Magnet: D (Built-in), Rod Type: Standard, Mounting: B [Through Hole (Standard)], Bore Size: 50mm, Stroke: 10mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector)

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

Magnet: D (Built-in), Series: J2, Mounting: F (Rod Flange), Bore Size: 6mm, Stroke: 15mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Bore Size: 20mm, Opening & Closing Stroke: Middle Stroke, Body Option: Axial Direction Ported, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, 0.5M, Lead Wire or Prewired Connector: 1.0m Cord Length, M8-3 Pin Connector, Number: 2 pcs (Or None in the Case of No Switch), Option: With an Adjustable Opening/Closed Finger Positioning, Stroke Adjustable Side: Closed Side, Stroke

Cylinder (Tube) Inner Diameter(φ): 6", Stroke(mm): 12", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9PV, Lead Wire Length(m): 1, The number of the switches: 2, Type of Auto Switch Mounting: APC, Custom-made Specifications: Oversized rod cylinder

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.12~0.7, Cushion: Rubber cushion, Auto Switches: M9PV, Lead

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 6", Stroke(mm): 12", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9PV, Lead Wire Length(m): 1, The number of the switches: 2, Type of Auto Switch Mounting: APC, Custom-made Specifications: Oversized rod cylinder

Gripper ID: 20mm, Action: D (Double Acting), Rotation Angle: 90°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw. Lead

Gripper ID: 20mm, Action: D (Double Acting), Rotation Angle: 180°, Switch at Gripper: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, Gripper Sw. Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector), Number Switch at Gripper: 2 pcs. (Or None in the Case of No Switch), Switch at Rotation: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Rotation Sw.

Series: NCDA1 (Standard w/ Magnet), Mounting: F (MF1, Front Flange), Bore Size: 250 (2 1/2"), Stroke: 4000 (40"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector), Number

Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: TN (NPT), Stroke: 400mm, Option: N (w/o Cushion), Cylinder Switch Type: M9PV--Solid State , Gen. Purpose, 3 Wire PNP, Vertical, 0.5M, Lead Wire or Pre-wired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector),

Bore Size: 40mm, Port Type: TN (NPT), Stroke: 50mm, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector)