No. 1 LED 2 3 4 (BUS OUT) 5 6 (PCI) 7 8 9 10 () 11 (BUS IN) 12 (2 ) (BUS OUTPCI) -18No.EX-OMN0029CN-D BUS IN BUS OUT 1 DRAIN 2 V+ 3 V4 CAN_H 5 CAN_L BUS OUT BUS OUT DeviceNetDeviceNet (BUS IN ) T SI IP67 DeviceNet -19No.EX-OMN0029CN-D (1) (2) (3) (4) (0.30.4 Nm) OFF OFF 0 -20No.EX-OMN0029CN-D Address/Data Rate DeviceNetData Rate Address (X10) DeviceNet Address (X1
(Default setting) 8 7 Configuration Mode Address X1 9 6 x10 x1 2 1 0 0 5 Mark C on the unit Mark B at cable end Mark A at cable end 4 Address 1 9 4 3 1 0 : : (1) 2 3 Input data + System diagnosis + Unit diagnosis (Up to 10 units) Input data + System diagnosis Input data only (Default setting) 8 7 9 6 6 Content 3 4 1 2 0 5 Content 5 0 (Default setting) 4 1 2 3 Node Address Data Rate 8 7 PGM
7 8 9 10 11 (BUS IN) 12 (2 ) (BUS OUTPCI) -16No.EX-OMN0027CN-D BUS IN BUS OUT 1 NC 2 RXD/TXD-N 3 NC 4 RXD/TXD-P 5 Shield T PROFIBUS DP BUS OUT SI IP67 PROFIBUS DP A [kbps] 9.6 19.2 45.45 93.75 187.5 500 1,500 3,000 6,000 12,000 [m] 1,200 1,000 400 200 100 -17No.EX-OMN0027CN-D (1) (2) (3) (4) (0.30.4Nm) OFF OFF 0, -18No.EX-OMN0027CN-D PROFIBUS DP (X10)PROFIBUS DP (X1
Red LERR LED is flashing 1 3 4 1 2 Content Err (Default setting) 5 2.5 Mbps 625 kbps Content 5 Mbps CC-Link version Node number 2.00 2.00 2.00 2.00 1.10 1.10 1.10 1.10 64 1 : 8 7 9 6 Number of occupied nodes x10 x1 0 5 4 4 Pin number 1 Address 2 3 5 3 1 4 2 3 2 1 1 4 3 2 1 (2) (3) Content 8 7 9 6 6 Number of occupied nodes SI unit output data size 4 byte (Default setting) 0 5 4 1 2 3 Signal
Extended cyclic occupied units RX/RY stations 1 15 1.10 x1 2 64/64 8/8 2 15 1.10 x1 4 128/128 16/16 3 15 2.00 x8 2 384/384 64/64 4 15 2.00 x8 4 896/896 128/128 5 31 2.00 x8 2 384/384 64/64 6 31 2.00 x8 4 896/896 128/128 7 63 2.00 x8 4 896/896 128/128 8 127 2.00 x8 4 896/896 128/128 * The last register of the bit area (16 bits) cannot be used as it is allocated for the system area.
X1 0.2 MPa, 0.4 MPa and 0.8 MPa settings can be combined. Set pressure Accessory (Pressure gauge) G33--01 (IR1000), G43--01 (IR2000) Non-grease specifications Note 1) Regulators to be manifolded are counted starting from stations 1 on the left side with the OUT ports in front.
Type of seal Special Options R Rubber S Metal Standard X1 External Pilot Supply Size 6 Size 1 8 Size 2 10 Size 3 Pilot Exhaust Options Pilot Exh. through footprint V1 External Individual Pilot Exhaust Configuration FG 2-position Number of Solenoid Subplate (NPTF) FHG 3-position, Closed center FJG 3-position, Exhaust center Without Subplate A02T Side 1/4 For VSR/S8-6 S Single D Double FIG
UTC SPECIAL DESIGN. 1"x1"x1" NPT PVC Tee Fitting. 0.22600 lb. H41.
Nil S R V RV VP B BS BR Side Top Bottom A-e aTension bolt ( ) For silencer (supply side). E port is plugged. Note) B for bottom ported can be selected for the SY5000/7000 series. Tightening torque: 0.8 Nm SY3000: 2 pcs. SY5000/7000: 3 pcs.
BS* X X X BT* X X X X B* X X X X X *End lock and shock absorber options are not available for MXS6 Note 1) When buffer is used in conjunction with extension stroke adjust, stroke adjustment will limit stroke of buffer. Applicable auto switch lead wire length(m) Load voltage Auto switch part No.
Bore L 6 8 12 16 20 25 6 8 12 16 20 25 3.11-24 Air Slide Table Series MXS Option Specifications Dimensions of Adjuster Option/With Shock Absorber (BS, BT) Extension End Mounted to body Mounted to table D M Q A P J CL H K MLGC B CNA G G E E1 F C CB MXS-BS20 MXS-BS25 MXS-BS 8 MXS-BS12 MXS-BS16 L CV/MVG CXW Mounted to body Mounted to table Adjuster Part No.
V0V CANL FG CANH V+ 24V V0V CANL FG CANH V+ BDH BS+ BDL BS24V 0V BDH BS+ BDL BS24V 0V 24V Master unit SI unit SI unit DG DB DA DG DB DA DG DB DA End resistance End resistance Master Connector with end resistance VSLD FG FG FG BDH CANL BDL FG CANH Type 3 grounding Type 3 grounding Type 3 grounding V+ Branching crimp connectors Twisted pair line with shielding DeviceNet CompoBus/S System
BS + Stroke (mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 B1 17 19 22 27 27 C 54 68 86 104 124 B 24 28 32 39 50 BY 7 8 9 9 12 AL 19.5 23.5 27 32 32 BX 9 6.5 8 10 11 ET A 22 26 30 35 35 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 BT Model MUWB25 MUWB32 MUWB40 MUWB50 MUWB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5
BS + Stroke (mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 B1 17 19 22 27 27 C 54 68 86 104 124 B 24 28 32 39 50 BY 7 8 9 9 12 AL 19.5 23.5 27 32 32 BX 9 6.5 8 10 11 ET A 22 26 30 35 35 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 BT Model MUWB25 MUWB32 MUWB40 MUWB50 MUWB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5
BS Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.
Nil B BS With shock absorber (1pc. on port side) The adjustment bolt is installed even when B or BS is selected. (except for 10) Refer to "Auto Switch Guide" (E274-A) for further details on auto switch units. Refer to pages 60 and 61 for auto switch circuit diagrams. Applicable auto switch types Lead wire length (m) Note 1) Load voltage Electrical entry direction Auto switch no.
ends) Note: Minimum impact velocity tor PM nlodels it 4 itr/*c. 9k**k &"bs*rbers Non-Adjustable Hydraulic Series 49rc.
May bs hld enrgiz6d indetlnliely wlthoul damage. However, care muet bs laken to arange your controls so that you nevr energlz both solenolds simultanously. lf bolh solenoids are enrglzd, solenold wlll burn out. Heavy duty alr valves bullt to comply with JIC and all industrial slandards.
With shock absorber (1 pc. on port side) TN TF 20, 25, 32 BS The adjusting bolt is installed even when B or BS is selected.(Except 10) Standard stroke (mm) Refer to Standard Stroke on page 1529.
JOG operation mode HOLD /BS UP L R MON Monitors operating condition. Monitor mode DOWN MODE ENT /ESC Directs alarm code display and clear. ALM Alarm reset mode For the operation of each mode, refer to the product's instruction manual. Key Functions Moves upward for item selections. Also used to increase values for data entry.