Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore Size: 40mm, Port Thread: Rc, Stroke A: 150mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the
Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore Size: 40mm, Port Thread: TN (NPT), Stroke A: 50mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None
Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore Size: 25mm, Port Thread: Rc, Stroke A: 75mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore Size: 25mm, Port Thread: Rc, Stroke A: 100mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore Size: 40mm, Port Thread: Rc, Stroke A: 25mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: 0, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired
Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore Size: 40mm, Port Thread: Rc, Stroke A: 25mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: 0, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case
Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore Size: 25mm, Port Thread: TN (NPT), Stroke A: 50mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore Size: 25mm, Port Thread: Rc, Stroke A: 150mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore Size: 32mm, Port Thread: Rc, Stroke A: 125mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal,
Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore Size: 32mm, Port Thread: Rc, Stroke A: 125mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: A (Air Cushion), Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the
Air Regulator Series AR-B have been updated to the new urban white base color for a clean modern look. The AR-B series has a maximum set pressure of 125 psi and offers embedded gauge and pressure switch options not found in the AR-A while maintaining panel mounting interchangeability with the previous AR models. The locking adjustment knob prevents accidental setting changes.
Auto switches / Proper mounting position for stroke end detection A B Proper mounting position (mm) Bore size A B 40 63 100 32.5 0 16 0 27.5 0 Note) The above mentioned values are indicated as a guide for auto switch mounting position for stroke end detection.
The maximum piston speed for retraction is approximately 70% that of extension. 848 Dual Rod Cylinder/Compact Type CXSJ 2122CXSJ/ 1112Auto Switch Proper Mounting Positions (Detection at Stroke End) CXSJ6 / CXSJ6 11122122D B (mm) D-M9 23 (24) 2 (1) 13 (11.5) 8 (9) D-A93 19 (20) 14.5 (15.5) 6.5 (7.5) Symbol A B C D Note 1) A C Note 1) The above mentioned values are indicated as a guide for
FKM Needle Needle guide Stainless steel 316 Stainless steel 316 Body B Stainless steel 316 3 Series ASG Dimensions ASG22F-M5 H L4 (Width across flats) Applicable tubing O.D. d A L6 D L5 M L3 L1 T L2 ASG32F-01 ASG42F-02 ASG52F-03 ASG62F-04 H (Width across flats) L4 Applicable tubing O.D. d L6 A D L5 M T L1 L3 L2 Max.
Dimension AVL2000 to AVL5000 Soft start up valve with lock out AVL2000/3000/4000/5000 (mm) Port size A B Model C D E F G H Lockable soft start valve. Gradual increase of supply pressure and rapid exhaust of system air when the supply is shut off.
Auto Switch Proper Mounting Position (Detection at Stroke End) A B Proper Mounting Position (mm) Bore size A B 40 63 100 32.5 0 16 0 27.5 0 Note) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.
Y (EX245-DX1)(EX245-DY1) Y 2 PCA-1557785 Y (2M12 M12) A A A . 10-2 Y (PCA-1557785) 64 No.EX-OMU0020CN PCA-1557798 Y (2M8 M12) A . 10-3 Y (PCA-1557798) 65 No.EX-OMU0020CN 10.3.
Thermo-chiller Air-cooled 200 V Type Inverter Type (UL Standards) RoHS HRSH Series How to Order A 20 HRSH 250 Cooling capacity Option 100 10.5 kW 150 15.7 kW 200 20.5 kW 250 25 kW 300 28 kW Nil None A With caster adjuster-foot B With earth leakage breaker B1 With earth leakage breaker with handle K Note 1) With uid ll port S Note 2) Conforming to CE/UL standards Cooling method A Air-cooled
+ Stroke A + Stroke FA FB S HR E b a With front lock XAH7 c d e MO XB T-slot dimensions (mm) DM HN XAH7 XC XL Bore size (m) a b c d e End lock mechanism (locking type manual release ) 6.5 10.5 5.5 3.5 9.5 32 Section XX detailed diagram 6.5 10.5 5.5 4 11 40 8.5 13.5 7.5 4.5 13.5 50 11 17.8 10 7 18.5 63 LL With rear lock (mm) Standard strokes (mm) Bore size (mm) ML NN OA B C DA FA FB G GA GB
As shown in the figure below explaining the dual stroke cylinder functions, in the first stage, the stroke that can be operated when port A is pressurized is the A stroke.
In the second stage, as the piston rod is already operating the A stroke, the stroke that can be operated by pressurizing port C is the B-A stroke.