0.5 MPa P1=0.3 MPa 0.01 0.01 P1=0.7 MPa P1=0.7 MPa 0 0 0 0 50 100 150 200 100 200 300 500 400 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM40-A AFD40-A P1=
, 300 (N) 100, 200, 300, 400, 500 15 750 1 axis Operating pressure (MPa) Piston area (mm2) 100, 200, 300, 400, 500, 600 20 Bore size (mm) 1000 0.3 0.2 0.4 0.5 0.6 0.7 100, 200, 300, 400, 500, 600, 800 25 1200 10 15 23 78 31 39 54 46 100, 200, 300, 400, 500, 600, 800, 1000 25 2 axis 15 35 52 176 70 88 123 105 1500 32 20 62 94 314 125 157 219 188 Note) Strokes are manufacturable in 1 mm increments
MU Theoretical Output (N) OUT IN DOperating pressure (MPa) Rod width across flats (mm) Piston area (mm2) Bore size (mm) Action 0.3 0.5 0.7 -X 90 IN 27 45 63 12 5.2 20113 OUT 34 57 79 168 IN 50 84 117 16 6.2 Data 201 OUT 60 101 141 256 IN Allowable Kinetic Energy (J) 77 128 179 20 8.2 314 OUT 94 157 220 Bore size (mm) 12 16 20 25 401 IN 120 200 281 Allowable kinetic energy 0.022 0.038 0.055
Stations L1 L2 3 74 56 6 122 104 8 154 136 10 186 168 20 346 328 2 58 40 4 90 72 5 106 88 7 138 120 9 170 152 11 202 184 12 218 200 13 234 216 14 250 232 15 266 248 16 282 264 17 298 280 18 314 296 19 330 312 1.2-45 Series SYJ5000 40 Type Manifold: Bottom Ported/SS5YJ5-40Station -M5 Grommet (G), (H) (Lead wire length) G: 300 H: 600 4-4.5 (Mounting holes) 13 (Pitch) P=16 21 103.2 (GZ, GS
Station 2 58 40 Station 20 346 328 Station n L1 L2 3 74 56 4 90 72 5 106 88 6 122 104 7 138 120 8 154 136 9 170 152 10 186 168 11 202 184 12 218 200 13 234 216 14 250 232 15 266 248 16 282 264 17 298 280 18 314 296 19 330 312 39 Series SYJ5000 [ ]: AC Type 40: Bottom Ported/SS5YJ5-40Stations -M5 Grommet (G) Approx. 300 (Lead wire length) 9 L2 L1 4-4.5 (For mounting) 13 36.9 (DIN 38.1) 21.5
Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.
Cylinder Speed Chart Bore size Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 500 400 300 200 100 0 A 800 900 1000 700 600 500 400 300 200 100 0 B 900 1000 800 700 600 500 400 300 200 100 0 C 800 900 1000 700 600 500 400 300 200 100 0 D 800
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 25 32 40 2000 2000 2000 *When the required stroke is longer than the standard stroke , refer to the specifications for Made to Order q (p.5.4-79) longer stroke styles.
S070 Nil Standard (Internal pilot) R External pilot Manual override VQ Option Light/Surge voltage suppressor Nil Push type Rated voltage B Locking type (Slotted) Nil None VKF 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz C Locking type (Manual) With light/surge voltage suppressor (Type E, T, D, or Y only) Z Option VQZ 110 to 120 VAC, 50/60 Hz S With surge voltage suppressor (Type G only) 4