Safety cannot be assured in the case of unexpected malfunction. [ PoS] Orientation [ Hor ] Horizontal mounting [F31] [ Pr S] Supply pressure [ m id] 0.4 MPa minimum, 0.6 MPa maximum Connector pin numbers (lead wire) The accumulated flow has reached the set accumulated flow value.
AL7 T h e r m o s t a t (0.1C) 0.0 Sets lower limit of temp measured by the internal temp sensor and stops operation of the product. 0.0 to 59.0C A H Do not make any modification to the product. Do not disassemble the product, unless required by installation 11 Ambient temperature is too high. (out of 10-35oC) Correct the ambient temperature within the specification range.
Apr R QR RR SR . ZR AR BR . Jul U QU RU SU . ZU AU BU . Month Q R S . Z A B . Oct X QX RX SX . ZX AX BX . T With stand for vertical installation 8 1 15 9 D-sub 15 pin (Socket type) Fixed screw: M2.6 Description No.
connector Connector Z None Standard Stroke Range of manufacturable stroke Standard stroke (mm) Tube Bore(mm) Without Gaiter With Gaiter Without Gaiter With Gaiter 40 25850 25700 1200 950 50 25800 25650 1150 900 63 25800 25650 1150 900 80 25750 25600 1100 900 4-2 Controller 100 25750 25600 1100 850 CEU2 Output Method None NPN Open Collector P PNP Open Collector 16 4-3 Extension Cable CE1-R
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as 3% or less of the rated voltage. 3.
A filtration degree of 5 m or less should be selected. Install an air dryer, after cooler or Drain Catch(water separator), etc. Air that includes excessive drainage may cause malfunction of valves and other pneumatic equipments. To prevent this, install an air dryer, after-cooler, or water separator, etc.
If a current of more than 3.1 A can not be avoided, supply the power to the Power block and SI unit (solenoid valve manifold) by separate cables. -53No.EX-OMH0025-C (2)EX500 series for use with Output block Details of EX500 series suitable for use with the Output block. : Only VQC series solenoid valve is applicable. (3)End plate (Intput side) (4)End plate R (Output side) Details of the end
Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be 3% or less of the rated voltage. 7.
CJ1 CJP CJ2 CM2 C85 Component Parts CG1 No. q w e r t y No. u i o !0 !1 !
2 r!4 i yq !3t!8!1!7w !6ui e!5 CJ1 CJP CJ2 CM2 C85 !
port thread type Series 3 SYA3000 5 SYA5000 Nil Rc G F 40 SYA 7 1 Base mounted N NPT NPTF T P, R port thread type Type of actuation Nil Rc 2 position single G F Port size 1 N NPT Symbol Applicable series Nil Port size Without sub-plate NPTF T 2 position double 1 8 01 SYA3000 Port size With sub-plate 2 Symbol Nil Port size Without sub-plate Without sub-plate (Pilot port: Expect RC) 1 4 With
Fitting Type: H (Connector), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 5E (Tube O.D. 3/4", Tubing Size 3/8"x1/4"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)
Fitting Type: H (Connector), Metric Size, Side A: 4F (Tube O.D. 1/2", Tubing Size mm 3x2), Inch Size, Side A: No (Select Metric Size, Side A), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)
Fitting Type: H (Connector), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 5F (Tube O.D. 3/4", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)
Fitting Type: H (Connector), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 4E (Tube O.D. 1/2", Tubing Size 1/4"x5/32"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: M (Male)
Size: 100, Motor Mounting Position: R (Right Side Parallel), Motor Type: T9 (AC Servo Motor, Absolute Encoder), Lead: L (2mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread), Mounting: D (Double Clevis), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Driver Type: B2 (LECSB2-T9/Pulse Input, 200V to 240V), I/O Cable Length: 1 (1.5m
PEND Specifications Water/Non-corrosive liquid Fluid 0.1 to 0.6 MPa Operating pressure Water resistance 1.2 MPa 5 to 60C (No freezing) Operating temperature range Operation Diaphragm style 100 M (500 DC by megameter) Insulation resistance Withstand voltage 1500 VAC for one min.
N.C. 125 AC 250 AC 30 DC 125 DC 1.3 0.8 2.5 1.5 0.7 0.5 1.5 1 3 0.05 2 0.05 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 1500 VAC, Hz for 1 min.
Material Cast iron Undercover Body Plated Cast iron Aluminum alloy w e Cover Plate r Iron t Stainless steel Valve element A Valve element B Piston Return spring y Stainless steel u Aluminum alloy i Piano wire o Stainless steel Valve seat !0 Stainless steel Rod !1 Stainless steel Parallel pin !2 Refer to How to Order in page 17-4-32. Pilot solenoid valve 17-4-36
M 1 2 x 1 Cable connection threads suP (1) 2-Ro(PT) 114,318, 1/2 Port size Mounting hole L-bracket tNt-398-0-6 (optional) 2-Rc(PT) 1/4,3/8, 1/2 SUP port, OUT port Eleclno-Pltoulnalic Relulatnn rTUz000/3 lt'iler ilile $ruciliciliotts 2 through I station manifold.