(Circuit example) 0V 24VDC The stop is released switch Ry Stop Switch U Surge suppressor Ry: Relay Power supply plug 1 LK RLS (6) Ry (3) EMG (2) M 24V (1) C 24V Controller 0V (4) Input power 24VDC supply 0V Power supply plug 2 Ry (3) EMG LK RLS (6) (2) M 24V (1) C 24V Controller 0V (4) Input power 24VDC supply 0V Power supply plug 3 LK RLS (6) Ry (3) EMG (2) M 24V Controller (1) C 24V 0V
(Circuit example) 0V 24VDC The stop is released switch Ry Stop Switch Surge suppressor Ry: Relay U Power supply plug 1 LK RLS (6) Ry (3) EMG (2) M 24V Controller (1) C 24V 0V (4) Input power supply DC24V 0V Power supply plug 2 LK RLS (6) Ry (3) EMG (2) M 24V Controller (1) C 24V 0V (4) Input power supply DC24V 0V Power supply plug 3 LK RLS (6) Ry (3) EMG (2) M 24V Controller (1) C 24V 0V
Lead wire with connector ZS-38-4L 4 cores for 2 outputs, 2 m Lead wire with connector + connector cover ZS-38-3G 3 cores for 1 output, 2 m Lead wire with connector + connector cover ZS-38-4G 4 cores for 2 outputs, 2 m Lead wire with connector for copy function ZS-38-5L 3 cores (for copy function), 1 m Lead wire with connector unit for copy function ZS-38-U for copy function (10 copy destinations
(Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Nil Without cable Sensor cable (3 m) M5 Port size L M5 x 0.8 Option Sensor cable (3 m) + Connector (1 pc.) When only optional parts are required, order using the part numbers listed below.
Note 2) Fixed unit: kPa Supply valve/Release valve combination With supply and release valves With supply valve K1 K2 Output specifications Rated voltage (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) Electrical entry DC specifications 5 6 V S R 24V 12V 6V 5V 3V G H L LN LO M MN MO Lead wire length 0.3 m Grommet Lead wire length
Lead wire with connector ZS-38-3L 3 cores for 1 output, 2 m Lead wire with connector ZS-38-4L 4 cores for 2 outputs, 2 m Lead wire with connector + connector cover ZS-38-3G 3 cores for 1 output, 2 m Lead wire with connector + connector cover ZS-38-4G 4 cores for 2 outputs, 2 m Lead wire with connector for copy function ZS-38-5L 3 cores (for copy function), 1 m Lead wire with connector unit
Other than positioning mode: Actuator travel distance at 10 [m/pulse] per pulse. Positioning Mode: Minimum actuator travel distance of 1[m]. *4 For built-in intermediate supports, the return to origin of stopper type can not be used.
40 80 50 50 20 20 Load mass m (kg) Load mass m (kg) Load mass m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
DXT170-71-1 Coil Coil RS H A M type Cover RZQ 2.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .55115 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .54835 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .66138 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DA, ISE40/50/60 1/4 PT VERSION, .57096 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?