Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC 3 PORT SOLENOID VALVE. Direct Op 3 Port Solenoid Valve, N.C.. 840.00000 lb. K44.
Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC 3 PORT SOLENOID VALVE. Direct Op 3 Port Solenoid Valve, COM. 610.00000 lb. K44.
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C 4/5 PORT SOLENOID VALVE. 1000 SERIES 5 PORT VALVE. 40.00000 lb. VVD.
Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1 Cylinder. 0.32000 lb. 333.
Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1 Cylinder. 0.60000 lb. 335.
Model: 10 (200 L/min [ANR]), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 2 (Voltage Style 0~5VDC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: Rc(PT), Port Size: 1 [1/8 (1000)], Accessory: C (L Bracket), Cable Connector: N (w/oCable Connector), Pressure Display Unit: 4 (PSI)
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200
Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size *: 125, 140, 160, 180, 200, Standard stroke *: 10 through 300, Port thread types: Rc, NPT, G, Auto switch capable COMPACT CYLINDER. Compact Cylinder, CQ2-Z. 439.00000 lb. 493.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1 Cylinder. 1.46000 lb. 335.
Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1 Cylinder. 1.07000 lb. 335.
Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1 Cylinder. 0.73000 lb. 335.
Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1 Cylinder. 2.56000 lb. 335.
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Series: 11-LEFS (Clean Series Ball Screw Drive), Accuracy: Basic Type, Size: 25, Motor Type: T6 (100W Output, Absolute Encoder), Lead: A (LEFS25, 12mm; LEFS32, 16mm; LEFS40, 20mm), Stroke: 100mm, Motor Option: B (w/Lock), Vacuum Port: Left, Actuator Cable Type: R [Robotic Cable (Flexible Cable)], Actuator Cable Length: 5 (5m), Driver Type: 92 (LECSN2-T-9, 200~240V, Absolute, EhterNet/IPâ„
Series: NCA1 (Standard), Mounting: C (MP4, Single Detachable Rear Clevis), Bore Size: 200 (2"), Stroke: 0500 (5"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C VQZ1000 VALVE, SOL 4/5-PORT.
Cooling Capacity: 012 (1.2 kW), Power Supply: W2 (200 to 240 VAC), Pipe Thread: N (NPT), Feet: E (w/Feet and No Rack Mounting Brackets), Flow switch: F (w/Flow Switch), Tank with Diagonal Fill Port: Nil (Standard Fill Port), High-pressure pump: P (High Pressure Pump Mounted)