Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating) / Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 30mm, Option: M (Rod End Male Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5m
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 20mm, Option: M (Rod End Male Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5m
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 150mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 15mm, Option: C (Rubber Bumper)
Magnet: D (Built-in Magnet), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 10mm
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 200mm, Option: C (Rubber Bumper), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5m, Lead Wire or Prewired Connector: M (1m)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 25mm, Option: Standard (Rod End Female Thread), Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical
Magnet: D (Built-in Magnet), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 30mm, Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)
Magnet: D (Built-in Magnet), Mounting: B (Through-hole/Both Ends Tapped Common, Standard), Bore Size: 25mm, Stroke: 10mm, Body Option: Standard, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order Option: XB24, High Durability
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 20mm, Option: Standard (Rod End Female Thread), Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 50mm, Option: Standard (Rod End Female Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in Magnet), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 5mm, Option: C (Rubber Bumper)
Magnet: D (Built-in Magnet), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 150mm, Option: C (Rubber Bumper)
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT LONG STK, ACTUATOR, CQS COMPACT CYLINDER, GE, 16MM CQS DBL-ACT AUTO-SW, .66138 lb
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT LONG STK, ACTUATOR, CQS COMPACT CYLINDER, GE, 16MM CQS DBL-ACT AUTO-SW, .66138 lb
Load voltage Internal voltage drop (illuminated load current load when ON) range AC DC 24V or less 50mA Relay D-A90 AC DC 48V or less 40mA Not provided PLC D-A90V IC circuit AC DC 100V or less 20mA D-A93 2.4V or less (up to 20mA) 3V or less DC24V 5 to 40mA D-A93 Provided Relay (up to 40mA) D-A93V PLC D-A93V 2.7V or less AC100V 5 to 20mA 2.7V or less D-A96 D-A96V DC4 to 8V 20mA 0.8V or less