Construction L-Bracket w e r t w e r t q Component Parts No. Description Material 1 Bracket Steel strip DIN Rail Mounting Bracket q o !0 !1 i y u q o !0 !1 i y q w e Component Parts No. Description Material Note 1 Body A PBT 2 Knob POM 3 Body B PBT 4 Needle PBT 5 Needle guide Brass Electroless nickel plating 6 U-seal HNBR 7 Spacer PBT1 Component Parts No.
to 10.5 l/min 2.5 to 52.5 l/min 5 to 105 l/min 10 to 210 l/min 25 to 525 l/min Set flow rate range Note 1) 0.1 l/min 0.5 l/min 1 l/min 2 l/min 5 l/min Minimum set unit Note 1) Accumulated pulse flow rate exchange 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse value (Pulse width: 50 ms) Note 1) Note 2, 3) l/min, CFM x 10-2 l/min, CFM x 10-1 Real-time flow rate Display units l, ft3
Operation description of the soft start-up valve q When the pilot valve q is turned OFF , the pilot air of the spool w is exhausted from the pilot valve q, and the spool w and valve e are returned upward due to the spring. This opens the flow passage to port 3 (R), exhausting the air pressure on the port 2 (A) side.
min (ANR) (SCFM) Note 2) Outlet air flow rate l/min (ANR) (SCFM) Purge air flow rate l/min (ANR) (SCFM) Note 3) Bracket assembly (accessory) part nos.
Union Tee: KPQT, KPGT D 3 x Applicable tubing Effective area mm2 D Model L Applicable tubing O.D. mm Note 1) Weight g M Q TPH TPS 4 L Q M D D KPGT04-00 KPQT04-00 10.4 7 4 4 17 4.5 19.7 6 KPGT06-00 KPQT06-00 12.8 9 10 10 18.5 5.3 21.8 8 KPGT08-00 KPQT08-00 15.2 16 18 26 20.5 6 25.3 4.2 8 10 KPGT10-00 KPQT10-00 18.5 25 29 41 23 6.8 28.4 M M L L 12 KPGT12-00 KPQT12-00 20.9 29 46 58 24 7.5 30.4
How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17
How to find the flow rate for water Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) Q = 0.8 S 10.2 P l/min Q: Flow rate (l/min), P: Pressure differential (P1P2), P1: Upstream pressure (MPa) P2: Downstream pressure (MPa), S: Effective area (mm), Cv: Cv factor 17 Compact Direct Operated Series VDW 2/3 Port Solenoid Valve for Water and Air Safety
XLGV/With solenoid valve Q Port R (exhaust port) N N With double solenoid P K M L (mm) L 6.5 6.5 6.5 11 11 11 K 9 9 9 11 11 11 N 14 Model K L M N P Q M 17 15 2 6 Q 16.5 16.5 17.5 28 29 29 P Model XLGV-16 XLGV-25 XLGV-40 XLGV-50 XLGV-63 XLGV-80 3 3 3 6.5 6.5 6.5 16 With single solenoid Port P (pressure port) 29 26 32 45 Other dimensions are the same as XLG. 19 Series XLD, XLDV Smooth Exhaust
XLGV/With solenoid valve Q Port R (exhaust port) N N With double solenoid P K M L (mm) L 6.5 6.5 6.5 11 11 11 K 9 9 9 11 11 11 N 14 Model K L M N P Q M 17 15 2 6 Q 16.5 16.5 17.5 28 29 29 P Model XLGV-16 XLGV-25 XLGV-40 XLGV-50 XLGV-63 XLGV-80 3 3 3 6.5 6.5 6.5 16 With single solenoid Port P (pressure port) 29 26 32 45 Other dimensions are the same as XLG. 19 Series XLD, XLDV Smooth Exhaust
4 x OB counterbore depth OL L (OL) 4 x NN through U X PW PE VA 2 x P (Plug) H R T 2 x P D GB GC S Q 2 x P (Plug) GA JC PD C + Stroke FB FA K J G A + Stroke [mm] Bore size Standard stroke A C D FA FB G GA GB GC GD H J JC K L MM ML NN Nil TN TF 20 (16 x 2) 20, 30, 50 100, 150 38 27.5 8 7.5 3 22 12.5 7.5 11 83 11 3 11 14 M4 x 0.7 10 M4 x 0.7 25 (20 x 2) 39.5 28 10 8.5 3 26 12 7.5 11 93
AS120M AS220M-01 AS220M-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10 20 50 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 40 30 5 10 20 10 0 5 0 5 20 10 10 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Construction Meter-out type AS1200M AS2200M u w u w t e r !0 !1 i q !4 r e !0 !1 q i !
Modify the detecting position while the auto switch is secured at the position of (3) in the figure. a Auto switch mounting screw M3 x 0.5 x 8 L (For BQ-1) Auto switch Set screw (Unused) r u t c e y Auto switch mounting bracket d Auto switch mounting screw M2.5 x 0.45 x 6 L b Square nut (For BQ-1) w Cylinder q BQ-1 and BMU1-025 are a set of a and b shown above.
10 100 -X Eccentric distance L (mm) 507 MGPW Series L L m m Horizontal Mounting Slide bearing MGPWM20 to 63 (17) L = 50 mm, V = 200 mm/s or less (18) L = 100 mm, V = 200 mm/s or less 100 100 Load mass m (kg) Load mass m (kg) 50, 63 50, 63 50, 63 50, 63 32, 40 32, 40 10 10 32, 40 32, 40 25 25 25 20 25 20 20 20 1 1 10 100 50 51 200 10 100 50 51 200 Stroke (mm) Stroke (mm) (19) L = 50 mm, V
Note 3) Weight without sub-plate 1.12-7 VQZ1000/2000/3000 Body Ported Construction: VQZ1000/2000/3000 Metal seal Rubber seal e w q r e w q r 2 position single 2 position single (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) e w q r e w q r 2 position double 2 position double (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) e w q e w q 4 r 3 position pressure
B RATE PWR L RUN SETTINGS MOD/NET ADDRESS NO. PWR PWR COM ERR ON ON L ERR.
l /min How to find the flow rate for water 5.0 Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min VCB 3 Cv = 0.35 3 4 Formula based on effective area (Smm) 1.0 Q = 0.8 S 10.2 P l/min VCB23 Cv = 0.33 VCB25 Cv = 0.65 Q: Flow rate (l/min) P:Pressure differential (P P) P: Upstream pressure (MPa) P: Downstream pressure (MPa) S: Effective area (mm) Cv: Cv factor VCB34 Cv = 0.54 VCB24
N.O. q IFW50--75/76 e Color of lead wire Black Symbol Contact q w Power supply (Common) w Red Terminal (Relay terminal) 24 VDC Gray e Power supply (Light terminal) N.O. N.C. q IFW50--85/86 e Color of lead wire Black Symbol Contact q w Power supply (Common) White Terminal (Relay terminal) w 24 VDC Gray e Power supply (Light terminal) N.C. N.O.
l /min How to find the flow rate for water 5.0 Formula based on Cv factor Q = 14.2 Cv 10.2 P l/min Formula based on effective area (Smm) VCB 3 Cv = 0.35 3 4 1.0 Q = 0.8 S 10.2 P l/min VCB23 Cv = 0.33 VCB25 Cv = 0.65 Q: Flow rate (l/min) P:Pressure differential (P P) P: Upstream pressure (MPa) P: Downstream pressure (MPa) S: Effective area (mm) Cv: Cv factor VCB34 Cv = 0.54 VCB24
MX MTS MY Centralized piping on right CY MG CX R R L DL -X R L Slide table actuation direction 20Centralized piping on left Data R L L R R L Slide table actuation direction 4. Never disassemble the magnetic component parts (external slider, internal slider) of the actuator (cylinder). If will cause decline of the holding force, etc. 2.
CY1F10 to 25-AAL CY1F10 to 25-AAR L EA approx.