Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: w/o Lead Wire, Bracket: Bracket C, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: w/o Lead Wire, Bracket: Bracket C, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Rc1/8, Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Rc1/8, Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: B2 [TSJ1/4 (Compression Fitting)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: w/o Operation Manual

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover,

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Operation Manual: Operation Manual, Calibration

Series IR Precision Regulators are designed to be compact and light weight. The maximum set pressure has been expanded from the conventional 0.7MPa to 0.8MPa. Relief flow has been increased by nearly 5 times (compared to SMC IR201, IR401). The optio, REGULATOR, REGULATOR, PRECISION, 813, 0.47 lb

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

Note 4) 1 m (M): D-M9(W)(V) only Model Lead wire length D-LC05 0.5 m D-LC30 3 m D-LC50 5 m Lead wire length Tolerance 15 mm 0.5 m 30 mm 1 m 90 mm 3 m 150 mm 5 m 1728 Solid State Auto Switch Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) Refer to SMC website for the details of the products conforming to the international standards.

) a = 3000 2000 m L1 0 10 20 30 Transfer load m (kg) L2 600 400 L2 (mm) Mer Rolling Yawing m 200 L2 Mer 10 20 30 0 Transfer load m (kg) m a = 1000 4000 a = 2000 L3 (mm) L3 a = 3000 2000 m Mey a 10 20 30 0 Transfer load m (kg) Refer to page 183 for deflection data. 164

1 m 1.5 m 2 m 3 m 5 m 0.5 m 1 m 1.5 m 2 m 3 m 5 m Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.

Point of application L (mm) Point of application L (mm) Work piece transfer speed Distance of work piece drop A V (m/min) H (m/min) Coefficient of friction between the work piece and conveyor Gravitational acceleration g (m/s2) Transfer speed V Point of application L Procedure2 Confirmation of impact 1.

H MM NN MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M 10 M5 x 0.8 M3 x 0.5 10.5 16 M6 x 1.0 M4 x 0.7 11.5 20 M8 x 1.25 M5 x 0.8 13.5 25 M10 x 1.25 M6 x 1.0 16.5 30, 40 M14 x 1.5 M8 x 1.25 22.5 Clevis pin d Dd9 m m l t L t Applicable bore size (mm) Applicable snap ring Part no.