Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 25, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150,
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150,
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150,
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 50, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 50, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: With indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 63, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,
Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 80, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 60,
Magnet: D (Built-in Magnet), Mounting: U (Rod Trunnion), Bore: 40mm, Port Thread: TN (NPT), Stroke: 75mm, Cushion: A (Air Cushion), Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch),