SMC Corporation of America
Elite Part Number Search
Search Results "ZA1071-K15L-P1-54"

} 7 16 104 {110} 10 12 M12 x 1.25 4 M5 x 0.8 12 7 (5.5) 28 14.2 M4 x 0.7 19 6 15 12 48 (53) 7 10.5 16 104 (109) 12 16 M16 x 1.5 6 M5 x 0.8 17 8 (5.5) 38 14.2 5 M6 x 1 24 8 18.3 16 52 (54) 10 9.5 22 128 (130) 16 16 M16 x 1.5 6 M5 x 0.8 17 8 (5.5) 38 14.2 5 M6 x 1 24 8 18.3 16 52 (54) 10 9.5 22 128 (130) 20 20 M22 x 1.5 8 G1/8 20 8 44 17 6 M8 x 1.25 32 11 24 22 62 13 13 24 150 25 22 M22 x

} 104{110} 8 12 12 10.5 M4 x 0.7 M5 x 0.8 M12 x 1.25 4 16.7 15 12 4.5 19 6 10.5 28 16 7 48(53) 104(109) 7(5.5) 11.5(13.5) 10 12 16 14 M6 x 1 M5 x 0.8 M16 x 1.5 6 19.7 18.3 17 5.5 24 5 8 9.5 38 22 10 52(54) 128(130) 8(5.5) 12.5(12.5) 12 16 16 14 M6 x 1 M5 x 0.8 M16 x 1.5 6 19.7 18.3 17 5.5 24 5 8 9.5 38 22 10 52(54) 128(130) 8(5.5) 12.5(12.5) 16 16 22 17 M8 x 1.25 G 1/8 M22 x 1.5 8 28 24

39.5 51.5 42.5 Head end 48 54 46.5 52.5 49.5 55.5 Rod end 64 32 (46) 62.5 30.5 (44.5) 65.5 33.5 80 (47.5) Double end 64 54 62.5 52.5 65.5 55.5 48 54 46.5 52.5 49.5 55.5 Head end Rod end 64 32 (46) 62.5 30.5 (44.5) 65.5 33.5 100 (47.5) Double end 64 54 62.5 52.5 65.5 55.5 Note 1) The values in ( ) are for long stroke.

Model E M H W L 1/8 LQ1U11 LQ1U12 LQ1U21 LQ1U22 LQ1U31 LQ1U32 LQ1U33 LQ1U41 LQ1U42 LQ1U51 LQ1U52 LQ1U61 LQ1U62 4 3 6 4 10 8 6 12 10 19 12 25 19 10 11.5 29 10 Class 1 14 41 14 15 16.5 H W M 17 17 20 54 23 1/4 28 21 21 24 63 (E) (E) Class 2 to 5 77 26 26 29 39 L 102 39.5 36 49 36 M Inch sizes H Applicable tubing O.D.

Model L VXA H M H W E VN LQ1U1A LQ1U2A LQ1U2B LQ1U2C LQ1U3A LQ1U3B LQ1U4A LQ1U4B LQ1U5A LQ1U5B LQ1U6A LQ1U6B 10 11.5 29 10 1/8" 1/4" 3/16" 1/8" 3/8" 1/4" 1/2" 3/8" 3/4" 1/2" 1" 3/4" LVC 16.5 14 41 14 15 25 1 LVA 17 17 20 54 23 Class 6 LVH 28 21 21 24 63 LVD 77 26 26 29 39 (E) shows the approximate dimension of the inserted tubing from the end of the nut.

Maximum load current: 30mA The NPN and PNP digital monitor outputs can be set to function in one of three different ways: comparator mode hysteresis mode self-diagnostic mode when P1P1>=P2 when P1=P2=0 The output is on whenever the outlet pressure is greater than P1 but less than P2. The output comes on once the outlet pressure reaches P1.

How to Find the Flow Rate (at air temperature of 20C) Choke flow: when (P2 + 0.1)/(P1 + 0.1) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t : Air temperature Note) Formulas above apply

How to Find the Flow Rate (At air temperature of 20C) Choke flow: (P2 + 0.1)/(P1 + 0.1) ) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q: Air flow rate [ /min (ANR)] S: Effective area (mm2) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t: Air temperature [C] Note 1) Formulas above are

Subsonic flow at P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P (P2 + 0.1013) Sonic flow of P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) VER2000 Q: Air flow rate [/min (ANR)] S: Effective area [mm2] P: Amount of pressure drop P1 P2 [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Cylinder stroke (st/mm) Correction for varying air temperatures: Square the coefficient

Tighten the orifice again and connect the pilot piping to port P1 using an M5 fitting.

Q=226S P(P2+0.1013) Sonic flow : P1+0.10131.89(P2+0.1013) Q=113S(P1+0.1013) Q : Flow rate [ /min(ANR)] S : Effective area (mm2) P : Pressure differential (P1-P2) [MPa] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] When the air temperature is different, multiply the flow rate calculated with the above formula by the following coefficient for compensation. -20 1.08 -10 0 10 30

Maximum load current: 30mA The NPN and PNP digital monitor outputs can be set to function in one of three different ways: comparator mode hysteresis mode self-diagnostic mode when P1P1>=P2 when P1=P2=0 The output is on whenever the outlet pressure is greater than P1 but less than P2. The output comes on once the outlet pressure reaches P1.

Model B3 C1 14 20 22 C2 39 44 54 E1 1 1 1 E2 1 1 1 B1 28 40 44 78 88 108 96 111 131 MY-J25 MY-J32 MY-J40 8-11-29 29 Series MY1B Floating Bracket Facilitates connection to other guide systems. Applicable bore size Floating Bracket Operating Precautions Caution Make sure that the amount of divergence from the external guide is within the adjustable range.

79 44.5 69.5 54 79 44.5 69.5 24.5(27.5) 24.5(27.5) 19.5 25 25 29 104 94.5 54 79 44.5 69.5 54 79 44.5 69.5 27(30) 27(30) 19.5 129 129 119.5 119.5 32 32 30 105 95.5 55 80 45.5 70.5 55 80 45.5 70.5 30.5(33.5) 30.5(33.5) 20.5 130 130 120.5 120.5 40 40 34.5 109.5 97.5 59.5 84.5 47.5 72.5 59.5 84.5 47.5 72.5 35(38) 35(38) 22.5 134.5 134.5 122.5 122.5 20 20 24 99 89.5 49 74 39.5 64.5 49 74 39.5

C 0.2 C 0.2 B 0.2 B 0.2 A 0.2 A 0.2 D Bore size (mm) A (mm) B (mm) C (mm) Bore size (mm) A (mm) B (mm) C (mm) D (mm) (mm) Hexagon socket head cap screw Hexagon socket head cap screw MGPM MGPL 12 50 50 18 41 10 8 M4 x 0.7 140 50 116 32 M12 x 1.75 16 80 56 22 46 12 10 M5 x 0.8 214 66 170 47 M16 x 2 Connection thread size Proper tightening torque (Nm) a dimension 20 72 24 54 14 12 M5 x 0.8 25

AXT632-54-1 AXT632-54-2 AXT632-54-3 AXT632-54-5 AXT632-54-6 AXT632-54-7 AXT632-54-8 AXT632-54-9 AXT632-54-10 AXT632-54-11 Mounting bolt Size M6 x 45 with SW M6 x 18 with SW M6 x 55 with SW M6 x 85 with SW M6 x 100 with SW M6 x 105 with SW M6 x 125 with SW M6 x 140 with SW M6 x 145 with SW M6 x 160 with SW Option mounting diagram Interface regulator Interface regulator Double check spacer

#1 (#1+#12) CLM2B32SCLM232, #1 (#1+#12) CLM2B40SCLM240, #1 (#1+#12) 3.1-20 Fine Lock Cylinder/Double Acting Single Rod Series CLM2 Axial Foot (L) CLM2L Bore size Stroke CL MLGC CNA CB CV/MVG (mm) CXW BQ BP Bore Stroke range A 18 22 22 24 BC 38 45 45 52 GC 8 9 9 8 GK 3.5 4 4 4 AL 15.5 19.5 19.5 21 BN 80 90 90 F 13 13 13 16 H 41 45 45 50 B1 13 17 17 22 BZ GB 8 8 8 11 GQ 4 7 7 8 B 40 47 47 54

Base mounted (with sub-plate) 53 (32) 58 (37) M5 x 0.8 54 (33) Note) Value for DC. Add 1 g for AC. ( ): Without sub-plate.

AS431FSG1-G04-10 10 1/2 27 15.9 17.4 18.8 25.6 47.9 26.1 61.2 64.1 62.5 55.1 53.5 15.6 26 19 86 AS431FSG1-G04-12 12 18.5 21 26.2 49.8 28.3 63.4 17 90 10.4 12.9 16.6 20.2 36.6 21.4 50.1 13.3 3/8 21 55.4 54 47.9 46.5 24.5 19.2 26 Series AS-FSG Made to Order Please contact SMC for detailed dimensions, specifications and delivery.

53.5 81.5 48.5 MK(2) 25 76 76.5 54 53.5 81.5 48.5 32 92 92.5 57 56.5 97.5 51.5 RS Q G 40 130 130.5 64 63.5 135.5 58.5 Note) D-F7LF type cannot be mounted on bore size 10.