Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: Standard, Attachment: T (T-Interface), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: B (Bracket), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Standard
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: Standard, Attachment: KSTV (K + S + T + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: CG (C + G), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: S (Pressure Switch), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Series: SV4000, Function: 2 (2 Position Double), Pilot: Internal Pilot, Voltage: 5 (24VDC), M12 Waterproof Connector: W1 (300), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Driver Operation Manual Button), Port Size: 04 (1/2), Thread: N (NPT)
Actuation Type: 2 (2 Position Double), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: W (IP65 Protection Compatible), 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2)
Function: 2 (2 Position Double), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: F (G)
Function: 2 (2 Position Double), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: N (NPT)
Function: 2 (2 Position Double), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: B (Bottom), Port Size: 04 (Sub-plate 1/2), Thread: N (NPT)
Body Size: 40A, Thread: N (NPT), Port Size: 04 (1/2), Option: DG (D + G), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: C (N.C. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Function: 2 (2 Position Double), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2)
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: DG (D + G), Attachment: T (T-spacer), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Function: 2 (2 Position Double), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)