Series AM can separate and remove oil mist in compressed air, which is difficult to remove by ordinary air filters and removes solid particles such as rust or carbon of more than 0.3 micron. It is the most suitable for air sources that drive pilot, metal seal solenoid valves. Mist separator, possible modular connection, Dust filtration, oil mist separation , Nominal filtration rating: 0.3
MIST SEPARATOR, MIST SEPARATOR, 109, 0.55 lb
MIST SEPARATOR, MIST SEPARATOR, 109, 0.55 lb
MIST SEPARATOR, MIST SEPARATOR, 111, 0.55 lb
MIST SEPARATOR, MIST SEPARATOR, 111, 0.55 lb
MIST SEPARATOR, MIST SEPARATOR, 109, 0.55 lb
MIST SEPARATOR, MIST SEPARATOR, 111, 0.55 lb
IP 1 1 32 TM MAC EtherNet/IP NPN NPN NPN NPN PLC Programmable Logic Controller PNP PNP PNP PNP TM QuickConnect SI Serial Interface Unit PLC U EX600 ( SI FAIL SAFE CLEAR/HOLD/ON ( GND GND () (H.T.)
U U Side The side connected to the solenoid valve when the product is connected to a manifold. -9No.EX-OMO0027-A Assembly Assembling the unit as a manifold : If the unit was purchased as a manifold, the work described in this section is not necessary. (1)Connect a unit to the end plate. Digital and Analogue I/O units can be connected in any order.
IP 1 1 32 MAC PROFINET NPN NPN NPN NPN PLC Programmable Logic Controller PNP PNP PNP PNP SI Serial Interface UnitPLC U EX600 PLCSTOPEX600 PROFINETEX600 GND GND (PLC )bps(bit per second) () (H.T.)
U U Side The side connected to the solenoid valve when the product is connected to a manifold. 9 EX## OMS1015-A Assembly Composing the unit as a manifold : If the unit was purchased as a manifold, the work described in this section is not necessary. (1) Connect the unit to the end plate. The Digital unit, Analog unit can be connected in any order.
U U Side The side connected to the solenoid valve when the product is connected to a manifold. -9No.EX-OMY0026 Assembly Composing the unit as a manifold : If the unit was purchased as a manifold, the work described in this section is not necessary. (1) Connect the unit to the end plate. The Digital unit, Analogue unit can be connected in any order.
U Function to change the unit in which the value of flow is displayed. Only a product with this function can change the unit. A product with unit selection function cannot be purchased if it is used within Japan. Flow is indicated only by SI units in Japan.
U Function to change the unit in which the value of flow is displayed. Only a product with this function can change the unit. A product with unit selection function cannot be purchased if it is used within Japan. Flow is indicated only by SI units in Japan.
U Function to change the unit in which the value of flow is displayed. Only a product with this function can change the unit. A product with unit selection function cannot be purchased if it is used within Japan. Flow is indicated only by SI units in Japan.
U Unit selection function A function to select display units other than the international unit (SI unit) specified in the new Japanese measurement law. Flow can only be displayed by SI units in Japan. W A momentary steep pressure increase due the spread of pressure by closing a contactor such as a valve for an extremely short time while there is a flow.
2.7 10 28 7 S T PF3W704S 56.5 22 PF3W720S 60.5 22 PF3W740S 78 30 -84No.PF-OMM0004-D PF3W704/720/740(+) A AA D K S PF3W704S--T 115 50 81.2 69.5 67.5 PF3W720S--T 123 54 85.2 73.5 71.5 PF3W740S--T 153 71 105.5 90 89 -85No.PF-OMM0004-D PF3W711-U25/PF3W721-U30(PVC ) A B D E F J K L N P Q 25 A 154 46 77 57.6 23 77 63 28 18 3.5 14 32 30 A 146 56 91 71.6 28.5 73 60.5 25 27.5 3.5 14 38 S T U
U Unit selection function A function to select display units other than the international unit (SI unit) specified in the new Japanese measurement law. Flow can only be displayed by SI units in Japan. W A momentary steep pressure increase due the spread of pressure by closing a contactor such as a valve for an extremely short time while there is a flow.
U Unit selection function W Water hammer Water hammer or impact pressure is a pressure surge due to pressure spread when a fluid in motion is forced to stop or change direction when equipment such as valve, is opened/closed. Withstand pressure Burst pressure at which the product is electrically or mechanically damaged.
HRX-OM-O021-U Operation Manual InstallationOperation Original Instructions Thermo chiller Air-Cooled Water-Cooled refrigerated type refrigerated type HRS050-A-20HRS050-W-20Keep this manual available whenever necessary 2020 SMC CORPORATION All Rights Reserved To the users Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).