-10AS G46-2-02 G36-2-01 G46-2-02 G46-2-02 G46-2-02 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.
Caution REC25 101110-AS2001F-06-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC32 101110-AS3001F-08-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC40 101110-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 2. Speed control is possible with meter-in and meter-out types of speed controllers.
Recommended speed controller Model Elbow type 10-AS2201F-01-06-X214 10-AS2201F-02-06-X214 10-AS2201F-02-06-X214 10-AS3201F-02-08-X214 10-AS3201F-02-08-X214 Model Straight type 10-AS2301F-01-06-X214 10-AS2301F-02-06-X214 10-AS2301F-02-06-X214 10-AS3301F-02-08-X214 10-AS3301F-02-08-X214 In-line type 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS3001F-08-X214 10-AS3001F-08-X214
Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.
Option Body material Nil N Body only With silencer 1 2 ADC12 (Aluminum) SCS14 (Stainless steel) For AIR EXH: AN200-02 Port size Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Diaphragm material 02 03 1/4 (8A) 3/8 (10A) 1 PTFE (Fluoro resin) JIS Symbol Type Thread
1.02kgf/cm2j -O.1MPa 1MPa 11 O.2kgf/cm2j MPa, PSI kgflcm2. bar Unit setting mmHg, kPa, PSI kgflcm2 , bar MPa:O.01, PSI:1 kgf/cm2:O.1, bar:O.1 Min. setting range mmHg:10, kPa:2, PSI:O.2 kgf/cm2:O.02, bar:O.02 A variety of switch output modes Note1) J HysteresIs mode Adjustable (2digit or more) Adjustable (3digit or more) Applicable to a hysteresis mode, window comparator mode.and reversed
1 Thread size M5 01 02 03 04 M5 x 0.8 R R R R 1 8 1 4 3 8 1 2 M5 port only Note 1) AS221: Electroless nickel plated Note 2) AS221: Steel Note 3) Meter-in type: Black zinc chromated 15-9-8
How to Order Manifolds SS5Q J 2 3 08 D0 N ( 00T) D For P, R port inch sizes Kit designation Plug-in Series VQ2000 1 2 4 3 Option 4 Nil Electrical entry/Cable length Stations 1 2 Note 2) 01 Kit designation Entry direction Standard stations Kit, Cable length 1 station None Specifies DIN rail length Note 2) 02 to 24 B K N R S With back pressure check valve on all stations Special wiring specifications
RL a 2 0.54~0.66Nm) 1 Ass'y P.27 1 2 L POM,POM,PET,SUS 3 R POM,POM,PET,SUS 4 () (PET) P.27 2 5 Assy PBT P.27 3 6 Assy () P.27 7 7 NBR P.27 4 8 NBR P.27 5 9 Ass'y P.27 6 26 - No.ZQ-OM01401-B 7.4 1 Ass'y2 ) ZQ1-SR1-04-A (1) 01 1 (1) 02 2 08 8 2 () (2 ) ZQ1-SE2-A 3 Assy (2 ) ZQ1-SC1-A 4 (10 ) ZQ-3-005-10AS 5 (10 ) ZQ-3-009-10AS 6 Assy (4 ) ZQ1-WS3-A (1) 3 M3 () (1) 4 M4 ()
Port size Symbol Port size Model PSE570 PSE573 PSE574 PSE575 PSE576 PSE577 01 R1/8 (with M5 female thread) 02 R1/4 (with M5 female thread) For pressure switch precautions and specic product precautions, refer to the Operation Manual on the SMC website.
Example) G36-P4-01-X30 Regulator 2 Port Solenoid Valve AR 20 E 02 1 VCA27A S 5 DL 02 4 Q Port size Thread type Voltage CE marked 02 02N 02F Rc 1/4 NPT 1/4 G 1/4 Rc NPT G Nil N F 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Throttle Option (The shape of pressure gauge) Note 2) Nil S B K Without throttle and manual lock With throttle With manual lock With manual lock
th the regulalor a a a a a a a a a a a a a a a a a a o a a a r t a a a a a a a o a a AW With digital pressure switch with display fitf"r r.gut"t;f outDut specificalions (tsE30-01-!!
"-M" ( ) "-M" 13 SI kPaMPa 14 15 () 16 () / ( () ) -29No.PS-OMG0001CN-H OUT1 80mA OUT2 7F.S. 3 ( 4dights ) 1 -30No.PS-OMG0001CN-H PSE3 -100100 kPa 0-101 kPa 0100 kPa 01 MPa 0500 kPa 02 kPa 1 -101101 kPa 10-101 kPa -10100 kPa -0.11 MPa -50500 kPa -0.22 kPa 0.2 kPa 0.1 kPa 0.1 kPa 0.001 MPa 1 kPa 0.01 kPa DC1224 V10P-P10 50 mA() PSE30DC15 V(1 M) PSE31DC420mA100 ) 1 26.4V
Model d T1 T2 H1 H2 D1 D2 L1 L2 L3 L4 A * M ASP330F-01-06S-X369 R1/8 M5X0.8 12 8 14.2 20.4 27.5 13.6 38.6 35.2 13.5 6 11.6 ASP430F-02-06S-X369 25.2 34.4 18.3 16.8 R1/4 17 18.5 48.7 42.4 ASP430F-02-08S-X369 27.2 36.4 18.4 18.5 Rc1/8 12 8 15.2 ASP530F-03-08S-X369 29.7 41.2 18.7 R3/8 19 23 21 56.2 50 ASP530F-03-10S-X369 31.6 43.1 20.8 10 18.5 ASP630F-04-10S-X369 33.6 47.9 25.6 20.8 R1/2 Rc1/
Body size Port size Thread type Nil N F Symbol Port size Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 A spacer or spacer with bracket is required if the valve is combined with modular FRL. SUP SUP Applicable air preparation equipment Spacer with bracket part no. Pressure relief 3 port valve VHS20 VHS30 VHS40 VHS40-06 VHS50 IN OUT Spacer part no.
Option Body material Nil N Body only With silencer 1 2 ADC12 (aluminum) SCS14 (stainless steel) For AIR EXH: AN200-02 Connection port size 1/4 (8A) 3/8 (10A) Diaphragm material 02 03 1 PTFE (fluororesin) Symbol Type of operation Thread type FLUID OUT AIR SUP Nil T F N Rc NPTF G NPT Automatically operated type with built-in pulsation attenuator 2 AIR EXH FLUID IN Built-in pulsation attenuator
Option Body material Nil N Body only With silencer 1 2 ADC12 (aluminum) SCS14 (stainless steel) For AIR EXH: AN200-02 Connection port size 1/4 (8A) 3/8 (10A) Diaphragm material 02 03 1 PTFE (fluororesin) Symbol Type of operation Thread type FLUID OUT AIR SUP Nil T F N Rc NPTF G NPT Automatically operated type with built-in pulsation attenuator 2 AIR EXH FLUID IN Built-in pulsation attenuator
Option Body material Nil N Body only With silencer 1 2 ADC12 (aluminum) SCS14 (stainless steel) For AIR EXH: AN200-02 Connection port size 1/4 (8A) 3/8 (10A) Diaphragm material 02 03 1 PTFE (fluororesin) Symbol Type of operation Thread type FLUID OUT AIR SUP Nil T F N Rc NPTF G NPT Automatically operated type with built-in pulsation attenuator 2 AIR EXH FLUID IN Built-in pulsation attenuator
Panel adapter B ZS-22-02 Thread type Piping port size Rc NPT G Nil N F 01 02 1/8 1/4 Specifications PFA301-m PFA300-m Model Specifications Note 1) 1 to 10, 5 to 50l/min (0.04 to 0.35, 0.18 to 1.77SCFM) Flow rate range measurement & setting Minimum setting unit 1% of maximum flow rate range Model PFA510-m PFA550-m Real-time flow rate l/min, CFM x 10-2 Display units Measured fluids Dry air,