Body Size: 20, Thread: F (G), Port Size: 01 (1/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: Standard, Semi-Standard 1: 2J (2 + J), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: Standard, Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Bracket), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: F (G), Port Size: 01 (1/8), Option: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 20, Thread: F (G), Port Size: 01 (1/8), Option: B (Bracket), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Bracket), Semi-Standard 1: 2J (2 + J), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Stations: 01 (1 Station), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
Stations: 01 (1 Station), Piping: B (U Side: Open; D Side: Open), Thread Type: F (G), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Model: 31, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: C (Conduit), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier), Bracket: B (Bracket)
Model: 31, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: V (C37, Seals: FKM, Class B, Oil-free), Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Model: 31, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: V (C37, Seals: FKM, Class B, Oil-free), Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Model: 31, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: V (C37, Seals: FKM, Class B, Oil-free), Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Surge Suppressor: S (w/Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Model: 31, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier)
Model: 31, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier)
Model: 31, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 2 (200VAC 50/60HZ), Electrical Entry: D (DIN Terminal), Surge Suppressor: L (w/Light), Rectifier: R (AC Class B Coil w/Full-wave Rectifier)
Model: 31, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 4 (220VAC 50/60HZ), Electrical Entry: G (Grommet), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier)
Model: 31, Orifice: 2 (2.2mm), Style: 2 (N.O., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)